Fixtures & Water HeatersPregunta 83 de 120
A residence has a pressure reducing valve with a check on the incoming water service, and the 40 gallon water heater's relief valve has begun weeping each evening. What is the most likely cause and the correct correction?
a.Thermal expansion in a closed system; install an expansion tank sized for the system
b.The relief valve is set too high; replace it with a 250 degree F valve
c.The heater is oversized; reduce the thermostat to 90 degrees F
d.The discharge line is too long; shorten it and add a threaded cap
Explicación
A check or pressure reducing valve makes the system closed, so water expanding as it heats has nowhere to go and pressure rises until the relief valve lifts, which is corrected with a properly sized thermal expansion tank. Replacing the relief valve with a higher setting defeats the safety device rather than solving the pressure problem. Lowering the thermostat to 90 degrees F creates a bacterial growth risk, and capping the discharge line is expressly prohibited.
Practica las 120 preguntas gratis — sin registro.
Preguntas relacionadas de este tema
- A showerhead is rated at the maximum allowable flow. A user showers for 8 minutes. Assuming the head flows at its rated maximum, how much water is used?
- A public restroom is fitted with metering faucets. What is the maximum volume of water each faucet may deliver per metering cycle?
- A closet flange is set on a wood subfloor before the finished tile is installed, and the installer plans to seal the closet to the flange. Which practice is correct?
- A restaurant installs a grease interceptor sized for 30 minutes of retention. If the connected fixtures produce a peak flow of 25 gallons per minute through the flow control device, what liquid capacity does the retention rule call for?
- A grease interceptor is inspected and found to contain accumulated grease and settled solids filling 25 percent of the total liquid depth. What action does the common maintenance standard require?
- A three compartment pot sink and a food prep sink are being connected in a commercial kitchen. How must the waste from food handling equipment such as a food prep sink be connected to the drainage system?
Última revisión: · proceso editorial
Equipo Editorial de PrepPass · Verificado con Journeyman Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos