Systems & CodePregunta 53 de 110

An oil-water separator serves three garage floor drains each rated at 20 gpm. The code allows sizing at 75 percent of the total connected flow for diversity. What design flow sizes the separator?

a.45 gpm
b.30 gpm
c.60 gpm
d.80 gpm

Explicación

Total connected flow = 3 x 20 = 60 gpm, and at 75 percent diversity the design flow is 60 x 0.75 = 45 gpm. The separator must be large enough to let oil rise and separate before the water passes on to the sewer. Undersizing lets oil carry through and creates an explosion hazard in the sewer.

Referencia Legal: UPC §705.0

Practica las 110 preguntas gratis — sin registro.

Preguntas relacionadas de este tema

Última revisión: · proceso editorial

Equipo Editorial de PrepPass · Verificado con Master Plumber Licensing Exam (UPC/IPC-based) · Cómo revisamos