Gas & FuelPregunta 62 de 110

Appliance venting is classified by category. A Category I appliance is best described as which of the following?

a.Positive vent pressure, non-condensing
b.Negative vent pressure, non-condensing (draft hood or fan-assisted, standard flue)
c.Positive vent pressure, condensing
d.Negative vent pressure, condensing

Explicación

A Category I appliance operates with a non-positive (negative) vent pressure and a non-condensing flue, so it uses a conventional type B vent or masonry chimney with natural or fan-assisted draft. Category IV is positive-pressure and condensing, requiring sealed plastic venting. Matching the vent material and pressure rating to the category is essential to avoid condensation damage or spillage.

Referencia Legal: IFGC §503.0