Around a new window, the correct flashing sequence to integrate with the WRB is generally:
a.Head flashing first, then jambs, then sill
b.All four sides at once with sealant only
c.Sill flashing first, then jambs, then head flashing lapped over the WRB above
d.Only the head needs flashing
Giải thích
The proper shingle-lap sequence is sill pan flashing first, then jamb flashing over the sill, then head flashing with the WRB above lapping over the head flashing, so each layer sheds onto the one below. Doing the head first, all at once with sealant, or head-only all trap water.
Trích dẫn luật: 2025 CA Building Code / CRC (Weather Protection)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- CALCULATION: A wall assembly has three layers with R-values of R-4 (sheathing), R-13 (cavity), and R-0.68 (interior finish). Ignoring air films, what is the total nominal R-value?
- An air barrier is installed in a building envelope MAINLY to:
- A water-resistive barrier (WRB) is being installed over wall sheathing. To shed water correctly, the horizontal laps must be arranged so that:
- Behind exterior stucco or siding, a drainage gap or weep provision is often required so that:
- Fiberglass batt insulation is compressed and stuffed tightly around wiring and into a cavity that is too shallow. The effect on thermal performance is:
- In a mixed California climate, a vapor retarder placed on the WRONG side of the insulation can cause: