Planning & EstimatingCâu 499 / 700
On a foundation inspection, you see anchor bolts set roughly 8 ft apart with the nearest bolt about 20 inches from the end of each sill plate section. Based on typical residential requirements, what is the MOST likely deficiency?
a.Bolts are spaced too closely and there are too many
b.The bolt diameter is the only concern
c.Spacing exceeds the maximum and end bolts are set too far from the plate ends
d.Anchor bolts are not required for wood sill plates
Giải thích
Typical residential requirements limit sill-plate anchor bolt spacing to a maximum of about 6 ft on center, with a bolt located within about 12 in of each end of a plate section. Bolts at 8 ft spacing exceed the maximum, and an end bolt 20 in from the end is too far. Options a and d are incorrect; option b overlooks the spacing and end-distance failures that matter most here.
Trích dẫn luật: 2025 California Residential CodeLuyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A framing plan shows interior stairs with 8.5 inch risers and 9 inch treads. Compared with typical residential code limits, what is the MOST likely problem an estimator or inspector should flag?
- A subcontractor submits shop drawings for structural steel connections. What is the general contractor's PRIMARY responsibility when reviewing them?
- The written specifications call for Type X gypsum board, but the plan detail simply notes '5/8 in drywall.' In the contract documents, how are such conflicts typically resolved?
- You are preparing a critical path schedule. Which sequence of activities BEST reflects proper project coordination for a slab-on-grade building?
- A concrete slab is 30 ft by 40 ft and 4 inches thick. How many cubic yards of concrete are required?
- A bedroom plan shows a single egress window with a clear opening of 5.0 square feet and a sill 46 inches above the finished floor. Based on typical emergency escape requirements, what should the plan checker flag?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra