Planning & EstimatingCâu 502 / 700

A bedroom plan shows a single egress window with a clear opening of 5.0 square feet and a sill 46 inches above the finished floor. Based on typical emergency escape requirements, what should the plan checker flag?

a.The sill height exceeds the maximum and the clear opening is below the minimum
b.Nothing; bedrooms do not need egress windows
c.Only the glass type matters
d.The window is oversized and should be reduced

Giải thích

Emergency escape and rescue openings in sleeping rooms generally must provide a minimum clear opening of about 5.7 square feet (5.0 sq ft is allowed only at grade-floor openings) with a sill no more than 44 inches above the floor. A 46 in sill exceeds the maximum, and 5.0 sq ft is short for an above-grade room. Options b, c, and d misstate or ignore the life-safety requirement.

Trích dẫn luật: 2025 California Residential Code

Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra
Báo lỗi