Cơ sở, Vệ sinh & Côn trùngCâu 491 / 50064% thí sinh trả lời sai câu này

A manager verifies that a high-temperature dish machine actually sanitized a rack. What measurement confirms it?

a.A dial thermometer reading 180°F inside the wash tank
b.An irreversible indicator showing a 160°F utensil surface
c.A test strip showing 50 mg/L on a plate pulled from the rack
d.A gauge on the machine reading 25 pounds per square inch

Giải thích

Hot water mechanical sanitizing is confirmed by achieving a utensil surface temperature of 160°F as measured by an irreversible registering temperature indicator, often a maximum-registering thermometer or a heat-sensitive tape run through with the rack. The machine's own gauges describe the water, not the plate.

Trích dẫn luật: FDA Food Code §4-703.11