Wiring Methods & Materials

A location where combustible dust is present in ignitible concentrations is classified as which type?

  • a.Class IV
  • b.Class II✓
  • c.Class I
  • d.Class III

Class II locations are those made hazardous by combustible dust. Class I covers flammable gases and vapors and Class III covers ignitible fibers and flyings. See NEC 500.5(C).

Wiring Methods & Materials

A 15-ampere, 125-volt receptacle is installed in a damp location such as under a roofed open porch. What cover is required?

  • a.A cover that is weatherproof when no attachment plug is inserted✓
  • b.A cover that is weatherproof whether or not a plug is inserted
  • c.No cover is required in a damp location
  • d.A standard indoor wall plate

In damp locations a receptacle needs an enclosure weatherproof when a plug is not inserted; the stricter in-use cover, weatherproof with a plug inserted, is required in wet locations. See NEC 406.9(A).

Wiring Methods & Materials

Receptacles installed outdoors in wet or damp locations must be which listed type?

  • a.Twist-lock
  • b.Weather-resistant✓
  • c.Hospital-grade
  • d.Isolated-ground

Fifteen- and 20-ampere, 125- and 250-volt receptacles in damp or wet locations must be listed weather-resistant. See NEC 406.9(A) and 406.9(B).

Wiring Methods & Materials

Which of the following is a recognized equipment grounding conductor?

  • a.Electrical nonmetallic tubing
  • b.Rigid metal conduit installed under its article✓
  • c.A nonmetallic pull string
  • d.Rigid PVC conduit

Metal raceways such as rigid metal conduit, intermediate metal conduit and EMT are recognized equipment grounding conductors; nonmetallic raceways are not. See NEC 250.118.

Wiring Methods & Materials

Rigid PVC conduit requires an expansion fitting where the expected length change due to temperature is at least what value?

  • a.1/8 inch
  • b.1 inch
  • c.1/2 inch
  • d.1/4 inch✓

Expansion fittings are required for PVC conduit where the length change is expected to be 1/4 inch or more. See NEC 352.44.

Wiring Methods & Materials

How many 12 AWG conductors may be installed in a 21.0-cubic-inch box with no clamps, devices or fittings?

  • a.8
  • b.10
  • c.9✓
  • d.11

Each 12 AWG conductor requires 2.25 cubic inches: 21.0 / 2.25 = 9.33, rounded down to 9 conductors. See NEC 314.16(A) and (B).

Wiring Methods & Materials

What is the maximum permitted conductor fill of a metal wireway?

  • a.31 percent
  • b.53 percent
  • c.20 percent✓
  • d.40 percent

The conductors in a metal wireway may not fill more than 20 percent of its interior cross-sectional area. See NEC 376.22(A).

Wiring Methods & Materials

A raceway enters a building underground from an outside source. What is required at the point of entry?

  • a.It must be sealed or plugged to prevent moisture from entering the building✓
  • b.It must be left open for ventilation
  • c.It must be filled completely with concrete
  • d.It must be bonded but is never sealed

Conduits and raceways entering a building underground must be sealed or plugged with an identified compound to stop moisture and gases from entering. See NEC 300.5(G).

Wiring Methods & Materials

Type NM cable entering a single-gang nonmetallic box that has no cable clamps must be secured within what distance of the box?

  • a.24 inches
  • b.8 inches✓
  • c.3 feet
  • d.4 and 1/2 feet

Where a single-gang nonmetallic box without internal clamps is used, the NM cable must be secured within 8 inches of the box. See NEC 314.17(C) Exception and 334.30(A).

Wiring Methods & Materials

May a raceway be used as a means of support for another raceway or box?

  • a.Yes, in all cases
  • b.Yes, for spans under 6 feet
  • c.Only where the raceway is nonmetallic
  • d.No, except where the raceway is identified for that purpose or specifically permitted✓

Raceways may not be used to support other raceways, cables or nonelectrical equipment unless identified for the purpose or specifically permitted. See NEC 300.11(C).

Wiring Methods & Materials

A junction box contains four 12 AWG and three 10 AWG conductors with no devices, clamps or fittings. What minimum box volume is required?

  • a.16.5 cubic inches✓
  • b.17.5 cubic inches
  • c.14.0 cubic inches
  • d.15.75 cubic inches

Each conductor is counted at the allowance for its own size: four 12 AWG at 2.25 = 9.0, and three 10 AWG at 2.50 = 7.5, for 16.5 cubic inches. See NEC 314.16(B)(1).

Wiring Methods & Materials

What is the minimum trade size of EMT required for six 10 AWG THHN conductors?

  • a.One inch
  • b.Three-quarter inch✓
  • c.One-half inch
  • d.One and one-quarter inch

Annex C, Table C1 shows one-half-inch EMT holds five 10 AWG THHN and three-quarter-inch EMT holds ten, so three-quarter inch is the minimum for six. See NEC Annex C, Table C1.

Wiring Methods & Materials

A metal outlet box is supplied by a wiring method that includes an equipment grounding conductor. How must the box be treated?

  • a.It must be left isolated from ground
  • b.It must be connected to the grounded neutral bar
  • c.It must be connected to the equipment grounding conductor✓
  • d.It need be bonded only in a wet location

A metal box must be connected to an equipment grounding conductor so it is bonded and any fault will clear. See NEC 250.148 and 314.4.

Wiring Methods & Materials

An insulated bushing or fitting to protect conductors from abrasion is required where conductors of what size or larger enter a raceway or enclosure?

  • a.1 AWG
  • b.4 AWG✓
  • c.8 AWG
  • d.6 AWG

Where ungrounded conductors of 4 AWG or larger enter a raceway in a cabinet, box or enclosure, a fitting providing a smoothly rounded insulating surface, such as an insulating bushing, is required. See NEC 300.4(G).

Wiring Methods & Materials

In box-fill calculations, how is a device yoke or strap counted?

  • a.As two conductor volume allowances, based on the largest conductor connected to the device✓
  • b.It is not counted at all
  • c.As one conductor volume allowance
  • d.As two allowances, based on the smallest conductor

Each yoke or strap containing a device or utilization equipment is counted as two conductor volume allowances based on the largest conductor connected to it. See NEC 314.16(B)(4).

这门考试有多难?

熟练/普通电工认证由各州主办、以 NEC 为依据,因此格式因州而异。例如加州的普通电工考试为 100 题,4.5 小时,70% 及格,各项费用合计约 175 美元。电工年薪中位数约 62,350 美元(BLS,2024 年 5 月)。

推荐学习时间
多数人 60-120 小时——NEC 查规范、负载计算与导线/导管选型内容偏重。
首次通过率
51.22% 首次应考(n = 4,150);39.75% 重考(n = 4,150) —— California DIR Electrician Certification Unit,2023。这是加州 General Electrician 考试,也是少数真正公布首考/重考分列数据的技工类考试之一 —— n 为两类考生合计的年度考试次数。执照按州发放,因此这只是一个州的数字:德州 TDLR 公布其 Journeyman 考试 FY 2025 为 27.52%(n = 5,050),但未说明统计的是哪些考次。来源: California DIR/DLSE Electrician Certification Unit — California Electrical Examinations Statistical Overview 2023 (PDF) · Texas TDLR — Electrician Exam Statistics, Fiscal Year 2025
重点学习方向
安装(Installation)在加州考试中占比最大,达 66%——依 NEC 的布线方式、接线盒、导线、服务与设备。

费用与薪资为近似值,会随时间变动。上方的通过率引自旁边链接的来源,并限于该来源覆盖的期间——凡是我们尚未核实来源的,都会直接说明并且不给数字。

反馈