Texas Air Conditioning and Refrigeration Contractor Exam Practice Test
Sample practice questions
A few real questions from this free bank, with full explanations. Use the practice tool above for the whole set.
- 1. Texas Laws and Rules
A contractor holds a Class B license with the environmental air conditioning endorsement. Under Occupations Code §1302.253, which single cooling unit is the largest this contractor may install?
- a.A unit of 50 tons cooling capacity
- b.A unit of 15 tons cooling capacity
- c.A unit of 25 tons cooling capacity
- d.A unit of any cooling capacity
Answer: c
Explanation: §1302.253 limits a Class B license to cooling systems of 25 tons or less and heating systems of 1.5 million Btu/h or less. Fifteen tons is allowed but is not the ceiling, 50 tons is beyond it, and work on a unit of any size is what a Class A license allows.
Source: Tex. Occ. Code §1302.253
- 2. Texas Laws and Rules
Which person is exempt from the licensing law under Occupations Code Chapter 1302 and 16 TAC §75.30?
- a.An owner working on the system in the home the owner solely owns and lives in
- b.A licensed plumber replacing a furnace as part of a water heater job
- c.A friend helping the homeowner install a split system without pay
- d.A landlord replacing the condensing unit at a rental house the landlord owns
Answer: a
Explanation: The homeowner exemption covers only a person working in a building owned solely by that person as the person's home, and §75.30 says it does not extend to others who assist. Plumbers are not exempt under §1302.063, and a rental house is not the owner's home.
Source: Tex. Occ. Code §1302.053, §1302.063; 16 TAC §75.30(a)(2)
- 3. Air Distribution
A filter's MERV rating describes its:
- a.Resistance to airflow when it is clean
- b.Ability to capture particles of stated sizes
- c.Expected service life in a normal home
- d.Maximum allowed face velocity in service
Answer: b
Explanation: MERV (minimum efficiency reporting value) rates how well a filter captures particles in set size ranges; a higher number captures smaller particles. Pressure drop, face velocity limits and service life are separate data from the manufacturer.
- 4. Basic Refrigeration Components
A blended refrigerant with a noticeable temperature glide should be charged into a system:
- a.As a liquid or a vapor, since the blend does not separate
- b.As a vapor, so the blend's composition does not change
- c.As a vapor, so the compressor is not slugged at start-up
- d.As a liquid, so the blend's composition does not change
Answer: d
Explanation: Zeotropic blends fractionate: vapor leaving the cylinder is richer in the more volatile components. Removing liquid keeps the composition correct. Liquid is throttled into the suction side to protect the compressor.
- 5. Controls
A flame rectification sensor proves burner flame by:
- a.Passing a small DC current through the flame to ground
- b.Opening a bimetal contact when its tip is heated
- c.Generating a millivolt signal when its tip is heated
- d.Measuring ultraviolet light given off by the flame
Answer: a
Explanation: The control applies AC to the flame rod, and the flame conducts and rectifies it into a microamp DC signal to the grounded burner. A thermocouple generates millivolts, which is a different and older method.
- 6. Equipment Requirements and Design
Which ACCA manual is used to calculate the heating and cooling loads of a residence?
- a.Manual D
- b.Manual S
- c.Manual T
- d.Manual J
Answer: d
Explanation: Manual J is residential load calculation, Manual S is equipment selection, Manual D is duct design, and Manual T covers air distribution outlets. PSI allows Manuals J, S and D at the Environmental Air exams.
- 7. HVAC and HVACR Systems
A suction line that rises vertically from an evaporator below the compressor needs an oil trap at the bottom of the riser to:
- a.Keep liquid refrigerant from reaching the evaporator
- b.Stop vibration from travelling along the suction line
- c.Help carry oil up the riser back to the compressor
- d.Hold a reserve of refrigerant for periods of high load
Answer: c
Explanation: Oil collects at the base of a vertical suction riser; a trap lets vapor velocity pick the oil up and carry it upward. Without proper velocity and trapping, oil stays in the low side and the compressor runs short.
- 8. Piping
An undersized suction line causes:
- a.High suction pressure at the compressor
- b.Liquid floodback to the compressor
- c.Excess pressure drop and a loss of capacity
- d.Low vapor velocity and poor oil return to the compressor
Answer: c
Explanation: A suction line that is too small has a high pressure drop, which lowers pressure at the compressor, raises the compression ratio and cuts capacity. Poor oil return is the problem with an oversized line, where velocity is too low.
- 9. Ventilation
Doors of a refrigeration machinery room are required to be:
- a.Removable, with an inside key lock
- b.Sliding, with a fusible-link closer
- c.Louvered, held open during operation, and opening inward
- d.Tight-fitting, self-closing, and opening outward
Answer: d
Explanation: Machinery room doors are tight-fitting and self-closing so leaked refrigerant stays in the room, and they swing outward for escape. Openings that would let refrigerant pass to other parts of the building are not allowed.
Source: International Mechanical Code, refrigeration machinery room requirements
- 10. Service
Which leak detection method pinpoints a refrigerant leak without adding anything to the system?
- a.A compressor amperage reading
- b.A standing vacuum test on the system
- c.An electronic leak detector at the joints
- d.A liquid line sight glass inspection for bubbles
Answer: c
Explanation: An electronic detector senses refrigerant escaping at a specific point. A standing vacuum test can show that a leak exists but not where, and vacuum can pull joints closed that leak under pressure.