In steel erection, at what height are workers generally required to be protected from fall hazards?
Giải thích
The steel erection standard sets the general fall protection height at 15 feet, and carves two narrower rules inside it. Connectors must be protected at heights over two storeys or 30 feet, whichever is less, and between 15 and 30 feet may choose between conventional fall protection and a controlled decking zone. Work within a controlled decking zone is exempt from conventional protection where the zone's boundaries, access limits and training are met. That is what makes 30 feet the most attractive wrong answer: it is a genuine number in the same standard, attached to connectors rather than to the general rule. Six feet is the general construction trigger and 10 feet is the supported scaffold trigger.
Trích dẫn luật: 29 CFR 1926.760(a)(1), (b), (c); 1926.501(b)(1); 1926.451(g)(1)Luyện miễn phí toàn bộ 1632 câu hỏi — không cần đăng ký.
Own the complete CSLB Law & Business guide — PDF + EPUB, $24.99 →
Câu hỏi liên quan cùng chủ đề
- Good housekeeping on a construction site — keeping walkways clear of debris, scrap, and combustibles — primarily reduces the risk of:
- Danger, caution, and safety instruction signs on a jobsite are used to:
- Workers on a leading edge 6 feet or more above a lower level must be protected by:
- On a scaffold, in addition to fall protection, what protects workers BELOW from falling objects such as tools?
- A safety net system used for fall protection must be installed as close as practicable under the work surface, but never more than how far below?
- When working from an aerial lift (boom-type elevating work platform), workers must:
Cập nhật gần nhất: · quy trình kiểm tra