California Alarm Company Operator Qualified Manager Exam — All Questions

200 questions

Employer Obligations

A nonexempt installer works 10 hours in one day. The hours over eight are paid at:

  • a.Triple the regular rate
  • b.Half the regular rate
  • c.The regular rate
  • d.Time and one-half✓

California requires overtime at one and one-half times for hours over eight in a day, and double time beyond twelve.

Employer Obligations

A licensee pays installers as independent contractors though it controls their schedules, tools and methods. The main risk is:

  • a.An increase in equipment prices
  • b.A shorter license term
  • c.Misclassification penalties✓
  • d.Loss of the customers' warranties

California's ABC test (Labor Code §2775) presumes employee status; workers under the company's control doing its usual work are employees.

Employer Obligations

An employee complains to the Bureau about the licensee's violations. The licensee may:

  • a.Cut the employee's pay
  • b.Demote the employee
  • c.Fire the employee immediately
  • d.Not retaliate for it✓

Labor Code §1102.5 protects employees who report violations of law to a government agency.

Employer Obligations

Training records for alarm agents must be:

  • a.Sent to each customer
  • b.Kept for Bureau inspection✓
  • c.Kept only by the employee
  • d.Destroyed after each class

§7599.37 requires training records to be maintained, with a $500 fine for failure.

Employer Obligations

A licensee learns an alarm agent's registration has expired. The agent:

  • a.May work on residential jobs only
  • b.May work under another agent's card
  • c.May continue working for one year
  • d.May not work as an alarm agent✓

Registration must be current to perform alarm agent duties; working on another's card is a violation.

Employer Obligations

An alarm agent who is fired within three working days of hire:

  • a.Must be reported to the police
  • b.Must return a firearms permit
  • c.Needs no registration application✓
  • d.Must still be fingerprinted

§7598.4 excuses the application when employment ends within three working days.

Employer Obligations

A licensee who carries or allows a replica firearm on duty commits a violation carrying a fine of:

  • a.$50,000 for the first violation
  • b.$5,000 for the first violation
  • c.$5 for the first violation
  • d.$100 for the first violation✓

§7597.2 sets fines of $100 for a first violation and $250 for later ones.

Employer Obligations

Outdoor installers working in high heat must be given:

  • a.Sunscreen only
  • b.A bonus in place of water or shade
  • c.Water, shade and rest breaks✓
  • d.Nothing, if they are paid by the job

Title 8 §3395 requires water, shade, rest and training for outdoor work.

Employer Obligations

When an alarm agent's home address changes, the Bureau must be notified. Failure carries a fine of:

  • a.$25,000
  • b.$5,000
  • c.$10,000
  • d.$50✓

§7599.59 sets a $50 fine for failing to report an address change.

Employer Obligations

A licensee's weapons record under §7599.41 lists:

  • a.Deadly weapons the business holds✓
  • b.The local police department's weapons
  • c.The customers who own firearms
  • d.The manufacturer's price list

The Act requires a current record of the weapons the licensee holds for the business.

Project Consultation & Plan

The first step in designing an alarm system for a customer is to:

  • a.Order the most expensive control panel
  • b.Schedule the installation crew
  • c.Survey the premises and its risks✓
  • d.Print the monitoring certificate

A site survey identifies assets, entry points, occupants' habits and environmental conditions that drive the design.

Project Consultation & Plan

Perimeter protection is best described as detection at:

  • a.The monitoring center
  • b.The alarm control panel only
  • c.Doors, windows and other openings✓
  • d.The center of each room

Perimeter devices such as contacts and glass break sensors detect entry at openings; interior devices detect movement inside.

Project Consultation & Plan

A customer has large dogs that roam the house while the system is armed. The designer should:

  • a.Favor perimeter devices or pet-tolerant detectors✓
  • b.Install standard motion detectors aimed at the floor
  • c.Leave the system unarmed when the dogs are home
  • d.Disable the siren to avoid upsetting the dogs

Animals are a leading cause of motion detector false alarms, so the design relies on perimeter devices or detectors rated and placed for pets.

Project Consultation & Plan

A written agreement for an alarm system must be given to the customer:

  • a.Signed, before any work begins✓
  • b.Only if the customer asks for it
  • c.After the first monitoring payment
  • d.Within 90 days after installation

§7599.54 requires a signed copy to be delivered before work starts.

Project Consultation & Plan

Under §7599.54, the written agreement must include the:

  • a.Wholesale cost of each component
  • b.Names of the licensee's other customers
  • c.Licensee's name and license number✓
  • d.Qualified manager's Social Security number

The section lists the licensee's identifying information and license number, along with the soliciting agent's name and registration number.

Project Consultation & Plan

The agreement must state approximate dates for:

  • a.The manufacturer's product recall
  • b.The licensee's next renewal
  • c.The customer's next insurance audit
  • d.Starting and finishing the work✓

§7599.54 requires approximate start and substantial completion dates.

Project Consultation & Plan

The description of the system in the agreement must cover:

  • a.The installer's training history
  • b.Only the color of the siren
  • c.Only the brand of the keypad
  • d.Major components and services✓

§7599.54 requires a description of the system including major components and post-installation services.

Project Consultation & Plan

A residential agreement that renews automatically for more than one month must:

  • a.Hide the renewal in the general terms
  • b.Be approved by the local police
  • c.Renew for no less than five years
  • d.Disclose the renewal separately✓

For agreements entered on or after January 1, 2017, §7599.54 requires a clear, separate automatic renewal disclosure that the customer signs or initials.

Project Consultation & Plan

The agreement must tell the customer that the alarm company:

  • a.Guarantees no burglary will occur
  • b.Will teach the purchaser its use✓
  • c.Is not regulated by any agency
  • d.May enter the premises at any time

§7599.54 requires a statement that the company shall instruct the purchaser in proper use upon completion. It also requires a disclosure identifying the Bureau.

Project Consultation & Plan

An alarm company's agreement should never state that the system:

  • a.Will be serviced on request
  • b.Will be tested after installation
  • c.Guarantees the premises against loss✓
  • d.Includes a backup battery

An alarm reduces risk but cannot guarantee against loss; such a promise is misleading and creates liability.

Project Consultation & Plan

During installation the customer asks for added sensors not in the agreement. The installer should:

  • a.Get a written change order first✓
  • b.Add them and bill whatever seems fair
  • c.Refuse all changes after signing
  • d.Remove other sensors to offset the cost

§7599.50 penalizes departing from plans or specifications without consent; a signed change order documents consent and price.

Project Consultation & Plan

May an alarm agreement be signed electronically?

  • a.Only for commercial customers
  • b.No, only ink signatures are valid
  • c.Yes, the Act permits electronic agreements✓
  • d.Only with a notary present

§7599.56 allows agreements to be made and delivered electronically.

Project Consultation & Plan

Before running cable in a commercial building, the planner should confirm:

  • a.The make of the customer's vehicles
  • b.Local permit and code requirements✓
  • c.The customer's credit card rewards
  • d.The names of neighboring tenants

§7599.51 penalizes disregarding building, safety and labor laws; permits and code requirements vary by jurisdiction.

Project Consultation & Plan

Many cities require the alarm user to hold:

  • a.A local alarm permit✓
  • b.A locksmith license
  • c.A firearms permit
  • d.A contractor's license

§7592.8 recognizes local alarm user permits and false alarm ordinances. The other licenses are for trades, not users.

Project Consultation & Plan

In choosing detection for a space with skylights, heaters and moving banners, the designer should expect:

  • a.False alarms from motion detectors✓
  • b.Better performance from every detector
  • c.No effect on any detector type
  • d.That contacts will stop working

Heat sources, sunlight and moving objects can trigger passive infrared or microwave detectors, so device type and placement are chosen for the environment.

Project Consultation & Plan

A holdup or panic button is designed to be:

  • a.Placed where customers can press it
  • b.Activated whenever the door opens
  • c.Wired to the door chime
  • d.Hard to trip by accident✓

Holdup devices send a high-priority signal and are placed and designed to prevent accidental use.

Project Consultation & Plan

When estimating a job, standby battery size is based on:

  • a.The number of keypads sold last year
  • b.The length of the customer's driveway
  • c.Current draw and standby time✓
  • d.The brand of the siren only

Battery capacity in ampere-hours comes from total standby and alarm current multiplied by the required hours, with a margin.

Project Consultation & Plan

A licensed alarm company may install an electronic access control lock without a locksmith license when:

  • a.An alarm control device controls the lock✓
  • b.The lock costs under $100
  • c.The customer is a relative of the installer
  • d.The work is done at night

§7590.2 exempts operators from locksmith licensing for electronic locks and access control devices controlled by an alarm control device when combined with alarm work.

Project Consultation & Plan

A proposal compares a local-only alarm with a monitored system. The key difference is that a monitored system:

  • a.Needs no control panel
  • b.Sends signals to a monitoring center✓
  • c.Cannot be armed by the user
  • d.Never sounds a siren on the premises

A local alarm only sounds on site; a monitored system also transmits signals for dispatch.

Project Consultation & Plan

A customer wants cameras that record audio in an employee break room. The planner should:

  • a.Install hidden microphones as requested
  • b.Warn that such recording requires consent✓
  • c.Promise that all audio recording is legal
  • d.Add microphones in the restrooms too

Penal Code §632 requires all-party consent to record confidential communications; a company should not install a system for unlawful eavesdropping.

Alarm Installation

A magnetic door contact consists of:

  • a.A reed switch and a magnet✓
  • b.A lens and a heat-sensing element
  • c.A transmitter and a reflector
  • d.A microphone and an amplifier

The magnet holds a reed switch in one state while the door is closed; opening the door changes the circuit. Lenses, microphones and reflectors belong to other detectors.

Alarm Installation

A normally closed alarm loop goes into alarm when:

  • a.The circuit opens✓
  • b.The circuit stays closed
  • c.The siren is silenced
  • d.The keypad is lit

In a closed loop, current flows through closed contacts; opening a contact or cutting the wire breaks the circuit and trips the zone.

Alarm Installation

The purpose of an end-of-line resistor is to let the panel:

  • a.Charge the standby battery faster
  • b.Raise the voltage on the loop
  • c.Supervise the wiring for faults✓
  • d.Make the siren louder

With a known resistance at the end of the loop, the panel can tell normal, open and shorted conditions apart.

Alarm Installation

An end-of-line resistor should be installed:

  • a.Inside the control panel cabinet
  • b.At the siren
  • c.At the last device on the loop✓
  • d.At the transformer terminals

A resistor at the panel supervises none of the field wiring; at the last device it supervises the whole run.

Alarm Installation

A passive infrared (PIR) detector senses:

  • a.Reflected microwave energy from any object
  • b.Sound at the frequency of breaking glass
  • c.Changes in received infrared energy✓
  • d.The opening of a magnetic field

A PIR is passive: it emits nothing and reacts to changes in heat energy across its detection pattern.

Alarm Installation

A PIR detector is most sensitive to movement that is:

  • a.Outside the building
  • b.Across its field of view✓
  • c.Directly toward it
  • d.Behind a solid wall

Crossing the detection zones produces the greatest change in received energy, so the detector is placed where an intruder would walk across the pattern.

Alarm Installation

A PIR detector should not be aimed at:

  • a.A heater or window✓
  • b.An interior hallway
  • c.A carpeted floor
  • d.A closed interior door

Rapid changes in infrared energy from heaters or sunlight can cause false alarms.

Alarm Installation

A microwave motion detector differs from a PIR because it:

  • a.Emits its own energy✓
  • b.Has no electronic parts
  • c.Works only outdoors
  • d.Detects only temperature

Microwave detectors are active devices whose energy can penetrate non-metallic materials, so range must be adjusted to the protected room.

Alarm Installation

A dual-technology detector reduces false alarms by requiring:

  • a.Both technologies✓
  • b.Two keypads
  • c.Two control panels
  • d.Two sirens

Combining PIR and microwave so that both must detect makes an alarm from a single environmental cause less likely.

Alarm Installation

An acoustic glass break detector should be:

  • a.Mounted inside a closet away from the glass
  • b.Mounted behind heavy drapes
  • c.Left untested after mounting
  • d.In range and line of sight of the glass✓

Range, obstructions and room acoustics affect performance, so the detector is placed per the manufacturer's instructions and checked with a tester.

Alarm Installation

A shock or vibration sensor mounted on glass or a wall detects:

  • a.Body heat
  • b.Open doors
  • c.Impact✓
  • d.Smoke

Shock sensors respond to vibration from an attack on the surface.

Alarm Installation

A photoelectric beam detector alarms when:

  • a.Its beam is interrupted✓
  • b.The battery is full
  • c.The telephone rings
  • d.The room temperature changes

Beam detectors protect a line; an intruder breaking the beam trips the zone.

Alarm Installation

A zone that is "supervised" means the panel:

  • a.Reports the zone only once a year
  • b.Powers the zone from the siren
  • c.Ignores the zone when armed
  • d.Monitors the zone for trouble✓

Supervision detects faults such as open wiring, tamper or a missing wireless sensor.

Alarm Installation

A tamper switch on a control cabinet or device is intended to:

  • a.Reset the system's clock
  • b.Dim the keypad at night
  • c.Report an opened cover✓
  • d.Silence the siren

Tamper protection reports interference with equipment.

Alarm Installation

The plug-in transformer for a control panel should be connected to:

  • a.An unswitched, secured receptacle✓
  • b.A receptacle shared with a space heater
  • c.An extension cord run under a rug
  • d.A receptacle controlled by a wall switch

A switched outlet can cut power without anyone noticing until the battery is drained; securing the transformer prevents accidental unplugging.

Alarm Installation

The purpose of the standby battery in a control panel is to:

  • a.Supervise the telephone line
  • b.Increase the transformer's voltage
  • c.Replace the end-of-line resistors
  • d.Run the system when power fails✓

The battery supplies the system when utility power fails.

Alarm Installation

A system draws 0.5 ampere in standby and must run for 4 hours on battery. The minimum capacity, before any safety margin, is:

  • a.2 ampere-hours✓
  • b.8 ampere-hours
  • c.4.5 ampere-hours
  • d.0.125 ampere-hours

Capacity equals current multiplied by time: 0.5 A × 4 h = 2 Ah. A margin is then added.

Alarm Installation

By Ohm's law, a 12-volt circuit with a 24-ohm load draws:

  • a.2 amperes
  • b.288 amperes
  • c.36 amperes
  • d.0.5 ampere✓

Current equals voltage divided by resistance: 12 ÷ 24 = 0.5 A.

Alarm Installation

Voltage drop on a long wire run to a device is reduced by:

  • a.Using a larger conductor✓
  • b.Adding more devices to the run
  • c.Using a smaller conductor
  • d.Coiling the excess wire

Larger conductors have lower resistance. Smaller wire and added load increase the drop.

Alarm Installation

Devices on a power circuit that must each receive full supply voltage are wired in:

  • a.Parallel✓
  • b.A single open loop
  • c.Series
  • d.Reverse polarity

In parallel each device sees the supply voltage; in series the voltage divides among devices.