Normally closed contacts on a single zone loop are wired in:
- a.Series✓
- b.A power circuit
- c.Parallel
- d.Reverse polarity
In series, opening any one contact opens the loop. Normally open devices are wired in parallel.
Most burglar alarm field wiring is classified under the National Electrical Code as:
- a.Feeders
- b.Service entrance conductors
- c.Power-limited circuits✓
- d.Branch circuits for appliances
Alarm signaling circuits are power-limited circuits covered by the Code's rules for Class 2 and similar wiring.
Low-voltage alarm cable should not be run:
- a.Inside a listed cable jacket
- b.With power conductors✓
- c.Along a wall cavity
- d.Through an attic
The Code requires separation of power-limited cables from light and power conductors to prevent hazardous voltages on the alarm wiring.
Cable installed in an air-handling (plenum) ceiling space must be:
- a.Plenum-rated✓
- b.Any type if short
- c.Unjacketed
- d.Lamp cord
Plenum-rated cable has low smoke and flame spread characteristics required for air-handling spaces.
When a cable passes through a fire-rated wall, the opening must be:
- a.Enlarged for air flow
- b.Left open for future cables
- c.Firestopped as approved✓
- d.Packed with newspaper
The Code requires penetrations of fire-rated assemblies to be firestopped to maintain the rating.
Alarm cables above a suspended ceiling should be supported by:
- a.Their own structural supports✓
- b.Electrical conduit
- c.Sprinkler pipes
- d.The ceiling grid wires and tiles
The Code does not allow cables to lie on ceiling tiles or be attached to pipes or conduit not intended for that purpose.
Stapling alarm cable so tightly that the insulation is crushed can cause:
- a.Intermittent faults✓
- b.Longer battery life
- c.Faster signal speed
- d.A louder siren
Damaged insulation leads to shorts, grounds and intermittent troubles, a common cause of false alarms.
Splices in alarm wiring should be:
- a.Avoided by leaving wires loose
- b.Tight, secure and insulated✓
- c.Made only with masking tape
- d.Twisted and left bare
Poor connections corrode and loosen, producing troubles and false alarms.
A wireless sensor's "supervisory" or check-in signal lets the panel detect:
- a.The weather outside
- b.A failed transmitter✓
- c.The siren's volume
- d.The customer's passcode
Supervised wireless devices report periodically; a missed check-in creates a trouble condition.
Before final placement of a wireless sensor, the installer should:
- a.Remove its battery
- b.Paint the transmitter
- c.Mount it on a metal door without testing
- d.Test signal strength at that location✓
Radio signals are affected by distance and building materials, so signal strength is verified before mounting.
An entry delay allows the user to:
- a.Bypass every zone
- b.Leave the premises after arming
- c.Change the master code
- d.Enter and disarm before an alarm✓
Entry delay starts when the entry door opens. Exit delay governs leaving.
An exit delay that is too short most often results in:
- a.False alarms on exit✓
- b.A weaker radio signal
- c.Longer entry time
- d.Lower battery voltage
Users who cannot leave and close the door in time trip the system, a common user-caused false alarm.
An interior "follower" zone is one that:
- a.Sounds the chime only
- b.Is always instant
- c.Delayed after entry✓
- d.Is always bypassed
A follower zone along the entry path follows the entry delay; if tripped first it alarms at once.
A 24-hour zone is active:
- a.Only when the system is armed away
- b.Only during a power failure
- c.Only during business hours
- d.Whether the system is armed or disarmed✓
Panic, holdup and tamper zones are typically 24-hour zones.
The exterior siren or bell should be mounted:
- a.At ground level beside the door
- b.Inside the control cabinet
- c.High and tamper protected✓
- d.On a fence post at the street
A sounder within easy reach can be disabled; tamper protection and height reduce that risk.
Which document governs how a specific device is to be installed?
- a.The customer's color scheme
- b.The installer's personal preference
- c.A competitor's brochure
- d.The manufacturer's instructions✓
Listed equipment must be installed according to its instructions and listing.
UL 681 addresses:
- a.Burglar alarm installation✓
- b.Residential plumbing fixtures
- c.Automobile emissions
- d.Elevator maintenance
UL 681 is the standard for installing and classifying commercial burglar and holdup alarm systems.
UL 1641 addresses:
- a.Commercial kitchen hoods
- b.Residential burglar alarms✓
- c.Highway signs
- d.Gas appliance venting
UL 1641 covers residential burglar alarm system installation and classification.
After installation, the installer should:
- a.Ask the customer to test alone later
- b.Test only the keypad
- c.Test every zone and its signals✓
- d.Leave before powering up
A complete functional test, with the monitoring center on test, verifies each device and the communication path.
Before testing signals with a monitored system, the installer should:
- a.Disconnect the battery
- b.Remove the siren
- c.Call the police non-emergency line
- d.Place the account on test✓
Placing the account on test prevents a dispatch on test signals.
§7599.58 prohibits a licensee from:
- a.Testing a system
- b.Offering a warranty
- c.Training the customer
- d.Knowingly defective work✓
The section bars knowingly defective installations and requires warranty service and notice to the owner of defects.
The fine for a first violation of the defective installation rule in §7599.58 is:
- a.$2,500
- b.$1,000✓
- c.$5,000
- d.$100
§7599.58 sets $1,000 for a first violation and $2,500 to $5,000 for later ones.
A licensee who walks away from an unfinished installation without legal excuse:
- a.Is within its rights
- b.May keep the equipment
- c.Violates the Act✓
- d.Owes only a refund
§7599.49 penalizes abandoning a project, with fines of $100 and $500.
An installer needs to enter a locked suite to finish wiring and no one is present. The installer should:
- a.Wait for consent✓
- b.Force the door
- c.Enter through a window
- d.Ask a neighbor for a key
§7599.45 forbids entering premises without consent.
Grounding the control panel as the manufacturer directs helps protect against:
- a.Low signal strength
- b.Forgotten passcodes
- c.Lightning and surges✓
- d.Dead keypad lights
A proper ground gives surge energy a path away from sensitive electronics.
A zone trips at random on a windy day. A likely installation cause is:
- a.A loose door✓
- b.A new keypad
- c.A full battery
- d.A strong signal
Doors that rattle in the frame can separate a contact and magnet beyond the operating gap.
The keypad should be located:
- a.In the attic
- b.In a window facing the street
- c.Outside the front door
- d.Inside, near the entry door✓
Users must reach it within the entry delay, but codes should not be visible to someone watching from outside.
A cellular communicator is often installed because it:
- a.Requires no antenna
- b.Needs no phone line✓
- c.Cannot be supervised
- d.Needs no power
A wireless path avoids the vulnerability of an exposed telephone line.
When the installation is complete, the Act requires the company to:
- a.Train the purchaser in its use✓
- b.Leave written codes on the keypad
- c.Disable user codes
- d.Keep the manual
§7599.54 requires the agreement to state this duty, and user training is the most effective false alarm prevention step.
An installer notices existing wiring that violates the electrical code. The installer should:
- a.Tell the customer✓
- b.Hide it behind a panel
- c.Connect to it anyway
- d.Say nothing
§7599.51 penalizes disregarding building and safety laws, and §7599.58 requires notifying the owner of defects.
The most common cause of false alarms is:
- a.Earthquakes
- b.Power surges
- c.Lightning
- d.User error✓
Industry and police data consistently attribute most false alarms to user mistakes such as wrong codes and unsecured doors.
The most effective false alarm prevention step at turnover is:
- a.Raising the siren volume
- b.Removing the keypad
- c.Hands-on user training✓
- d.Shortening every delay
Users who practice arming, disarming and cancelling make fewer errors.
A customer reports frequent false alarms from one motion detector. The technician should first:
- a.Inspect the detector's location✓
- b.Replace the control panel
- c.Tell the customer to stop arming
- d.Remove the zone permanently
Heat sources, pets, moving objects and insects are common causes that inspection reveals.
A "swinger shutdown" feature:
- a.Stops repeat alarms✓
- b.Locks the keypad
- c.Opens the garage door
- d.Doubles the exit delay
After a set number of trips the zone is shut down until the system is disarmed, limiting repeated dispatches.
An "abort window" is a short period during which:
- a.The battery charges
- b.Disarming stops the signal✓
- c.Codes can be changed
- d.The siren cannot sound
A brief transmission delay lets a user who trips the system enter a code to abort the signal.
Cross-zoning reduces false alarms by requiring:
- a.Two batteries in each panel
- b.Two zones to trip together✓
- c.Two keypads at each door
- d.Two sirens outdoors
A single faulty sensor will not cause a dispatch when a second zone must confirm.
Enhanced call verification means the monitoring center:
- a.Calls two numbers first✓
- b.Calls the police first
- c.Calls only the installer
- d.Never calls the premises
Calling the premises and then a second number, such as a cell phone, resolves many alarms without dispatch.
The ANSI/SIA CP-01 standard concerns:
- a.Electrical service sizing
- b.False alarm reduction✓
- c.Elevator recall
- d.Fire sprinkler spacing
CP-01 sets features and default settings, such as exit delays and abort windows, aimed at reducing user-caused false alarms.
An audible exit warning with a faster tone near the end helps by:
- a.Testing the telephone line
- b.Resetting the clock
- c.Charging the battery
- d.Warning that time is short✓
Progress annunciation tells the user to leave or disarm before the system arms.
A user arms the system and then re-enters within the exit time. A panel with "exit time restart" will:
- a.Disarm permanently
- b.Restart the exit delay✓
- c.Bypass all zones
- d.Send an immediate alarm
Restarting the delay gives the user time to leave again without causing an alarm.
A low battery trouble signal should be handled by:
- a.Disconnecting the trouble sounder
- b.Testing and replacing the battery✓
- c.Unplugging the transformer
- d.Ignoring it until an alarm occurs
A weak battery can cause erratic operation and failure during an outage.
Routine maintenance of an alarm system includes:
- a.Repainting the sensors
- b.Changing the account number
- c.Testing devices and battery✓
- d.Rewiring every year
Periodic testing confirms the system still detects and communicates.
A zone shows a "trouble" condition on a supervised loop with all doors closed. A likely cause is:
- a.A correct passcode
- b.A full battery
- c.A wiring fault✓
- d.A quiet siren
With an end-of-line resistor, a reading outside the normal range indicates a wiring fault.
The instrument used to measure loop resistance and voltage is a:
- a.Torque wrench
- b.Stud finder
- c.Tape measure
- d.Multimeter✓
A multimeter measures voltage, resistance and current for troubleshooting.
A normal reading on a zone with a 2,000-ohm end-of-line resistor is about:
- a.2,000 ohms✓
- b.Infinite ohms
- c.12 volts
- d.0 ohms
The meter should read the resistor's value plus a small wire resistance; zero indicates a short and infinity an open.
To find an intermittent open on a long loop, a technician can:
- a.Test each half of the loop✓
- b.Replace every device at once
- c.Raise the supply voltage
- d.Remove the resistor
Halving the circuit narrows the fault location quickly.
A service technician must leave the system:
- a.Powered down
- b.Operational and tested✓
- c.Bypassed without telling anyone
- d.On test indefinitely
The customer relies on the system; unreported bypasses leave the premises unprotected.
A zone is bypassed at the customer's request. The technician should:
- a.Hide it from the customer
- b.Document and explain it✓
- c.Remove the sensor
- d.Bypass all other zones too
The customer must understand the reduced protection, and records protect both parties.
Under §7599.58 a licensee who discovers a defect in a system it installed must:
- a.Conceal it
- b.Bill for a new system
- c.Cancel the contract
- d.Notify the owner✓
The section requires notice of defects and warranty service.
A customer remodels and adds a wall that blocks a motion detector. The company should:
- a.Re-evaluate the coverage✓
- b.Leave the detector as is
- c.Increase siren volume
- d.Shorten the entry delay
Changes to the premises alter coverage; periodic review keeps the system effective.