PrepPass team · Verified against TSBPE — Tradesman Plumber-Limited License · How we review
Free · printable · no signup
Texas Tradesman Plumber-Limited Exam Cheat Sheet (2026)
A free, printable Texas Tradesman Plumber-Limited exam cheat sheet: the 64 highest-yield points to know, grouped into 7 sections that follow the exam's content areas.
- Free to read, print and keep — no signup, no email, no paywall.
- 64 of the 64 points carry a citation to the rule they come from.
- The real Texas Tradesman Plumber-Limited exam: 85 questions · 120 minutes · 70% to pass.
- Prints from your browser (Ctrl-P, or Cmd-P on a Mac) — the navigation, buttons and links drop out of the printed copy.
- 199 free Texas Tradesman Plumber-Limited practice questions on the same material, every one explained.
Plumbing License Law and Board Rules
- Scope
- One-family and two-family dwellings only, under an RMP.· Tex. Occ. Code §1301.002(10)
- Experience
- 4,000 hours as a registered plumber's apprentice, or completion of an approved career and technology education course sequence.· Tex. Occ. Code §§1301.354, 1301.3542
- Training
- 24 hours of Board-approved classroom training before the exam.· Tex. Occ. Code §1301.354
- Offering work
- Only an RMP, or a company that has secured one, offers plumbing to the public and pulls permits.· Tex. Occ. Code §1301.351
- Pass mark
- 70 percent on each part.· 22 TAC §363.22
- Retakes
- 30 days after a first failure, 60 after a second, 90 after a third or later.· 22 TAC §363.22
- Continuing education
- 6 hours a year, 3 on health protection, energy conservation and water conservation.· Tex. Occ. Code §1301.404
- Late renewal
- 90 days or less: one and a half times the fee. Two years or more: new license and exam.· Tex. Occ. Code §1301.403
- Address change
- Reported to the Board within 30 days.· 22 TAC §365.8
- Penalty
- Up to $5,000 per violation, each day separate.· Tex. Occ. Code §1301.702
- Homestead
- Work by an owner in the owner's homestead is exempt from licensing.· Tex. Occ. Code §1301.051
- Adopted codes
- UPC and IPC, with the IFGC and IRC; the Board rule lists the 2018 editions.· Tex. Occ. Code §1301.255; 22 TAC §367.2
- Vehicles
- Company name and RMP license number on both sides, letters at least 2 inches high.· 22 TAC §367.10
General Requirements and Fixtures
- Shield plates
- Required where piping is close to the face of framing; see the section for the distance.· IRC §P2603.2.1
- Bedding
- Buried pipe rests on a firm, continuous bed for its full length.· IRC §P2604.1
- Support
- Spacing depends on the pipe material.· IRC Table P2605.1
- DWV test
- Water or air test at rough-in.· IRC §P2503.5
- Water supply test
- At not less than working pressure.· IRC §P2503.7
- Water closet clearances
- Side and front clearances are set by the fixture section.· IRC §P2705.1
- Shower valves
- Pressure-balance or thermostatic valves with a temperature limit.· IRC §P2708.4
- Floor drains
- Outlet at least 2 inches, with a removable strainer.· IRC §P2719.1
Water Heaters
- Pans
- Required where leakage would cause damage; the pan drains to an approved location.· IRC §P2801.6
- Garage installation
- Ignition source raised above the floor.· IRC §P2801.7
- Relief valve
- Temperature and pressure relief required.· IRC §P2804
- Discharge pipe
- Not smaller than the valve outlet, no valves or traps, not threaded at the end.· IRC §P2804.6.1
- Mixing valve
- Required for combination water and space heating appliances at higher temperatures.· IRC §P2803.2
Water Supply and Distribution
- Air gap
- The most reliable protection; measured from the outlet to the flood level rim.· IRC §P2902.3.1
- Hose bibbs
- Protected by a vacuum breaker.· IRC §P2902.4.3
- Access
- Backflow assemblies are accessible.· IRC §P2902.6
- Maximum pressure
- A pressure-reducing valve is required above the code limit.· IRC §P2903.3.1
- Fixture supply sizes
- Minimum sizes by fixture.· IRC Table P2903.6 and §P2903.8
- Trap primers and reverse osmosis
- Covered by their own sections.· IRC §§P2906.9.1, P2909.2
Sanitary Drainage
- Slope
- 1/4 inch per foot for 2-1/2 inches and smaller; 1/8 inch per foot for 3 inches and larger.· IRC §P3005.3
- Fixture units
- A lavatory is 1; a tub, shower or kitchen sink 2; a 1.6-gallon water closet 3; a full bath group 5.· IRC Table P3004.1
- Branch capacity
- 1-1/2 inch: 3 dfu. 2 inch: 6 dfu. 3 inch: 20 dfu.· IRC Table P3005.4.1
- Size
- Drain size is not reduced in the direction of flow.· IRC §P3005.1.6
- Fittings
- Sanitary tees not used horizontal to horizontal.· IRC Table P3005.1
- Prohibited joints
- Cement or mortar joints, saddle fittings, solvent cement between different plastics.· IRC §P3003.2
- Cleanout spacing
- Not more than 100 feet apart; at changes of direction over 45 degrees; near the building drain and sewer junction.· IRC §P3005.2
- Sump pit
- At least 18 inches in diameter and 24 inches deep, with a gastight cover.· IRC §P3007.3.2
- Ejector discharge
- Check valve and full-open valve.· IRC §P3007.1
- Backwater valve
- Required for fixtures below the next upstream manhole cover; accessible.· IRC §P3008
Vents and Traps
- Trap seal
- Not less than 2 inches and not more than 4 inches.· IRC §P3201.2
- Prohibited traps
- S traps, bell traps, drum traps, crown-vented traps.· IRC §P3201.5
- Outlet to trap
- Not more than 24 inches vertically and 30 inches horizontally.· IRC §P3201.6
- Trap sizes
- Lavatory 1-1/4 inch; tub, shower, kitchen sink 1-1/2 inch; washer standpipe 2 inch.· IRC Table P3201.7
- Trap arm length
- 1-1/4 inch: 5 feet. 1-1/2 inch: 6 feet. 2 inch: 8 feet. 3 inch: 12 feet.· IRC Table P3105.1
- Fall
- Not more than one pipe diameter.· IRC §P3105.2
- Crown vent
- No vent within two pipe diameters of the trap weir.· IRC §P3105.3
- Roof terminal
- At least 6 inches above the roof.· IRC §P3103.1.1
- Offsets
- Not below 6 inches above the flood level rim of the highest fixture served.· IRC §P3104.4
- Size
- At least half the drain diameter and never under 1-1/4 inches; one size larger over 40 feet.· IRC §P3113.1
- Wet vent
- Fixtures of up to two bathroom groups on the same floor.· IRC §P3108.1
- Air admittance valves
- Installed after testing, accessible, 4 inches above the drain served, 6 inches above attic insulation.· IRC §P3114
Fuel Gas Piping
- Prohibited locations
- Ducts, clothes chutes, chimneys, dumbwaiters, elevator shafts.· IRC §G2415.3
- Concealed fittings
- No unions or bushings in concealed locations.· IRC §G2415.5
- Burial
- At least 12 inches deep.· IRC §G2415.12
- Plastic pipe
- Outdoors and underground only; yellow insulated copper tracer wire.· IRC §§G2415.17.1, G2415.17.3
- CSST bonding
- Bonding jumper not smaller than 6 AWG copper.· IRC §G2411.2
- Test pressure
- 1-1/2 times working pressure and not less than 3 psig.· IRC §G2417.4.1
- Duration
- Not less than 10 minutes.· IRC §G2417.4.2
- Shutoff valve
- Same room, within 6 feet of the appliance.· IRC §G2420.5.1
- Connector
- Not longer than 6 feet, not concealed.· IRC §G2422.1.2.1
- Sediment trap
- Downstream of the shutoff, close to the appliance inlet.· IRC §G2419.4
Now prove you know them
Reading an outline is not the same as recalling it under exam pressure. Drill the free Texas Tradesman Plumber-Limited questions to find the areas you keep missing, then sit a full timed mock.
Study aid, not a substitute for the official material — always confirm the current rule with TSBPE — Tradesman Plumber-Limited License.