Silica, lead, and asbestos standards all share which common employer requirement?
Explicación
All three standards are built on the same frame: determine the exposure, apply engineering and work-practice controls to bring it down, add respiratory protection where the controls cannot reach the limit alone, train the workers, and provide medical surveillance once the action level or the limit is exceeded - so assessment, controls and training are common ground. The wrong answers are genuine requirements attached to one of the three only. Air clearance sampling (c) is asbestos practice and has no counterpart in the silica standard. Registration with the Division (a) applies to asbestos-related work in California, alongside certification under Business and Professions Code section 7058.5, but not to silica or lead work as such. And owner or neighbour notification (d) comes from environmental and renovation rules, not from these health standards.
Referencia Legal: 8 CCR §1529; §1532.1; 29 CFR 1926.1153; B&P §7058.5Practica las 1632 preguntas gratis — sin registro.
Own the complete CSLB Law & Business guide — PDF + EPUB, $24.99 →
Preguntas relacionadas de este tema
- A warning line system, used in some low-slope roofing work, functions to:
- A 'controlled decking zone' (CDZ) in steel erection is an area where:
- In steel erection, to protect workers below from falling objects, all materials and tools at heights must be:
- OSHA requires the employer to instruct each employee in:
- A contractor with 3 employees insists it is 'too small' to need any safety program. The correct response is:
- On a steep-slope roof, workers 6 feet or more above a lower level must be protected by: