SeguridadPregunta 1346 de 1632

On a steep-slope roof, workers 6 feet or more above a lower level must be protected by:

a.Slide guards fixed along the eave, on any slope
b.A safety monitor alone, on roofs 50 feet or less wide
c.Guardrails with toeboards, nets, or fall arrest
d.A warning line set back six feet from the eave

Explicación

On a steep roof - slope greater than 4 in 12 - at 6 feet or more above a lower level, the federal rule allows conventional fall protection only: a guardrail system with toeboards, a safety net system, or a personal fall arrest system. What the wrong answers have in common is that all three are low-slope measures. Warning lines and safety monitoring systems are permitted on LOW-slope roofs, and a monitoring system alone only on roofs 50 feet or less in width; neither is available on a steep roof at any height. Slide guards are a roofing-trade device with no standing as conventional fall protection. In California roofing runs under section 1730, with residential-type roofing under section 1731, and those orders set their own methods by slope and by covering type.

Referencia Legal: 29 CFR 1926.501(b)(10)-(11); 1926.502(f)-(h); 8 CCR §1730; §1731

Practica las 1632 preguntas gratis — sin registro.

Own the complete CSLB Law & Business guide — PDF + EPUB, $24.99 →

Preguntas relacionadas de este tema

Última revisión: · proceso editorial

Equipo de PrepPass · Verificado con California CSLB Contractor License Law & Business Exam · Cómo revisamos
Revisado por Abraham Chen — Licensed California General Contractor (CSLB License #1101856 — verificar)
Reportar