California Civil Engineer: Seismic Principles — All Questions

78 questions

Seismic Analysis Procedures

A torsional moment of 1,500 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 5 lies 20 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 6,400. What torsional shear does this wall receive?

  • a.4.7 kips
  • b.23.4 kips✓
  • c.46.9 kips
  • d.75.0 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 1,500 x 5 x 20 / 6,400 = 23.4 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (75.0 kips) assumes that single wall resists all of the torsion.

Seismic Analysis Procedures

At one level of a torsionally irregular building in SDC D, the displacements at the two ends of the rigid diaphragm are 1.5 in. and 0.7 in. What accidental torsion amplification factor Ax applies?

  • a.1.00
  • b.1.14
  • c.1.29✓
  • d.1.86

ASCE 7-16 Eq. 12.8-14: Ax = [delta_max/(1.2 delta_avg)]^2 with delta_avg = (1.5 + 0.7)/2 = 1.10 in. Ax = [1.5/(1.2 x 1.10)]^2 = 1.29, bounded between 1.0 and 3.0. Forgetting to square the ratio or dropping the 1.2 are the common errors.

Seismic Analysis Procedures

At one level of a torsionally irregular building in SDC D, the displacements at the two ends of the rigid diaphragm are 2.0 in. and 1.0 in. What accidental torsion amplification factor Ax applies?

  • a.1.23✓
  • b.1.54
  • c.1.78
  • d.3.00

ASCE 7-16 Eq. 12.8-14: Ax = [delta_max/(1.2 delta_avg)]^2 with delta_avg = (2.0 + 1.0)/2 = 1.50 in. Ax = [2.0/(1.2 x 1.50)]^2 = 1.23, bounded between 1.0 and 3.0. Forgetting to square the ratio or dropping the 1.2 are the common errors.

Seismic Analysis Procedures

A one-story steel frame has 4 identical columns, each with I = 800 in.^4, E = 29,000 ksi and height 14 ft. The columns are fixed at the base and fixed against rotation at the top by a rigid girder. What is the lateral stiffness of the story?

  • a.58.7 kips/in.
  • b.157.4 kips/in.
  • c.187.9 kips/in.
  • d.234.9 kips/in.✓

Each column contributes k = 12EI/h^3 (fixed-fixed): 12 x 29,000 x 800/(168)^3 = 58.7 kips/in. For 4 columns in parallel, k = 234.9 kips/in. The coefficient 3 would apply if the top were pinned, a fourfold difference in stiffness.

Seismic Analysis Procedures

A one-story steel frame has 6 identical columns, each with I = 500 in.^4, E = 29,000 ksi and height 12 ft. The columns are fixed at the base and pinned at the top. What is the lateral stiffness of the story?

  • a.14.6 kips/in.
  • b.87.4 kips/in.✓
  • c.125.9 kips/in.
  • d.349.6 kips/in.

Each column contributes k = 3EI/h^3 (cantilever, fixed-pinned): 3 x 29,000 x 500/(144)^3 = 14.6 kips/in. For 6 columns in parallel, k = 87.4 kips/in. The coefficient 12 would apply if the top were restrained against rotation, a fourfold difference in stiffness.

Seismic Analysis Procedures

What is meant by a continuous load path in seismic design?

  • a.Inertial forces can be traced through connected elements from their origin to the foundation✓
  • b.The same lateral system type is used in both of the principal plan directions
  • c.Every wall in the building is continuous without openings from foundation to roof
  • d.Gravity loads are carried by the shortest possible route from the roof framing down to the footings

ASCE 7-16 Section 12.1.3 requires a continuous load path with adequate strength and stiffness to transfer all forces from the point of application to the final point of resistance: diaphragm to collectors to walls or frames to foundation to soil. Any missing link defeats the whole system.

Seismic Analysis Procedures

In a horizontal diaphragm analogous to a deep beam, which elements resist the bending moment?

  • a.The sheathing at midspan
  • b.The hold-downs at the wall ends
  • c.The collectors at the shear walls
  • d.The chords at the diaphragm edges✓

Diaphragm sheathing acts like a beam web carrying shear, while chords (edge members perpendicular to the load, such as top plates, ledgers or wall reinforcing) act like flanges carrying tension and compression. Collectors transfer shear to the vertical elements; hold-downs resist shear wall overturning.

Seismic Analysis Procedures

What is the function of a collector (drag strut)?

  • a.To brace a wall panel against out-of-plane wind and seismic load
  • b.To resist overturning uplift at the end posts of a shear wall
  • c.To gather diaphragm shear and deliver it to the vertical lateral elements✓
  • d.To resist diaphragm bending by acting as the tension or compression flange

A collector runs parallel to the applied force and transfers diaphragm shear from areas with no wall or frame into the vertical elements (ASCE 7-16 Section 12.10.2). Chords resist diaphragm flexure, hold-downs resist wall overturning, and wall anchors handle out-of-plane forces.

Seismic Analysis Procedures

How does a flexible diaphragm distribute lateral force to the vertical resisting elements?

  • a.Entirely to the element nearest the center of mass
  • b.Equally to each element regardless of location
  • c.By tributary area, like simple beams between supports✓
  • d.By relative rigidity of the vertical elements

A flexible diaphragm cannot enforce equal displacements, so each wall line receives the load tributary to it and no torsion is transmitted. Rigidity-based distribution, including torsion, is the rigid diaphragm model.

Seismic Analysis Procedures

A rigid-diaphragm building's center of mass does not coincide with its center of rigidity. What results under lateral load?

  • a.Torsion about the center of rigidity, adding shear to some walls✓
  • b.Reduced base shear, because eccentricity lengthens the period
  • c.No effect, because a rigid diaphragm cannot rotate in plan
  • d.Vertical uplift on all walls equal to the eccentricity times V

The inertial force acts through the center of mass while resistance acts through the center of rigidity; the offset creates an inherent torsional moment Mt = V x e (ASCE 7-16 Section 12.8.4.1), which the walls resist in proportion to their rigidity and distance from the center of rigidity.

Seismic Analysis Procedures

Accidental torsion is represented by displacing the center of mass each way by what distance?

  • a.5% of the building dimension perpendicular to the applied force✓
  • b.5% of the building dimension parallel to the direction of applied force
  • c.10% of the building height measured from the base
  • d.15% of the distance between the two outermost shear walls

ASCE 7-16 Section 12.8.4.2 assumes a displacement of the center of mass equal to 5% of the dimension of the structure perpendicular to the direction of the applied forces. It covers uncertainties in mass and stiffness distribution and torsional ground motion.

Seismic Analysis Procedures

In a torsional analysis, the torsional shear in a wall acts opposite to its direct shear. How is the wall designed in common practice?

  • a.For the torsional shear alone, ignoring the direct shear completely
  • b.For the direct shear minus the full value of the torsional shear
  • c.For the direct shear alone, without taking the torsional reduction✓
  • d.For zero shear, because the two components cancel one another

Because accidental eccentricity is taken in both directions, each wall is designed for the most severe case; where torsion would reduce the direct shear, the reduction is neglected so the wall is not under-designed if the actual eccentricity is on the other side.

Seismic Analysis Procedures

In Seismic Design Category D, when must orthogonal (bidirectional) load effects be considered for a column?

  • a.When the column is located anywhere within a building that has a flexible wood structural panel roof diaphragm
  • b.When the column supports only gravity framing in a building that has perimeter shear walls
  • c.When the column is taller than 12 ft, regardless of the framing that it participates in
  • d.When the column is part of two intersecting seismic force-resisting systems and carries significant axial load✓

ASCE 7-16 Section 12.5.4 requires columns or walls forming part of two or more intersecting systems with axial load from seismic forces exceeding 20% of design axial strength to be designed for the most critical direction, commonly by the 100% plus 30% combination of Section 12.5.3.1.

Seismic Analysis Procedures

Which combination is the usual way of satisfying the orthogonal combination procedure?

  • a.100% of forces in one direction plus 30% in the perpendicular direction✓
  • b.70% of forces in one direction plus 70% in the perpendicular direction
  • c.50% of forces in one direction plus 50% in the perpendicular direction
  • d.100% of forces in one direction plus 100% in the perpendicular direction

ASCE 7-16 Section 12.5.3.1(a) applies 100% of the forces for one direction plus 30% of the forces for the perpendicular direction, using whichever combination gives the larger effect. Peak responses in two directions are unlikely to coincide, so 100% plus 100% is overly severe.

Seismic Analysis Procedures

Which elements must be designed with the overstrength factor when a shear wall is discontinued and supported on columns below?

  • a.The columns, beams or slabs that support the discontinuous wall✓
  • b.The nonstructural partitions located in the story below the wall
  • c.The roof diaphragm sheathing located directly above the wall
  • d.The foundations of the unrelated walls in the perpendicular direction

ASCE 7-16 Section 12.3.3.3 requires structural elements supporting discontinuous walls or frames to be designed for seismic load effects including overstrength. The supporting elements must stay elastic while the wall above reaches its real strength; their failure would remove gravity support.

Seismic Analysis Procedures

With seismic load effects including overstrength, what value is used for the redundancy factor?

  • a.Rho is taken as 1.5
  • b.Rho is taken as 1.0✓
  • c.Rho is taken as 1.3
  • d.Rho equals the overstrength factor

ASCE 7-16 Section 12.3.4.1 lists members designed for load combinations with overstrength among the cases where rho = 1.0. Overstrength already estimates the maximum force the system can deliver, so a redundancy penalty on top is not required.

Seismic Analysis Procedures

For allowable stress design, which basic combination governs overturning (uplift) of a shear wall?

  • a.D + 0.75L + 0.525E
  • b.1.0D + 0.7E
  • c.1.4D + 1.0E
  • d.0.6D + 0.7E✓

ASCE 7-16 Section 2.4.5 pairs 0.6D with 0.7E (expanding to (0.6 - 0.14 SDS)D + 0.7 rho QE) to minimize the stabilizing dead load. Combinations with full D check maximum compression, and 1.4D is a strength-design gravity combination.

Seismic Analysis Procedures

Using the rigidity relationship, how does a fixed-fixed wall pier compare with a cantilever pier of the same dimensions?

  • a.Both have identical rigidity, because rigidity depends on the area only
  • b.The fixed-fixed pier is stiffer, because its flexural deflection term is smaller✓
  • c.The cantilever pier is stiffer, because it is free to rotate at the top
  • d.The fixed-fixed pier is more flexible, because it must bend in double curvature

For a rectangular pier the deflection is proportional to (h/d)^3 + 3(h/d) when fixed at both ends and 4(h/d)^3 + 3(h/d) when cantilevered. The shear term is identical, but the flexural term is one-quarter as large for the fixed-fixed case, so its rigidity (1/deflection) is higher.

Seismic Analysis Procedures

How is the lateral rigidity of a wall defined?

  • a.The ratio of the wall height to the wall plan length
  • b.The deflection that is produced by the wall's own weight
  • c.The area of the wall divided by the story height
  • d.The force required to produce a unit lateral deflection✓

Rigidity (stiffness) k = F/delta, the reciprocal of the deflection under a unit load. Aspect ratio h/d strongly influences rigidity but is not the rigidity itself; relative rigidities are what matter for distributing rigid-diaphragm forces.

Seismic Analysis Procedures

Several wall piers between openings act side by side along one wall line. How is the combined rigidity of the piers obtained?

  • a.By using the rigidity of the single most flexible pier
  • b.By adding the individual pier rigidities, since they are in parallel✓
  • c.By adding the individual pier deflections, since they are in series
  • d.By averaging the heights of the piers and using one pier

Piers connected by a common top spandrel or diaphragm deflect together, so they act in parallel and rigidities add. Deflections add for elements in series, such as a strip of piers stacked on a solid portion of wall below the openings.

Seismic Analysis Procedures

A one-story building has shear walls on only three sides (open front) and a wood diaphragm. How is lateral load toward the open side resisted?

  • a.By uplift of the roof sheathing nails along the open-front edge header
  • b.By diaphragm rotation, with the two side walls resisting the torsion as a couple✓
  • c.By the rear wall alone in direct shear, with no force in the side walls
  • d.By bending of the open-front gravity columns acting as the primary lateral system

With no wall line at the open front, load parallel to the rear wall is carried by the rear wall in direct shear, and the resulting eccentricity is resisted by a couple in the two side walls. SDPWS-2021 Section 4.2 limits the proportions and conditions for such open-front, cantilevered diaphragms.

Seismic Analysis Procedures

In the modal response spectrum procedure, to what value must the combined modal base shear be scaled if it is lower?

  • a.No scaling is required in ASCE 7-16
  • b.50% of the equivalent lateral force base shear
  • c.100% of the equivalent lateral force base shear✓
  • d.85% of the equivalent lateral force base shear

ASCE 7-16 Section 12.9.1.4.1 requires force results to be scaled up when the modal base shear is less than 100% of the ELF base shear; the 85% scaling was the rule in ASCE 7-10 and earlier. This keeps a computer model with a long period from producing unconservatively low forces.

Seismic Analysis Procedures

When may the equivalent lateral force distribution be used to design diaphragm collectors in SDC D without overstrength?

  • a.In structures braced by special reinforced concrete shear walls
  • b.In any structure with a rigid concrete diaphragm
  • c.In structures braced entirely by light-frame shear walls✓
  • d.In any structure assigned to Risk Category IV

ASCE 7-16 Section 12.10.2.1 requires overstrength for collectors in SDC C through F, with an exception for structures or portions braced entirely by light-frame shear walls, where collectors need only be designed for the diaphragm forces of Section 12.10.1.1.

Seismic Analysis Procedures

What is a subdiaphragm?

  • a.A portion of a larger diaphragm designed to transfer wall anchorage forces to the continuous crossties✓
  • b.A plywood overlay nailed on top of the existing roof sheathing in order to raise its shear capacity
  • c.A horizontal steel truss that replaces the sheathing in a long-span diaphragm
  • d.A secondary roof built below the main roof to carry suspended mechanical units

A subdiaphragm is a small diaphragm within the main one, with its own chords and shear capacity, that picks up out-of-plane wall anchorage forces and delivers them to continuous crossties. ASCE 7-16 Section 12.11.2.2.1 limits its length-to-width ratio to 2.5 to 1.

Seismic Analysis Procedures

What is the maximum length-to-width ratio of a structural subdiaphragm used for wall anchorage?

  • a.4 to 1
  • b.6 to 1
  • c.2.5 to 1✓
  • d.1 to 1

ASCE 7-16 Section 12.11.2.2.1 limits the subdiaphragm length-to-width ratio to 2.5 to 1. The limit keeps the subdiaphragm stiff enough to deliver anchorage forces to the main diaphragm crossties without excessive deformation.

Seismic Analysis Procedures

In a wood shear wall, what resists the overturning moment caused by the lateral force at the top of the wall?

  • a.The edge nailing of the sheathing to the top plates only
  • b.The roof diaphragm chord over the top of the wall line
  • c.Hold-downs and end posts, forming a tension-compression couple✓
  • d.The anchor bolts acting in shear along the length of the sill

The lateral force times wall height produces overturning resisted by tension in a hold-down (tie-down) at one end and compression in the end post at the other, less any dead load. Sill anchor bolts transfer the horizontal shear to the foundation, a separate job.

Seismic Analysis Procedures

For a wood structural panel shear wall, the tie-down tension force before dead load is approximately what?

  • a.Total shear divided by the wall height
  • b.Total shear times the wall length
  • c.Unit shear times the wall length
  • d.Unit shear times the wall height✓

Overturning moment = V x h, resisted by a couple with lever arm roughly the wall length b: T = Vh/b = (V/b)h = v x h. So the uplift equals unit shear times height. Multiplying by length instead gives the total wall shear, not the uplift.

Seismic Analysis Procedures

Which load combination gives the maximum compression on a column for strength design with seismic load?

  • a.(0.9 - 0.2 SDS)D + rho QE
  • b.(0.6 - 0.14 SDS)D + 0.7 rho QE + 0.75L
  • c.(1.2 + 0.2 SDS)D + rho QE + L + 0.2S✓
  • d.1.4D with no earthquake load

ASCE 7-16 Section 2.3.6 with Section 12.4.2: the additive combination 1.2D + Ev + Eh + L + 0.2S expands to (1.2 + 0.2 SDS)D + rho QE + L + 0.2S and maximizes compression. The 0.9D form minimizes dead load for uplift, and the 0.6D form is its ASD counterpart.