In the approximate period formula, from where is the structural height hn measured?
- a.From the base to the highest level of the seismic force-resisting system✓
- b.From the second floor to the midheight of the roof framing
- c.From the top of the lowest footing to the top of the highest parapet or screen
- d.From average grade to the top of rooftop mechanical screens
ASCE 7-16 Section 11.2 defines structural height as the vertical distance from the base to the highest level of the seismic force-resisting system (for sloped roofs, the average roof height). Parapets and screens are nonstructural components above that level and do not lengthen hn.
If a building's mass stays the same while its lateral stiffness is doubled, what happens to its fundamental period?
- a.It decreases by a factor of about 0.71✓
- b.It decreases by a factor of exactly 0.50
- c.It does not change, since mass is constant
- d.It increases by a factor of about 1.41
T = 2 pi sqrt(m/k), so period varies with the inverse square root of stiffness: doubling k multiplies T by 1/sqrt(2) = 0.71. Halving the period would need four times the stiffness, and a stiffer building always has a shorter, not longer, period.
How does adding mass to a building, with stiffness unchanged, affect its fundamental period?
- a.The period shortens
- b.The period becomes zero
- c.The period lengthens✓
- d.The period is unchanged
From T = 2 pi sqrt(m/k), period grows with the square root of mass. A heavier roof therefore lengthens the period, though the base shear usually still rises because V = CsW grows directly with weight.
Two otherwise identical buildings are designed with R = 8 and R = 4. How do their design base shears compare when the SDS/(R/Ie) expression governs?
- a.The R = 4 building has twice the base shear✓
- b.Both buildings have the same base shear
- c.The R = 8 building has twice the base shear
- d.The R = 4 building has four times the base shear
Cs = SDS/(R/Ie) is inversely proportional to R, so halving R doubles Cs and V. A higher R reflects a more ductile, better-detailed system that is allowed lower design forces; it never increases the force.
Why does the importance factor Ie of 1.5 for a hospital increase its design base shear?
- a.It corrects the mapped ground motion for near-fault effects
- b.It converts strength-level forces to allowable stress levels
- c.It accounts for the heavier equipment found in a hospital
- d.It lowers the effective R, limiting inelastic demand and damage✓
Cs = SDS/(R/Ie): Ie effectively reduces R, so the essential facility is designed for higher forces and will experience less inelastic deformation, improving the chance of remaining operational. Equipment weight is captured in W and near-fault effects in the mapped accelerations and S1-based minimum.
A computed period T longer than Cu x Ta is used in a drift check. Is this permitted?
- a.Yes, but only if the building is in Seismic Design Category B
- b.No; drift must always be checked using the approximate period Ta
- c.No; the upper limit Cu x Ta applies to every use of the period
- d.Yes; the upper limit on T applies to strength design, not to drift✓
ASCE 7-16 Section 12.8.6.2 permits drift to be computed with seismic forces based on the computed fundamental period without the Cu x Ta upper limit of Section 12.8.2. The cap exists to prevent unconservatively low design forces for strength.
For a moment-resisting frame building not exceeding 12 stories with story heights of at least 10 ft, what alternative approximate period is permitted?
- a.Ta = 0.1N, with N the number of stories✓
- b.Ta = N/100, with N the number of stories
- c.Ta = 0.5N, with N the number of stories
- d.Ta = 0.1hn, with hn the height in feet
ASCE 7-16 Eq. 12.8-8 allows Ta = 0.1N for steel or concrete moment frames of 12 stories or fewer with average story height of at least 10 ft. A 10-story frame is thus estimated at 1.0 s; 0.5N or 0.1hn would give absurdly long periods.
Which coefficient for the upper limit on calculated period (Cu) applies where SD1 is 0.4g or greater?
- a.1.4✓
- b.1.0
- c.2.0
- d.1.7
ASCE 7-16 Table 12.8-1 gives Cu = 1.4 for SD1 of 0.4g or more, rising to 1.7 for SD1 of 0.1g or less. In high-seismic California sites, the computed period is therefore capped at 1.4Ta for strength design.
Under the equivalent lateral force procedure, how are lateral forces distributed over the height of a short-period (T of 0.5 s or less) building with equal floor weights?
- a.Entirely as one concentrated force at the roof
- b.Uniformly, with the same force at every level
- c.Linearly decreasing with height, largest at level 2
- d.Linearly increasing with height, largest at the roof✓
With k = 1 (ASCE 7-16 Section 12.8.3), Fx is proportional to wx hx, giving an inverted-triangle pattern that mimics first-mode response. A uniform pattern ignores the larger accelerations at upper levels, and a single roof force applies only to a one-story structure.
What is the lower bound on the diaphragm design force Fpx?
- a.0.044 SDS Ie wpx
- b.0.2 SDS Ie wpx✓
- c.0.4 SDS Ie wpx
- d.0.1 SDS Ie wpx
ASCE 7-16 Eq. 12.10-2 sets the minimum at 0.2 SDS Ie wpx, and Eq. 12.10-3 says the force need not exceed 0.4 SDS Ie wpx. The 0.044 SDS Ie coefficient is the minimum base shear coefficient, a different check.
Why can the diaphragm design force at a lower level exceed the story force Fx from the vertical distribution at that level?
- a.Lower floors are always heavier than the roof and so are amplified by R
- b.The code doubles the lower-level forces to account for foundation rocking
- c.Floor accelerations at lower levels are higher than the first-mode pattern implies✓
- d.Lower diaphragms always carry the accumulated story shear from every level above them
The Fx pattern is tuned to give correct story shears, but it underestimates peak accelerations of individual lower floors, where higher modes matter. Eq. 12.10-1 with its 0.2 SDS Ie wpx floor addresses that. Diaphragms do not accumulate story shear; each resists the inertia of its own level plus any transfer forces.
The minimum out-of-plane design force for a structural wall is 0.4 SDS Ie times the wall weight, but not less than what value?
- a.10% of the weight of the wall✓
- b.5% of the weight of the wall
- c.40% of the weight of the wall
- d.20% of the weight of the wall
ASCE 7-16 Section 12.11.1 sets the floor at 10% of the wall weight. The 5% value appears in the minimum connection force for beams and girders (Section 12.1.4), and 0.2 is the floor coefficient for wall anchorage forces, which are a separate requirement.
In the wall anchorage force equation, what value of the amplification factor ka applies when the diaphragm is rigid?
- a.0.5
- b.2.0
- c.1.5
- d.1.0✓
ASCE 7-16 Section 12.11.2.1: ka = 1.0 + Lf/100 for flexible diaphragms (maximum 2.0), and ka = 1.0 for diaphragms that are not flexible. Flexible diaphragms amplify wall accelerations at midspan, which is why they are penalized.
For wall anchorage to a flexible diaphragm, what does the term Lf represent?
- a.The spacing of the wall anchors measured along the wall
- b.The diaphragm span between the vertical elements that support it✓
- c.The height of the wall from the foundation to the parapet
- d.The length of the anchor embedment into the concrete or masonry wall
ASCE 7-16 Section 12.11.2.1 defines Lf as the span, in feet, of a flexible diaphragm that provides lateral support for the wall, measured between vertical elements that support the diaphragm in the direction considered. Longer spans mean more diaphragm amplification, up to ka = 2.0 at 100 ft.
Wall anchors to a diaphragm are spaced more than 4 ft apart. What additional requirement applies to the wall?
- a.The wall anchorage force may be reduced in proportion to spacing
- b.The wall must be designed to span in bending between the anchors✓
- c.The wall must be post-tensioned along the line of the anchors
- d.The wall must be thickened to at least 12 in. over its full height
ASCE 7-16 Section 12.11.2 requires structural walls to be designed to resist bending between anchors where the anchor spacing exceeds 4 ft. Wider spacing concentrates force; it does not reduce the anchorage demand, and no specific thickness or post-tensioning is mandated.
Which diaphragm may be idealized as rigid without calculation?
- a.A wood structural panel roof over a one-story light-frame warehouse with long wall spacing
- b.Any diaphragm whose deflection is more than twice the average story drift
- c.A concrete slab with span-to-depth ratio of 3 or less and no horizontal irregularity✓
- d.An untopped steel deck roof spanning between tilt-up concrete wall panels
ASCE 7-16 Section 12.3.1.2 permits concrete slabs or concrete-filled metal deck with span-to-depth of 3 or less in structures without horizontal irregularities to be idealized as rigid. Untopped steel deck and wood panel diaphragms are the usual flexible cases, and a deflection ratio above 2 is the calculated definition of flexible.
By calculation, a diaphragm is flexible when its maximum in-plane deflection exceeds what?
- a.One-half of the average drift of the adjoining vertical elements
- b.Two times the average drift of the adjoining vertical elements✓
- c.The allowable story drift given for the building's risk category
- d.Ten times the elastic displacement of the stiffest shear wall
ASCE 7-16 Section 12.3.1.3: a diaphragm is permitted to be idealized as flexible where the computed maximum in-plane diaphragm deflection is more than two times the average story drift of adjoining vertical elements under the equivalent lateral force loading.
At what location is the 'base' of a structure for computing base shear?
- a.The elevation of the roof, where the largest lateral force is applied
- b.The level of the lowest basement slab in every case, whatever the surrounding soil conditions
- c.The level at which horizontal ground motions are considered imparted to the structure✓
- d.The midheight of the first story above the exterior finished grade
ASCE 7-16 Section 11.2 defines the base as the level at which the horizontal seismic ground motions are considered to be imparted to the structure. It is often grade or the top of a stiff basement, not automatically the lowest slab.
For allowable stress design, by what factor is the strength-level earthquake load effect E multiplied in the basic load combinations?
- a.1.4
- b.0.6
- c.0.7✓
- d.1.0
ASCE 7-16 Section 2.4.5 uses 0.7E in the ASD seismic combinations because the seismic forces of Chapter 12 are strength-level. The 0.6 factor applies to dead load in the ASD overturning combination, and 1.4 would be the inverse conversion.
Where SDS is 0.125g or less, how may the vertical seismic load effect Ev be treated?
- a.It is permitted to be taken as zero✓
- b.It must be doubled for all members
- c.It replaces the horizontal effect Eh
- d.It must be taken as 0.2D regardless
ASCE 7-16 Section 12.4.2.2 permits Ev = 0 where SDS is 0.125 or less (and in certain foundation overturning checks). Otherwise Ev = 0.2 SDS D acts with the horizontal effect, adding to or subtracting from dead load.
A regular five-story Risk Category II building has a period of 0.4 s and qualifies under the special short-period provision. What does ASCE 7-16 permit when computing Cs?
- a.Cs may be calculated with R increased by 50%
- b.Cs may be calculated using a value of 1.5 for Ss✓
- c.Cs may be calculated using a value of 0.5 for S1
- d.Cs may be taken as 0.01 regardless of the site
ASCE 7-16 Section 12.8.1.3 lets regular structures of five stories or fewer with T of 0.5 s or less (and meeting the other listed conditions) compute Cs with Ss capped at 1.5, which caps design forces for short buildings at very high-Ss sites. It does not alter R or the minimum Cs.
In the equivalent lateral force procedure, the overturning moment at a given level is computed from what?
- a.The lateral forces above that level times their heights above it✓
- b.The diaphragm design force times the diaphragm span length
- c.The story weight at that level times the design story drift at that level
- d.The total base shear times the full height of the building
ASCE 7-16 Section 12.8.5: the structure is designed for overturning from the forces Fx of Section 12.8.3, so the moment at level x is the sum of each higher force times its height above level x. Using V times the full height ignores that the resultant acts at roughly two-thirds height.
Which seismic response coefficient minimum applies to every building regardless of S1?
- a.Cs not less than 0.044 SDS Ie, and not less than 0.01✓
- b.Cs not less than 0.5 S1/(R/Ie) at every single site
- c.Cs not less than 0.30 SDS Ie, and not less than 0.03
- d.Cs not less than SD1/(T R/Ie), and not less than 0.10
ASCE 7-16 Eq. 12.8-5 sets the universal floor at 0.044 SDS Ie, at least 0.01. The 0.5 S1/(R/Ie) floor (Eq. 12.8-6) applies only where S1 is 0.6g or more, and the SD1/(T R/Ie) expression is an upper limit, not a minimum.
Which statement about the approximate period Ta is correct?
- a.It must be multiplied by Cu before it is used in base shear
- b.It may be used only for buildings taller than 160 ft in height
- c.It is valid only when a modal response spectrum analysis is also performed
- d.It may be used directly as the design period without any analysis✓
ASCE 7-16 Section 12.8.2 permits the approximate period Ta from Section 12.8.2.1 to be used directly as the fundamental period, as an alternative to a substantiated structural analysis. Cu x Ta is only the upper limit on an analytically computed period; multiplying Ta by Cu without an analysis is a common error.
A two-story building's first-story shear walls resist the forces from which levels?
- a.The second-floor force only
- b.The roof force plus the second-floor force✓
- c.The roof force only
- d.Half of the roof force plus the floor force
Story shear is cumulative (ASCE 7-16 Eq. 12.8-13): the first story carries all lateral forces applied at and above the second floor, which here means the roof force plus the second-floor force. The second-story walls carry only the roof force.
Which change will reduce the equivalent lateral force base shear of a building at a given site?
- a.Adding a heavy concrete topping at each floor
- b.Selecting a more ductile system with a higher R✓
- c.Adding stiffness to shorten a 1.5 s period
- d.Changing the occupancy to Risk Category IV
V = CsW with Cs inversely proportional to R, so a higher-R system lowers the design force (at the cost of stricter detailing). Added weight raises W, Risk Category IV raises Ie, and for a period on the descending branch a shorter period raises Cs.
For which building is the equivalent lateral force procedure NOT permitted in Seismic Design Category D?
- a.A 300-ft-tall building with T greater than 3.5Ts✓
- b.A regular 100-ft building with T less than 3.5Ts
- c.A two-story light-frame Risk Category II building
- d.A regular three-story Risk Category I building
ASCE 7-16 Table 12.6-1 permits ELF for light-frame construction, for buildings up to 160 ft, and for taller regular buildings with T below 3.5Ts. A tall building with T above 3.5Ts has significant higher-mode response, so modal response spectrum or response history analysis is required.
Which statement about wall anchorage force and out-of-plane wall force is correct?
- a.Anchorage force applies only to walls in Seismic Design Category A
- b.Both the wall and the anchors always use the identical design force
- c.Anchorage is designed for the larger, separately specified anchorage force✓
- d.Anchors use one-half of the wall's own out-of-plane force as their design value
ASCE 7-16 treats them separately: Section 12.11.1 gives the force for designing the wall itself (0.4 SDS Ie times wall weight, at least 10%), while Section 12.11.2.1 gives the anchorage force with the ka amplifier and a 0.2 ka Ie Wp floor. Connections get the higher demand because their failure is brittle and causes collapse.