Texas Master Plumber Exam Cheat Sheet (2026)
A free, printable Texas Master Plumber exam cheat sheet: the 102 highest-yield points to know, grouped into 7 sections that follow the exam's content areas.
- Free to read, print and keep — no signup, no email, no paywall.
- 102 of the 102 points carry a citation to the rule they come from.
- The real Texas Master Plumber exam: 308 questions · 360 minutes · 70% to pass.
- Prints from your browser (Ctrl-P, or Cmd-P on a Mac) — the navigation, buttons and links drop out of the printed copy.
- 250 free Texas Master Plumber practice questions on the same material, every one explained.
Plumbing License Law and Board Rules
- Eligibility
- Two years as a journeyman, or one year after an approved apprenticeship programme.· Tex. Occ. Code §1301.002
- Insurance
- Certificate filed before acting as RMP; at least $300,000 for all claims in a one-year period.· Tex. Occ. Code §§1301.3576, 1301.552
- One company
- An RMP acts for one plumbing company; a change is reported in writing within 10 business days.· 22 TAC §367.5
- Advertising
- A company that offers plumbing must secure the services of an RMP.· Tex. Occ. Code §1301.351; 22 TAC §367.9
- Invoice
- Given to the customer on completion, even where there is no charge.· 22 TAC §367.3
- Vehicles
- Both sides, letters at least 2 inches high.· 22 TAC §367.10
- Insurance enquiries
- Answered within 30 days of a written request.· 22 TAC §367.6
- Address change
- Reported to the Board within 30 days.· 22 TAC §365.8
- Endorsements
- Medical gas: master or journeyman with the endorsement. Sprinklers: NFPA 13D, by the endorsement holder.· Tex. Occ. Code §§1301.356, 1301.3565; 22 TAC §367.8
- Continuing education
- 6 hours a year, 3 on health protection, energy conservation and water conservation.· Tex. Occ. Code §1301.404
- Late renewal
- 90 days or less: one and a half times the fee; two years or more: new licence and exam.· Tex. Occ. Code §1301.403
- Administrative penalty
- Up to $5,000 per violation, each day separate; 20 days to respond to the notice.· Tex. Occ. Code §§1301.702, 1301.704; 22 TAC §367.17
- Restitution
- Limited to the amount the customer paid for the regulated service.· Tex. Occ. Code §1301.5071
- Complaints
- Parties are updated at least quarterly until final disposition.· Tex. Occ. Code §1301.303
- Retakes
- Pass mark 70%; waiting periods lengthen after each failure.· 22 TAC §363.22
- Adopted codes
- UPC and IPC, 2018 editions, with the IFGC and IRC.· Tex. Occ. Code §1301.255; 22 TAC §367.2
- Cities
- More than 5,000 inhabitants must regulate plumbing by ordinance.· Tex. Occ. Code §1301.551
Plumbing Codes: Design and Commercial Systems
- Occupant split
- 50 percent male, 50 percent female.· IPC §403.1.1
- Separate facilities
- Not required with 15 or fewer occupants.· IPC §403.2
- Covered malls
- Path of travel to toilets not more than 300 feet.· IPC §403.3.4
- Hot water length
- 50 feet of developed length from the source unless recirculated or heat traced.· IPC §607.2
- Fire sprinklers
- Double check assembly; reduced pressure principle assembly where antifreeze or additives are used.· IPC §608.16.4
- Non-potable piping
- Identified by colour, tags or tape at intervals of 25 feet or less.· IPC §608.8
- Branch interval
- A vertical length of stack of at least 8 feet.· IPC §202
- Vent stack
- Required for five or more branch intervals; connects at or below the lowest branch.· IPC §§904.2, 904.4
- Relief vents
- Each tenth interval, counted from the top, in buildings over 10 branch intervals.· IPC §908.1
- Base of stack
- No horizontal branch within 10 stack diameters downstream.· IPC §711.1
- Sewage ejectors
- Pass 2-inch solids unless a grinder; discharge through a wye from the top; sump vent 1-1/4 inches minimum.· IPC §§712.3.5, 712.4.2, 906.5
- Building sewer
- Manholes every 200 feet on sewers 8 inches and larger.· IPC §708.1.2
- Rainfall rate
- 100-year, 1-hour storm for the location.· IPC §1106.1
- Secondary drains
- Required where water would be trapped; separate piping to a visible point above grade.· IPC §§1108.1, 1108.2
- Subsoil drains
- 4 inches minimum.· IPC §1111.1
- Storm sump pit
- 18 inches in diameter and 24 inches deep.· IPC §1113.1.2
- Grease interceptors
- Rated in gallons per minute; flow control limits the rate.· IPC §1003.3.4
- Medical gas
- Installed to NFPA 99.· IPC §1202.1
- Air test
- 5 psi (10 inches of mercury) for 15 minutes; not on plastic pipe.· IPC §312.3
- Final test
- Smoke or peppermint at 1 inch of water column, where required.· IPC §312.4
- Alternative design
- Documents from a registered design professional.· IPC §316
Water Heaters
- Relief setting
- Not above the tank's rated working pressure or 150 psi, whichever is less.· IPC §504.4
- Sensing element
- In the top 6 inches of the tank.· IPC §504.5
- Discharge pipe
- No valve or tee; ends not more than 6 inches above the floor or receptor.· IPC §504.6
- Pan drain
- 3/4 inch minimum.· IPC §504.7.1
- Thermal expansion
- Controlled where a backflow preventer or check valve closes the system.· IPC §607.3
- Attic access
- Passageway not more than 20 feet long to the heater.· IPC §502.3
- Garages
- Ignition source 18 inches above the floor unless listed as flammable vapour ignition resistant.· IFGC §305.3
- Indoor air
- 50 cubic feet of room volume per 1,000 Btu/h.· IFGC §304.5.1
- Outdoor air, vertical ducts
- 1 square inch per 4,000 Btu/h for each opening.· IFGC §304.6.1
- Single-wall connector
- 6 inches from combustibles; horizontal run limited to 75 percent of the vent height.· IFGC §§503.10.5, 503.10.9
- Type B vent
- Terminates at least 5 feet above the draft hood.· IFGC §503.6.5
- Plastic vent pipe
- As specified by the appliance manufacturer.· IFGC §503.4.1
OSHA Construction Safety
- Egress
- Ladder, stairway or ramp in trenches 4 feet or deeper, within 25 feet of lateral travel.· 29 CFR 1926.651(c)(2)
- Protective systems
- Required at 5 feet; designed by a registered professional engineer above 20 feet.· 29 CFR 1926.652
- Spoil
- Kept at least 2 feet from the edge.· 29 CFR 1926.651(j)(2)
- Atmosphere
- Tested where hazards are expected in excavations over 4 feet; oxygen below 19.5 percent is deficient; flammable gas kept to 20 percent of the lower flammable limit.· 29 CFR 1926.651(g)
- Slopes
- Type A 3/4 to 1; Type B 1 to 1; Type C 1-1/2 to 1.· 29 CFR 1926 Subpart P, Appendix B
- Shields
- Excavation no more than 2 feet below the bottom of the shield.· 29 CFR 1926.652(g)(2)
- Fall protection
- Required more than 10 feet above a lower level.· 29 CFR 1926.451(g)(1)
- Tipping
- Supported scaffolds taller than 4 times the base width are tied, guyed or braced.· 29 CFR 1926.451(c)(1)
- Access
- Required where the platform is more than 2 feet above or below the access point.· 29 CFR 1926.451(e)(1)
- Power lines
- 10 feet from uninsulated lines under 50 kV.· 29 CFR 1926.451(f)(6)
- Toeboards
- At least 3-1/2 inches high.· 29 CFR 1926.451(h)(4)
- Storage separation
- Oxygen 20 feet from fuel gas, or a 5-foot noncombustible barrier rated one-half hour.· 29 CFR 1926.350(a)(10)
- Fuel-gas valve
- Opened no more than 1-1/2 turns.· 29 CFR 1926.350(d)
- Compressed air
- Cleaning only below 30 psi with chip guarding and protective equipment.· 29 CFR 1926.302(b)(4)
- Electric tools
- Double insulated or grounded.· 29 CFR 1926.302(a)
- Grinder work rest
- Within 1/8 inch of the wheel.· 29 CFR 1926.303(c)(2)
Texas Accessibility Standards
- Centreline
- 16 to 18 inches from the side wall.· 2012 TAS §604.2
- Seat height
- 17 to 19 inches.· 2012 TAS §604.4
- Clearance
- 60 inches from the side wall, 56 inches from the rear wall.· 2012 TAS §604.3
- Grab bars
- Side 42 inches, rear 36 inches; 33 to 36 inches high; 1-1/2 inches off the wall; 250 pounds.· 2012 TAS §§604.5, 609
- Compartments
- 60 inches wide; 56 inches deep for wall-hung and 59 inches for floor-mounted water closets.· 2012 TAS §604.8.1.1
- Ambulatory compartment
- Added where six or more water closets and urinals are provided.· 2012 TAS §213.3.1
- Lavatory rim
- 34 inches maximum.· 2012 TAS §606.3
- Knee clearance
- 27 inches high at the front.· 2012 TAS §306.3
- Exposed pipes
- Insulated or configured to protect against contact.· 2012 TAS §606.5
- Metering faucets
- Stay open at least 10 seconds.· 2012 TAS §606.4
- Urinal rim
- 17 inches maximum.· 2012 TAS §605.2
- Drinking fountain
- Spout 36 inches maximum; flow at least 4 inches high.· 2012 TAS §602
- Transfer shower
- 36 by 36 inches.· 2012 TAS §608.2.1
- Roll-in shower
- 30 by 60 inches minimum; threshold 1/2 inch maximum.· 2012 TAS §§608.2.2, 608.7
- Spray unit
- Hose at least 59 inches; water 120°F maximum.· 2012 TAS §608.6
- Reach range
- 15 to 48 inches for an unobstructed forward reach.· 2012 TAS §308.2.1
LP Gas
- Specific gravity
- About 1.5 (air is 1.0).· NFPA 54; NFPA 58
- Heating value
- About 2,500 Btu per cubic foot of vapour; about 91,500 Btu per gallon of liquid.· NFPA 58 annex
- Appliance pressure
- About 11 inches of water column, after two-stage regulation.· NFPA 54 sizing tables
- Odorant
- Ethyl mercaptan.· NFPA 58
- Test pressure
- 1-1/2 times working pressure, not less than 3 psi.· NFPA 54 Ch. 8
- Prohibited locations
- Circulating air ducts, clothes chutes, chimneys, elevator shafts.· NFPA 54 Ch. 7
- Concealed fittings
- No unions, bushings or compression couplings.· NFPA 54 Ch. 7
- Plastic pipe
- Outdoors and underground only.· NFPA 54 Ch. 7
- Cover
- 12 inches minimum underground.· NFPA 54 Ch. 7
- Unvented heaters
- Bathroom 6,000 Btu/h; bedroom 10,000 Btu/h; oxygen depletion shutoff required.· NFPA 54 Ch. 10
- Connectors
- Listed, 6 feet maximum, not concealed.· NFPA 54 Ch. 9
- Clothes dryers
- Exhaust outdoors, never into a vent or chimney; no screws into the airway.· NFPA 54 Ch. 10
- Licensing
- Railroad Commission of Texas, LP-Gas Safety Rules.· 16 TAC Ch. 9
Plumbing Mathematics
- Head to pressure
- Feet of head × 0.433 = psi.· General hydraulics
- Pressure to head
- psi × 2.31 = feet of head.· General hydraulics
- Tank volume
- Cubic feet × 7.48 = gallons.· General hydraulics
- Weight of water
- Gallons × 8.33 = pounds.· General hydraulics
- Fall
- Grade (inches per foot) × run (feet).· IPC §704.1
- 45-degree offset
- Travel = offset × 1.414.· Trade mathematics
- Continuous flow
- Each gallon per minute counts as 2 drainage fixture units.· IPC §709.3
Now prove you know them
Reading an outline is not the same as recalling it under exam pressure. Drill the free Texas Master Plumber questions to find the areas you keep missing, then sit a full timed mock.