PrepPass team · Verified against TSBPE — Master Plumber License · How we review

Free · printable · no signup

Texas Master Plumber Exam Cheat Sheet (2026)

A free, printable Texas Master Plumber exam cheat sheet: the 102 highest-yield points to know, grouped into 7 sections that follow the exam's content areas.

  • Free to read, print and keep — no signup, no email, no paywall.
  • 102 of the 102 points carry a citation to the rule they come from.
  • The real Texas Master Plumber exam: 308 questions · 360 minutes · 70% to pass.
  • Prints from your browser (Ctrl-P, or Cmd-P on a Mac) — the navigation, buttons and links drop out of the printed copy.
  • 250 free Texas Master Plumber practice questions on the same material, every one explained.

Plumbing License Law and Board Rules

Study →
Eligibility
Two years as a journeyman, or one year after an approved apprenticeship programme.· Tex. Occ. Code §1301.002
Insurance
Certificate filed before acting as RMP; at least $300,000 for all claims in a one-year period.· Tex. Occ. Code §§1301.3576, 1301.552
One company
An RMP acts for one plumbing company; a change is reported in writing within 10 business days.· 22 TAC §367.5
Advertising
A company that offers plumbing must secure the services of an RMP.· Tex. Occ. Code §1301.351; 22 TAC §367.9
Invoice
Given to the customer on completion, even where there is no charge.· 22 TAC §367.3
Vehicles
Both sides, letters at least 2 inches high.· 22 TAC §367.10
Insurance enquiries
Answered within 30 days of a written request.· 22 TAC §367.6
Address change
Reported to the Board within 30 days.· 22 TAC §365.8
Endorsements
Medical gas: master or journeyman with the endorsement. Sprinklers: NFPA 13D, by the endorsement holder.· Tex. Occ. Code §§1301.356, 1301.3565; 22 TAC §367.8
Continuing education
6 hours a year, 3 on health protection, energy conservation and water conservation.· Tex. Occ. Code §1301.404
Late renewal
90 days or less: one and a half times the fee; two years or more: new licence and exam.· Tex. Occ. Code §1301.403
Administrative penalty
Up to $5,000 per violation, each day separate; 20 days to respond to the notice.· Tex. Occ. Code §§1301.702, 1301.704; 22 TAC §367.17
Restitution
Limited to the amount the customer paid for the regulated service.· Tex. Occ. Code §1301.5071
Complaints
Parties are updated at least quarterly until final disposition.· Tex. Occ. Code §1301.303
Retakes
Pass mark 70%; waiting periods lengthen after each failure.· 22 TAC §363.22
Adopted codes
UPC and IPC, 2018 editions, with the IFGC and IRC.· Tex. Occ. Code §1301.255; 22 TAC §367.2
Cities
More than 5,000 inhabitants must regulate plumbing by ordinance.· Tex. Occ. Code §1301.551

Plumbing Codes: Design and Commercial Systems

Study →
Occupant split
50 percent male, 50 percent female.· IPC §403.1.1
Separate facilities
Not required with 15 or fewer occupants.· IPC §403.2
Covered malls
Path of travel to toilets not more than 300 feet.· IPC §403.3.4
Hot water length
50 feet of developed length from the source unless recirculated or heat traced.· IPC §607.2
Fire sprinklers
Double check assembly; reduced pressure principle assembly where antifreeze or additives are used.· IPC §608.16.4
Non-potable piping
Identified by colour, tags or tape at intervals of 25 feet or less.· IPC §608.8
Branch interval
A vertical length of stack of at least 8 feet.· IPC §202
Vent stack
Required for five or more branch intervals; connects at or below the lowest branch.· IPC §§904.2, 904.4
Relief vents
Each tenth interval, counted from the top, in buildings over 10 branch intervals.· IPC §908.1
Base of stack
No horizontal branch within 10 stack diameters downstream.· IPC §711.1
Sewage ejectors
Pass 2-inch solids unless a grinder; discharge through a wye from the top; sump vent 1-1/4 inches minimum.· IPC §§712.3.5, 712.4.2, 906.5
Building sewer
Manholes every 200 feet on sewers 8 inches and larger.· IPC §708.1.2
Rainfall rate
100-year, 1-hour storm for the location.· IPC §1106.1
Secondary drains
Required where water would be trapped; separate piping to a visible point above grade.· IPC §§1108.1, 1108.2
Subsoil drains
4 inches minimum.· IPC §1111.1
Storm sump pit
18 inches in diameter and 24 inches deep.· IPC §1113.1.2
Grease interceptors
Rated in gallons per minute; flow control limits the rate.· IPC §1003.3.4
Medical gas
Installed to NFPA 99.· IPC §1202.1
Air test
5 psi (10 inches of mercury) for 15 minutes; not on plastic pipe.· IPC §312.3
Final test
Smoke or peppermint at 1 inch of water column, where required.· IPC §312.4
Alternative design
Documents from a registered design professional.· IPC §316

Water Heaters

Study →
Relief setting
Not above the tank's rated working pressure or 150 psi, whichever is less.· IPC §504.4
Sensing element
In the top 6 inches of the tank.· IPC §504.5
Discharge pipe
No valve or tee; ends not more than 6 inches above the floor or receptor.· IPC §504.6
Pan drain
3/4 inch minimum.· IPC §504.7.1
Thermal expansion
Controlled where a backflow preventer or check valve closes the system.· IPC §607.3
Attic access
Passageway not more than 20 feet long to the heater.· IPC §502.3
Garages
Ignition source 18 inches above the floor unless listed as flammable vapour ignition resistant.· IFGC §305.3
Indoor air
50 cubic feet of room volume per 1,000 Btu/h.· IFGC §304.5.1
Outdoor air, vertical ducts
1 square inch per 4,000 Btu/h for each opening.· IFGC §304.6.1
Single-wall connector
6 inches from combustibles; horizontal run limited to 75 percent of the vent height.· IFGC §§503.10.5, 503.10.9
Type B vent
Terminates at least 5 feet above the draft hood.· IFGC §503.6.5
Plastic vent pipe
As specified by the appliance manufacturer.· IFGC §503.4.1

OSHA Construction Safety

Study →
Egress
Ladder, stairway or ramp in trenches 4 feet or deeper, within 25 feet of lateral travel.· 29 CFR 1926.651(c)(2)
Protective systems
Required at 5 feet; designed by a registered professional engineer above 20 feet.· 29 CFR 1926.652
Spoil
Kept at least 2 feet from the edge.· 29 CFR 1926.651(j)(2)
Atmosphere
Tested where hazards are expected in excavations over 4 feet; oxygen below 19.5 percent is deficient; flammable gas kept to 20 percent of the lower flammable limit.· 29 CFR 1926.651(g)
Slopes
Type A 3/4 to 1; Type B 1 to 1; Type C 1-1/2 to 1.· 29 CFR 1926 Subpart P, Appendix B
Shields
Excavation no more than 2 feet below the bottom of the shield.· 29 CFR 1926.652(g)(2)
Fall protection
Required more than 10 feet above a lower level.· 29 CFR 1926.451(g)(1)
Tipping
Supported scaffolds taller than 4 times the base width are tied, guyed or braced.· 29 CFR 1926.451(c)(1)
Access
Required where the platform is more than 2 feet above or below the access point.· 29 CFR 1926.451(e)(1)
Power lines
10 feet from uninsulated lines under 50 kV.· 29 CFR 1926.451(f)(6)
Toeboards
At least 3-1/2 inches high.· 29 CFR 1926.451(h)(4)
Storage separation
Oxygen 20 feet from fuel gas, or a 5-foot noncombustible barrier rated one-half hour.· 29 CFR 1926.350(a)(10)
Fuel-gas valve
Opened no more than 1-1/2 turns.· 29 CFR 1926.350(d)
Compressed air
Cleaning only below 30 psi with chip guarding and protective equipment.· 29 CFR 1926.302(b)(4)
Electric tools
Double insulated or grounded.· 29 CFR 1926.302(a)
Grinder work rest
Within 1/8 inch of the wheel.· 29 CFR 1926.303(c)(2)

Texas Accessibility Standards

Study →
Centreline
16 to 18 inches from the side wall.· 2012 TAS §604.2
Seat height
17 to 19 inches.· 2012 TAS §604.4
Clearance
60 inches from the side wall, 56 inches from the rear wall.· 2012 TAS §604.3
Grab bars
Side 42 inches, rear 36 inches; 33 to 36 inches high; 1-1/2 inches off the wall; 250 pounds.· 2012 TAS §§604.5, 609
Compartments
60 inches wide; 56 inches deep for wall-hung and 59 inches for floor-mounted water closets.· 2012 TAS §604.8.1.1
Ambulatory compartment
Added where six or more water closets and urinals are provided.· 2012 TAS §213.3.1
Lavatory rim
34 inches maximum.· 2012 TAS §606.3
Knee clearance
27 inches high at the front.· 2012 TAS §306.3
Exposed pipes
Insulated or configured to protect against contact.· 2012 TAS §606.5
Metering faucets
Stay open at least 10 seconds.· 2012 TAS §606.4
Urinal rim
17 inches maximum.· 2012 TAS §605.2
Drinking fountain
Spout 36 inches maximum; flow at least 4 inches high.· 2012 TAS §602
Transfer shower
36 by 36 inches.· 2012 TAS §608.2.1
Roll-in shower
30 by 60 inches minimum; threshold 1/2 inch maximum.· 2012 TAS §§608.2.2, 608.7
Spray unit
Hose at least 59 inches; water 120°F maximum.· 2012 TAS §608.6
Reach range
15 to 48 inches for an unobstructed forward reach.· 2012 TAS §308.2.1

LP Gas

Study →
Specific gravity
About 1.5 (air is 1.0).· NFPA 54; NFPA 58
Heating value
About 2,500 Btu per cubic foot of vapour; about 91,500 Btu per gallon of liquid.· NFPA 58 annex
Appliance pressure
About 11 inches of water column, after two-stage regulation.· NFPA 54 sizing tables
Odorant
Ethyl mercaptan.· NFPA 58
Test pressure
1-1/2 times working pressure, not less than 3 psi.· NFPA 54 Ch. 8
Prohibited locations
Circulating air ducts, clothes chutes, chimneys, elevator shafts.· NFPA 54 Ch. 7
Concealed fittings
No unions, bushings or compression couplings.· NFPA 54 Ch. 7
Plastic pipe
Outdoors and underground only.· NFPA 54 Ch. 7
Cover
12 inches minimum underground.· NFPA 54 Ch. 7
Unvented heaters
Bathroom 6,000 Btu/h; bedroom 10,000 Btu/h; oxygen depletion shutoff required.· NFPA 54 Ch. 10
Connectors
Listed, 6 feet maximum, not concealed.· NFPA 54 Ch. 9
Clothes dryers
Exhaust outdoors, never into a vent or chimney; no screws into the airway.· NFPA 54 Ch. 10
Licensing
Railroad Commission of Texas, LP-Gas Safety Rules.· 16 TAC Ch. 9

Plumbing Mathematics

Study →
Head to pressure
Feet of head × 0.433 = psi.· General hydraulics
Pressure to head
psi × 2.31 = feet of head.· General hydraulics
Tank volume
Cubic feet × 7.48 = gallons.· General hydraulics
Weight of water
Gallons × 8.33 = pounds.· General hydraulics
Fall
Grade (inches per foot) × run (feet).· IPC §704.1
45-degree offset
Travel = offset × 1.414.· Trade mathematics
Continuous flow
Each gallon per minute counts as 2 drainage fixture units.· IPC §709.3

Now prove you know them

Reading an outline is not the same as recalling it under exam pressure. Drill the free Texas Master Plumber questions to find the areas you keep missing, then sit a full timed mock.

Study aid, not a substitute for the official material — always confirm the current rule with TSBPE — Master Plumber License.