Texas Tradesman Plumber-Limited Exam — All Questions

30 questions

Sanitary Drainage

Under IRC §P3005.3, a horizontal drain pipe 2 inches in diameter must slope at not less than:

  • a.3 inches per foot
  • b.1/32 inch per foot
  • c.1 inch per foot
  • d.1/4 inch per foot✓

Horizontal drainage piping 2-1/2 inches or less in diameter is installed at a uniform slope of not less than 1/4 inch per foot.IRC §P3005.3

Sanitary Drainage

Under IRC §P3005.3, a horizontal drain pipe 3 inches in diameter or larger may slope at not less than:

  • a.1-1/2 inches per foot
  • b.2-1/2 inches per foot
  • c.1/8 inch per foot✓
  • d.1/64 inch per foot

Piping 3 inches and larger may be installed at 1/8 inch per foot; smaller piping needs 1/4 inch per foot to keep solids moving.IRC §P3005.3

Sanitary Drainage

A 3-inch building drain runs 40 feet at the minimum slope of 1/8 inch per foot. The total fall over the run is:

  • a.5 inches✓
  • b.10 inches
  • c.40 inches
  • d.1/2 inch

40 feet × 1/8 inch per foot = 5 inches. At 1/4 inch per foot the same run would fall 10 inches.IRC §P3005.3

Sanitary Drainage

Under IRC Table P3004.1, a lavatory is rated at how many drainage fixture units?

  • a.8
  • b.4
  • c.6
  • d.1✓

A lavatory is 1 dfu; bathtubs, showers, kitchen sinks and clothes washer standpipes are 2 dfu each.IRC Table P3004.1

Sanitary Drainage

Under IRC Table P3004.1, a 1.6-gallon-per-flush water closet is rated at:

  • a.12 drainage fixture units
  • b.1 drainage fixture unit
  • c.3 drainage fixture units✓
  • d.8 drainage fixture units

A water closet of 1.6 gallons per flush or less is 3 dfu; one that uses more than 1.6 gallons is 4 dfu.IRC Table P3004.1

Sanitary Drainage

Under IRC Table P3004.1, a full bathroom group with a 1.6-gallon water closet (water closet, lavatory, and bathtub or shower) is rated at:

  • a.5 drainage fixture units✓
  • b.20 drainage fixture units
  • c.2 drainage fixture units
  • d.12 drainage fixture units

A full-bath group is 5 dfu, less than the sum of its fixtures taken singly (3 + 1 + 2 = 6), because the fixtures are rarely all discharging at once.IRC Table P3004.1

Sanitary Drainage

Under IRC Table P3004.1, a kitchen sink with or without a dishwasher and food waste disposer is rated at:

  • a.10 drainage fixture units
  • b.2 drainage fixture units✓
  • c.8 drainage fixture units
  • d.6 drainage fixture units

A kitchen group (sink, dishwasher and disposer) is 2 dfu, and so is a kitchen sink alone.IRC Table P3004.1

Sanitary Drainage

Under IRC Table P3005.4.1, a 1-1/2 inch horizontal fixture branch may carry not more than:

  • a.12 drainage fixture units
  • b.3 drainage fixture units✓
  • c.48 drainage fixture units
  • d.20 drainage fixture units

A 1-1/2 inch horizontal branch carries up to 3 dfu, a 2-inch branch 6 dfu and a 3-inch branch 20 dfu.IRC Table P3005.4.1

Sanitary Drainage

Under IRC Table P3005.4.1, a 2-inch horizontal fixture branch may carry not more than:

  • a.6 drainage fixture units✓
  • b.42 drainage fixture units
  • c.1 drainage fixture unit
  • d.24 drainage fixture units

A 2-inch horizontal branch is limited to 6 dfu. It may not carry a water closet, which needs a 3-inch drain.IRC Table P3005.4.1

Sanitary Drainage

The drain from a water closet in a house must be at least:

  • a.1-1/2 inches in diameter
  • b.6 inches in diameter
  • c.3 inches in diameter✓
  • d.2 inches in diameter

Water closets discharge to a drain of at least 3 inches; the sizing tables bar water closets from 1-1/2 and 2-inch building drains and branches.IRC §P3005.4; Table P3005.4.2

Sanitary Drainage

Under IRC §P3005.1.6, the size of drainage piping in the direction of flow may NOT be:

  • a.Offset with wyes
  • b.Reduced✓
  • c.Increased
  • d.Kept the same

Drain piping is not reduced in size in the direction of flow; a smaller pipe downstream would catch solids from the larger one.IRC §P3005.1.6

Sanitary Drainage

Under IRC §P3005.2.2, cleanouts on a building drain and building sewer must be spaced not more than:

  • a.1,000 feet apart
  • b.10 feet apart
  • c.500 feet apart
  • d.100 feet apart✓

Horizontal drainage pipe has cleanouts at intervals of not more than 100 feet, measured along the developed length.IRC §P3005.2.2

Sanitary Drainage

Under IRC §P3005.2.3, a cleanout is required near:

  • a.The connection of every lavatory trap to its horizontal trap arm
  • b.The water service entrance, next to the main valve
  • c.The top of every vent stack, just below the roof
  • d.The junction of the building drain and the building sewer✓

A cleanout is installed at or near the junction of the building drain and building sewer, inside or outside the wall, so that the sewer can be rodded.IRC §P3005.2.3

Sanitary Drainage

Under IRC §P3005.2.4, a cleanout is required at a change of direction of the building drain or sewer that is greater than:

  • a.45 degrees✓
  • b.5 degrees
  • c.10 degrees
  • d.22-1/2 degrees

Cleanouts are installed at each change of direction greater than 45 degrees; where several changes occur within 40 feet, one cleanout may serve them.IRC §P3005.2.4

Sanitary Drainage

Under IRC §P3005.2.5, a cleanout on a 3-inch drain must be:

  • a.1 inch, with a reducing bushing in the fitting
  • b.1-1/2 inches, half the size of the pipe
  • c.6 inches, two sizes larger than the pipe
  • d.3 inches, the same nominal size as the pipe✓

Cleanouts are the same nominal size as the pipe they serve up to 4 inches; for larger pipe they are at least 4 inches.IRC §P3005.2.5

Sanitary Drainage

A cleanout plug on a 3-inch drain is hidden behind finished drywall with no opening. Under IRC §P3005.2.9, this is:

  • a.Not permitted, unless the plug is made of brass
  • b.Permitted, because the plug is on the drain side of the trap
  • c.Not permitted, because cleanouts must be accessible✓
  • d.Permitted, where the wall is on the top floor of the house

Cleanouts are accessible; concealed cleanouts are brought to the finished wall or floor or provided with an access cover.IRC §P3005.2.9

Sanitary Drainage

Under IRC Table P3005.1, which fitting may be used where a horizontal drain turns to vertical?

  • a.A double-tapped bushing
  • b.A running trap
  • c.A saddle fitting
  • d.A sanitary tee✓

Sanitary tees and quarter bends are permitted for horizontal-to-vertical changes. For vertical to horizontal and horizontal to horizontal, long-sweep fittings or wye and eighth-bend combinations are needed.IRC Table P3005.1

Sanitary Drainage

Under IRC Table P3005.1, a sanitary tee may NOT be used for which change of direction?

  • a.Horizontal to vertical
  • b.Horizontal to horizontal✓
  • c.A fixture arm to a stack
  • d.A dry vent takeoff

A sanitary tee's short sweep is acceptable only where the flow drops into a vertical pipe. On its back or side in a horizontal drain it causes stoppages, so a wye is used.IRC Table P3005.1

Sanitary Drainage

Under IRC §P3003.2, which joint is prohibited in a drainage system?

  • a.A shielded hubless coupling
  • b.A solvent-cemented PVC joint
  • c.A saddle-type fitting✓
  • d.A threaded cleanout plug

Prohibited joints include cement or concrete joints, mastic or hot-pour bituminous joints, saddle-type fittings and solvent-cement joints between different types of plastic pipe.IRC §P3003.2

Sanitary Drainage

An ABS drain is to be joined to a PVC drain. Under IRC §P3003, the correct joint is:

  • a.An approved transition coupling✓
  • b.A bead of silicone sealant in the hub
  • c.Ordinary ABS cement with a primer
  • d.Ordinary PVC cement with no primer

Solvent-cement joints between different types of plastic pipe are prohibited; joints between different materials are made with an approved adapter or transition fitting.IRC §§P3003.2, P3003.13

Sanitary Drainage

Under IRC §P3008.1, a backwater valve is required for fixtures whose flood level rims are:

  • a.More than 42 inches above the finished floor of the room
  • b.Within 5 feet of the building's water service entrance
  • c.Below the elevation of the manhole cover of the next upstream manhole✓
  • d.Above the elevation of the manhole cover of the next upstream manhole

Where fixture flood level rims are below the next upstream manhole cover in the public sewer, the fixtures are protected by a backwater valve. Fixtures above that level do not discharge through it.IRC §P3008.1

Sanitary Drainage

Under IRC §P3008, a backwater valve must be installed so that:

  • a.Its flapper is removed after the final inspection
  • b.Its working parts are accessible for service and repair✓
  • c.It is located on the vent side of the highest fixture trap
  • d.It is buried in the yard with no access cover

Backwater valves are installed so that access is provided to the working parts for cleaning and repair; a buried valve without an access cannot be maintained.IRC §P3008.4

Sanitary Drainage

Fixtures in a basement are below the building sewer and drain to a sewage ejector. Under IRC §P3007.1, the discharge line from the ejector needs:

  • a.A trap primer and a cleanout plug
  • b.A vacuum breaker and a hose bibb
  • c.A relief valve and a pressure gauge
  • d.A check valve and a full-open valve✓

The discharge pipe has a check valve to stop backflow into the sump and a full-open valve on the discharge side of the check valve so the pump can be serviced.IRC §P3007.1

Sanitary Drainage

Under IRC §P3007.3.2, a sewage sump pit in a house must be at least:

  • a.6 inches in diameter and 6 inches deep
  • b.10 inches in diameter and 12 inches deep
  • c.60 inches in diameter and 96 inches deep
  • d.18 inches in diameter and 24 inches deep✓

The sump pit is not less than 18 inches in diameter and 24 inches deep unless otherwise approved, with a gastight cover and a vent.IRC §P3007.3.2

Sanitary Drainage

Under IRC §P3007.6, a sewage ejector that serves a water closet must have a discharge pipe of at least:

  • a.1/2 inch
  • b.2 inches✓
  • c.3/4 inch
  • d.1 inch

A sewage pump or ejector that passes 2-inch solids has a minimum discharge of 2 inches; grinder pumps may use a 1-1/4 inch discharge.IRC Table P3007.6

Sanitary Drainage

Under IRC §P3002.1, which material is approved for above-ground drain, waste and vent piping in a house?

  • a.Garden-hose vinyl tubing
  • b.Galvanized sheet-metal duct
  • c.Schedule 40 PVC DWV pipe✓
  • d.Corrugated polyethylene drain tile

Approved above-ground DWV materials include ABS and PVC Schedule 40 plastic pipe, cast iron, copper DWV tube and galvanized steel.IRC Table P3002.1(1)

Sanitary Drainage

A dishwasher and a food waste disposer are added to a kitchen sink. Under IRC Table P3201.7, the trap serving the sink must be at least:

  • a.4-1/2 inches
  • b.3-1/2 inches
  • c.1-1/2 inches✓
  • d.3/4 inch

A kitchen sink with one or two traps, with or without a dishwasher and disposer, uses a 1-1/2 inch trap.IRC Table P3201.7

Sanitary Drainage

Under IRC §P2719.1, a floor drain in a house must have a waste outlet of at least:

  • a.1 inch in diameter
  • b.2 inches in diameter✓
  • c.3/4 inch in diameter
  • d.1/2 inch in diameter

Floor drains have waste outlets not less than 2 inches in diameter and a removable strainer.IRC §P2719.1

Sanitary Drainage

A building sewer is laid from a house to the city tap. Under IRC §P2604.1, the pipe must be bedded:

  • a.On a firm, continuous bearing along its full length✓
  • b.On bricks spaced every 4 feet along the trench
  • c.On the hubs only, with the barrel bridging between
  • d.On loose rock larger than the pipe diameter

Piping is laid on a firm bed for its entire length; where the trench is over-excavated or rocky, it is brought back to grade with compacted sand or fine gravel. Blocking that leaves the barrel unsupported is not permitted.IRC §P2604.1

Sanitary Drainage

A plumber needs to add a branch to an existing cast-iron stack in a house. Which method is consistent with IRC §P3003?

  • a.Strapping a saddle fitting over a hole cut in the stack
  • b.Packing mortar around a pipe pushed into a hole in the stack
  • c.Gluing a PVC stub into the hole with ABS cement
  • d.Cutting in a fitting and joining it with shielded couplings✓

A fitting is cut in and joined with approved mechanical couplings. Saddle fittings, cement or mortar joints and mismatched solvent cements are all prohibited joints.IRC §§P3003.2, P3003.13