Texas Tradesman Plumber-Limited Exam — All Questions

29 questions

Water Supply and Distribution

Static water pressure at a house measures 105 psi. Under IRC §P2903.3.1, the plumber must install:

  • a.A backwater valve on the water service
  • b.A booster pump to bring it to 150 psi or more at the heater
  • c.A larger water meter with a bypass line
  • d.A pressure-reducing valve to bring it to 80 psi or less✓

Where the main pressure exceeds 80 psi static, an approved pressure-reducing valve is installed on the service or main supply to limit the pressure to 80 psi.IRC §P2903.3.1

Water Supply and Distribution

Under IRC §P2903.7, the water service pipe to a house must be at least:

  • a.3 inches in diameter
  • b.1/4 inch in diameter
  • c.3/4 inch in diameter✓
  • d.2 inches in diameter

The water service pipe is sized for the demand but is not less than 3/4 inch in diameter.IRC §P2903.7

Water Supply and Distribution

Under IRC §P2903.9.1, each dwelling unit must have a main water shutoff valve that is:

  • a.A stop valve located under the kitchen sink only
  • b.A check valve located at the water heater inlet
  • c.A globe valve buried in the yard near the meter with no access box
  • d.An accessible full-open valve near the entrance of the water service✓

Each dwelling unit has an accessible main shutoff valve of the full-open type near the entrance of the water service, with provision for drainage where freezing can occur.IRC §P2903.9.1

Water Supply and Distribution

Under IRC §P2903.9.3, a shutoff valve is required on the fixture supply to each plumbing fixture in a house EXCEPT:

  • a.Water closets and bidets
  • b.Bathtubs and showers✓
  • c.Kitchen sinks
  • d.Lavatories

Fixture valves are required on the supply to each fixture other than bathtubs and showers, whose supplies are usually concealed in the wall.IRC §P2903.9.3

Water Supply and Distribution

Under IRC §P2903.5, where quick-closing valves such as clothes washer and dishwasher solenoids are installed, the system needs:

  • a.Water-hammer arrestors✓
  • b.Trap primers
  • c.Vacuum relief valves
  • d.Backwater check valves

The flow velocity is controlled to reduce water hammer, and a water-hammer arrestor conforming to ASSE 1010 is installed where quick-closing valves are used.IRC §P2903.5

Water Supply and Distribution

An outdoor hose bibb on a house must be protected against backflow, under IRC §P2902.4.3, by:

  • a.A vacuum breaker✓
  • b.A gate valve
  • c.A pressure gauge
  • d.A strainer

Sillcocks, hose bibbs and wall hydrants are protected by an atmospheric-type or pressure-type vacuum breaker or a permanently attached hose connection vacuum breaker.IRC §P2902.4.3

Water Supply and Distribution

A lawn irrigation system connected to the house water supply has a fertiliser injector. Under IRC §P2902.5.3, the potable supply must be protected by:

  • a.A reduced pressure principle backflow prevention assembly✓
  • b.A single swing check valve at the water meter
  • c.An atmospheric vacuum breaker at the lowest sprinkler head
  • d.A hose connection vacuum breaker at the timer

Irrigation systems are protected by an atmospheric vacuum breaker, pressure vacuum breaker or reduced pressure assembly, but where chemicals are introduced only a reduced pressure principle assembly is permitted.IRC §P2902.5.3

Water Supply and Distribution

Under IRC §P2902.3.1, the most reliable backflow protection for a faucet outlet is an air gap, which is measured:

  • a.Vertically from the lowest end of the outlet to the flood level rim✓
  • b.Vertically from the floor to the lowest end of the outlet
  • c.Horizontally from the faucet handle to the far edge of the fixture rim
  • d.Horizontally from the supply stop to the trap of the fixture

An air gap is the unobstructed vertical distance through free air between the lowest opening of the water outlet and the flood level rim of the fixture or receptor.IRC §P2902.3.1

Water Supply and Distribution

A cross-connection is best described as:

  • a.A valve that divides hot water between two bathrooms
  • b.A link between the potable water supply and a source of contamination✓
  • c.A fitting that joins two drain pipes at a right angle
  • d.A strap that holds a hot and a cold water pipe to the same floor joist

A cross-connection is any physical connection or arrangement between a potable water system and a source of non-potable liquid, gas or solid through which backflow could occur.IRC §P2902.1; §R202

Water Supply and Distribution

Under IRC §P2903.10, a hose bibb exposed to freezing that is not a frost-proof type must have:

  • a.A trap primer in the supply line
  • b.A cleanout plug at the outlet
  • c.A pressure-reducing valve at the wall outlet
  • d.A stop-and-waste valve inside the building✓

Hose bibbs subject to freezing have a stop-and-waste type valve inside the building so they can be shut off and drained in cold weather; frost-proof hose bibbs whose stem reaches into the heated space are excepted.IRC §P2903.10

Water Supply and Distribution

Under IRC §P2906.4, water service pipe must have a working pressure rating at 73°F of at least:

  • a.800 psi
  • b.160 psi✓
  • c.16 psi
  • d.500 psi

Water service pipe and tubing has a minimum working pressure rating of 160 psi at 73°F; where the supply pressure is higher, the pipe is rated for that pressure.IRC §P2906.4

Water Supply and Distribution

Under IRC §P2906.5, hot and cold water distribution pipe inside a house must be rated for at least:

  • a.25 psi at 212°F
  • b.500 psi at 400°F
  • c.100 psi at 180°F✓
  • d.10 psi at 100°F

Water distribution pipe and tubing has a minimum pressure rating of 100 psi at 180°F, so that it can carry hot water at line pressure.IRC §P2906.5

Water Supply and Distribution

A water service is laid in the same trench as a building sewer made of a material not approved for use inside the building. Under IRC §P2906.4.1, the water pipe must be separated from the sewer:

  • a.By 5 feet horizontally, or be at least 12 inches above the sewer on a ledge✓
  • b.By 1 inch horizontally, or be wrapped in plastic tape for its full length
  • c.By 50 feet horizontally, with no alternative arrangement permitted
  • d.By being laid directly underneath the sewer in the same bedding

The water service is separated by 5 feet of undisturbed or compacted earth, or laid on a shelf with its bottom at least 12 inches above the top of the sewer. No separation is needed where the sewer is of materials listed for use within a building.IRC §P2906.4.1

Water Supply and Distribution

Under IRC §P2906.2, solder and flux used on potable water piping must have a lead content of not more than:

  • a.8 percent
  • b.50 percent
  • c.0.2 percent✓
  • d.25 percent

Solders and fluxes contain not more than 0.2 percent lead; pipes and fittings are limited to a weighted average of 0.25 percent lead on wetted surfaces.IRC §P2906.2

Water Supply and Distribution

Under IRC §P2906.9.1, when PVC water pipe is joined by solvent cement, the joint surfaces are first treated with:

  • a.A purple primer✓
  • b.A pipe-thread compound
  • c.A soldering flux
  • d.A petroleum grease

PVC joints are cleaned, primed with a purple primer conforming to ASTM F656 and cemented while the primer is still wet.IRC §P2906.9.1

Water Supply and Distribution

A soldered joint on copper water tube is made, under IRC §P2906.14, by cutting the tube square, reaming it, cleaning the surfaces and then:

  • a.Applying flux and soldering with a lead-free solder✓
  • b.Applying primer and solvent cement to both surfaces
  • c.Heating the tube until it is cherry red
  • d.Wrapping the tube with thread seal tape

Joint surfaces are cleaned bright, a flux conforming to ASTM B813 is applied and the joint is soldered with a solder conforming to ASTM B32; for potable water the solder and flux are lead free.IRC §P2906.14

Water Supply and Distribution

Under the IRC, a water pipe may be bent on site only where:

  • a.The bend replaces a fitting in a concealed location
  • b.The bend is made with a torch, heating the pipe until it softens enough to be shaped around a form by hand
  • c.The bend is made without kinking or flattening, within the manufacturer's minimum radius✓
  • d.The pipe is rigid CPVC or PVC of any diameter

Flexible tubing such as PEX and annealed copper may be bent to the manufacturer's minimum radius; kinked, buckled or deformed pipe is not used.IRC §P2906.1; §P2608

Water Supply and Distribution

Under IRC §P2903.2, the maximum flow rate for a lavatory faucet in a house is:

  • a.2.2 gpm at 60 psi✓
  • b.0.2 gpm at 60 psi
  • c.9.5 gpm at 60 psi
  • d.5.0 gpm at 60 psi

Table P2903.2 limits lavatory and sink faucets to 2.2 gpm at 60 psi, shower heads to 2.5 gpm at 80 psi and water closets to 1.6 gallons per flush.IRC Table P2903.2

Water Supply and Distribution

Under IRC Table P2903.2, a new water closet in a house may use no more than:

  • a.1.6 gallons per flush✓
  • b.5.0 gallons per flush
  • c.0.2 gallons per flush
  • d.3.5 gallons per flush

Water closets are limited to 1.6 gallons per flushing cycle. Older 3.5-gallon and 5-gallon closets may not be installed as new fixtures.IRC Table P2903.2

Water Supply and Distribution

Under IRC Table P2903.2, the maximum flow rate of a shower head is:

  • a.6.0 gpm at 80 psi
  • b.2.5 gpm at 80 psi✓
  • c.8.5 gpm at 80 psi
  • d.0.5 gpm at 80 psi

Shower heads are limited to 2.5 gpm at 80 psi.IRC Table P2903.2

Water Supply and Distribution

Under IRC §P2903.8, in a parallel (manifold) water distribution system, each fixture is supplied by:

  • a.A branch from the nearest fixture's supply
  • b.A line that returns to the water heater
  • c.Its own distribution line from the manifold✓
  • d.A single loop shared with every other fixture

A parallel system runs an individual distribution line from a manifold to each fixture, usually in PEX; the manifold is sized from Table P2903.8.1.IRC §P2903.8

Water Supply and Distribution

Under IRC §P2903.8.5, each fixture valve on a manifold that is located away from the fixture it serves must be:

  • a.Painted red for hot and blue for cold
  • b.Removed after the final inspection
  • c.Identified with the fixture it supplies✓
  • d.Sealed so that it cannot be closed

Where individual fixture shutoff valves are at the manifold, each is identified by the fixture it supplies, so that the right line can be closed quickly.IRC §P2903.8.5

Water Supply and Distribution

Non-potable water piping in a house, such as a rainwater line to water closets, must under IRC §P2901.2 be:

  • a.Run in the same sleeve as the potable water pipe
  • b.Identified by color marking or tags as non-potable✓
  • c.Made of the same pipe with no marking of any kind
  • d.Connected to the potable system by a gate valve

Where non-potable water systems are installed, the piping is identified by color marking, metal tags or tape, so that nobody later connects a drinking outlet to it.IRC §P2901.2

Water Supply and Distribution

Under IRC §P2904, a dwelling fire sprinkler system that is combined with the cold water distribution piping is called:

  • a.A deluge system
  • b.A dry-pipe system
  • c.A standpipe system
  • d.A multipurpose system✓

A multipurpose fire sprinkler system supplies both the sprinklers and the plumbing fixtures from the same piping. In Texas its installer holds the multipurpose residential fire protection sprinkler specialist endorsement.IRC §P2904.1; Tex. Occ. Code §1301.3565

Water Supply and Distribution

A reverse osmosis drinking water unit is installed under a kitchen sink. Under IRC §P2909.2, its waste line must discharge:

  • a.Directly into the trap arm of the nearest lavatory
  • b.Directly into the vent stack above the roof line
  • c.Through an air gap or an approved air-gap device✓
  • d.Through a hose pushed down into the floor drain

The discharge from a reverse osmosis drinking water treatment unit enters the drainage system through an air gap or an air-gap device, so that sewage cannot be drawn back into the unit.IRC §P2909.2

Water Supply and Distribution

Under IRC §P2603.5, where the frost line requires it, an exterior water service pipe must be buried at least 12 inches deep and at least:

  • a.60 inches below the frost line
  • b.Level with the frost line
  • c.6 inches below the frost line✓
  • d.6 inches above the frost line

Exterior water supply piping is installed not less than 6 inches below the frost line and not less than 12 inches below grade.IRC §P2603.5

Water Supply and Distribution

A plumber joins copper tube to galvanized steel pipe in a house. To prevent galvanic corrosion, the IRC requires the joint to be made with:

  • a.A rubber hose with two worm clamps
  • b.A dielectric fitting or a brass converter fitting✓
  • c.A lead-wiped joint made on site
  • d.A solvent-cemented plastic coupling rated for hot water

Joints between copper and galvanized steel are made with a copper alloy (brass) fitting or a dielectric fitting, which separates the dissimilar metals.IRC §P2906.17.1

Water Supply and Distribution

Under IRC §P2905, a hot water recirculation pump in a house must:

  • a.Be installed on the gas supply line
  • b.Discharge into the cold water service
  • c.Run at all times to keep the whole loop at tank temperature
  • d.Be controlled so that it does not run continuously✓

IRC P2905.1 requires heated water circulation systems to meet the energy provisions in N1103.5.1, which require pump controls that start the pump on demand for hot water and turn it off when the loop is up to temperature. A pump that runs continuously without control does not comply.IRC §P2905.1; §N1103.5.1

Water Supply and Distribution

Under IRC §P2902.6, a backflow prevention assembly on a house irrigation line must be installed where it is:

  • a.Sealed inside a wall with no access panel
  • b.Accessible for testing, maintenance and repair✓
  • c.Buried in the yard without a box or cover
  • d.Submerged in a pit that holds standing water

Backflow preventers are located where they can be reached for inspection, testing and repair, and are protected from freezing and from submersion, which could let contamination enter through the relief port.IRC §P2902.6