California Civil Engineer: Seismic Principles — All Questions

300 questions

Seismic Analysis Procedures

A flexible wood roof diaphragm spans L = 96 ft between end shear walls and is 48 ft deep. The uniform seismic load on the diaphragm is 500 lb/ft. What is the maximum unit shear in the diaphragm at the end walls?

  • a.250 lb/ft
  • b.400 lb/ft
  • c.500 lb/ft✓
  • d.1,000 lb/ft

The diaphragm acts as a simple beam: end reaction V = wL/2 = 500 x 96/2 = 24,000 lb. Unit shear v = V/b = 24,000/48 = 500 lb/ft. Using the full load wL in place of the reaction doubles the answer, and dividing by the span instead of the depth mixes up the two plan dimensions.

Seismic Analysis Procedures

A flexible diaphragm spans 120 ft between shear walls, is 60 ft deep, and carries a uniform seismic load of 400 lb/ft. What is the maximum chord force?

  • a.6,000 lb
  • b.12,000 lb✓
  • c.24,000 lb
  • d.48,000 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 400 x 120^2/8 = 720,000 lb-ft; T = C = M/b = 720,000/60 = 12,000 lb at midspan. The value 24,000 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 100 ft between shear walls, is 40 ft deep, and carries a uniform seismic load of 550 lb/ft. What is the maximum chord force?

  • a.6,875 lb
  • b.8,594 lb
  • c.11,458 lb
  • d.17,188 lb✓

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 550 x 100^2/8 = 687,500 lb-ft; T = C = M/b = 687,500/40 = 17,188 lb at midspan. The value 27,500 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 150 ft between shear walls, is 75 ft deep, and carries a uniform seismic load of 800 lb/ft. What is the maximum chord force?

  • a.15,000 lb
  • b.20,000 lb
  • c.30,000 lb✓
  • d.60,000 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 800 x 150^2/8 = 2,250,000 lb-ft; T = C = M/b = 2,250,000/75 = 30,000 lb at midspan. The value 60,000 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A flexible diaphragm spans 64 ft between shear walls, is 32 ft deep, and carries a uniform seismic load of 350 lb/ft. What is the maximum chord force?

  • a.2,800 lb
  • b.5,600 lb✓
  • c.11,200 lb
  • d.22,400 lb

The chords resist the diaphragm bending moment as a tension-compression couple: M = wL^2/8 = 350 x 64^2/8 = 179,200 lb-ft; T = C = M/b = 179,200/32 = 5,600 lb at midspan. The value 11,200 lb is the end reaction (a shear, not a chord force), and dividing the moment by the span rather than the depth uses the wrong lever arm.

Seismic Analysis Procedures

A roof diaphragm delivers 24,000 lb to a wall line that is 60 ft long. The only shear wall on that line is 20 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.16,000 lb✓
  • b.20,000 lb
  • c.24,000 lb
  • d.32,000 lb

Diaphragm unit shear along the line: 24,000/60 = 400 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 400 x (60 - 20) = 16,000 lb. Check from the wall side: net shear in the wall (1200 - 400 = 800 lb/ft) x 20 ft gives the same force. The full line load 24,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 18,000 lb to a wall line that is 40 ft long. The only shear wall on that line is 16 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.10,800 lb✓
  • b.13,500 lb
  • c.16,200 lb
  • d.18,000 lb

Diaphragm unit shear along the line: 18,000/40 = 450 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 450 x (40 - 16) = 10,800 lb. Check from the wall side: net shear in the wall (1125 - 450 = 675 lb/ft) x 16 ft gives the same force. The full line load 18,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 30,000 lb to a wall line that is 100 ft long. The only shear wall on that line is 40 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.12,000 lb
  • b.15,000 lb
  • c.18,000 lb✓
  • d.30,000 lb

Diaphragm unit shear along the line: 30,000/100 = 300 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 300 x (100 - 40) = 18,000 lb. Check from the wall side: net shear in the wall (750 - 300 = 450 lb/ft) x 40 ft gives the same force. The full line load 30,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A roof diaphragm delivers 12,000 lb to a wall line that is 48 ft long. The only shear wall on that line is 12 ft long and sits at one end; a collector (drag strut) runs along the remaining length. What is the maximum collector force?

  • a.9,000 lb✓
  • b.11,250 lb
  • c.12,000 lb
  • d.13,500 lb

Diaphragm unit shear along the line: 12,000/48 = 250 lb/ft. The collector accumulates this over the length without wall, peaking where it meets the wall: 250 x (48 - 12) = 9,000 lb. Check from the wall side: net shear in the wall (1000 - 250 = 750 lb/ft) x 12 ft gives the same force. The full line load 12,000 lb would apply only if the wall had no length directly loaded by the diaphragm.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 100 kips to 3 parallel shear walls with relative rigidities A = 2, B = 3, C = 5. What shear does wall C resist?

  • a.30.0 kips
  • b.33.3 kips
  • c.40.0 kips
  • d.50.0 kips✓

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_C = V x R/sum(R) = 100 x 5/10 = 50.0 kips. An equal split (33.3 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 240 kips to 3 parallel shear walls with relative rigidities A = 1, B = 1, C = 4. What shear does wall A resist?

  • a.30.0 kips
  • b.40.0 kips✓
  • c.80.0 kips
  • d.200.0 kips

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_A = V x R/sum(R) = 240 x 1/6 = 40.0 kips. An equal split (80.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 180 kips to 2 parallel shear walls with relative rigidities A = 3, B = 6. What shear does wall A resist?

  • a.60.0 kips✓
  • b.78.0 kips
  • c.90.0 kips
  • d.120.0 kips

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_A = V x R/sum(R) = 180 x 3/9 = 60.0 kips. An equal split (90.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

A rigid diaphragm with no torsion delivers a story shear of 150 kips to 3 parallel shear walls with relative rigidities A = 4, B = 2.5, C = 3.5. What shear does wall B resist?

  • a.22.5 kips
  • b.25.1 kips
  • c.30.0 kips
  • d.37.5 kips✓

With a rigid diaphragm, walls displace equally and share force in proportion to rigidity: V_B = V x R/sum(R) = 150 x 2.5/10 = 37.5 kips. An equal split (50.0 kips each) or a tributary-width split would be the logic for a flexible diaphragm, not a rigid one.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 4 at x = 0 ft; R = 2 at x = 60 ft. Where is the center of rigidity in the x-direction?

  • a.10.0 ft
  • b.15.0 ft
  • c.20.0 ft✓
  • d.30.0 ft

x_cr = sum(R x)/sum(R) = (4 x 0 + 2 x 60)/6 = 20.0 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (30 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 40.0 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 3 at x = 0 ft; R = 3 at x = 40 ft; R = 6 at x = 100 ft. Where is the center of rigidity in the x-direction?

  • a.60.0 ft✓
  • b.75.0 ft
  • c.90.0 ft
  • d.120.0 ft

x_cr = sum(R x)/sum(R) = (3 x 0 + 3 x 40 + 6 x 100)/12 = 60.0 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (50 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 40.0 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 5 at x = 0 ft; R = 1 at x = 80 ft. Where is the center of rigidity in the x-direction?

  • a.6.7 ft
  • b.10.0 ft
  • c.13.3 ft✓
  • d.40.0 ft

x_cr = sum(R x)/sum(R) = (5 x 0 + 1 x 80)/6 = 13.3 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (40 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 66.7 ft.

Seismic Analysis Procedures

North-south shear walls in a rigid-diaphragm building are located (measured from the west edge) as follows: R = 2 at x = 0 ft; R = 4 at x = 30 ft; R = 2 at x = 90 ft. Where is the center of rigidity in the x-direction?

  • a.37.5 ft✓
  • b.40.0 ft
  • c.45.0 ft
  • d.52.5 ft

x_cr = sum(R x)/sum(R) = (2 x 0 + 4 x 30 + 2 x 90)/8 = 37.5 ft from the west edge. The center of rigidity is pulled toward the stiffer walls; the geometric midpoint (45 ft) would be correct only for a symmetric layout, and measuring from the wrong edge gives 52.5 ft.

Seismic Analysis Procedures

A story shear of 200 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 8 ft, and the building dimension perpendicular to the force is 100 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.1,000 kip-ft
  • b.1,300 kip-ft
  • c.1,600 kip-ft
  • d.2,600 kip-ft✓

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 200 x 8 = 1,600 kip-ft; accidental torsion Mta = V x 0.05L = 200 x 5 = 1,000 kip-ft. Total = 2,600 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

A story shear of 150 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 0 ft, and the building dimension perpendicular to the force is 80 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.300 kip-ft
  • b.600 kip-ft✓
  • c.720 kip-ft
  • d.1,200 kip-ft

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 150 x 0 = 0 kip-ft; accidental torsion Mta = V x 0.05L = 150 x 4 = 600 kip-ft. Total = 600 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

A story shear of 320 kips acts on a rigid diaphragm. The calculated distance between the center of mass and center of rigidity, perpendicular to the force, is 12 ft, and the building dimension perpendicular to the force is 160 ft. What design torsional moment results when accidental torsion adds to the inherent torsion?

  • a.2,560 kip-ft
  • b.3,200 kip-ft
  • c.3,840 kip-ft
  • d.6,400 kip-ft✓

ASCE 7-16 Sections 12.8.4.1 and 12.8.4.2: inherent torsion Mt = V x e = 320 x 12 = 3,840 kip-ft; accidental torsion Mta = V x 0.05L = 320 x 8 = 2,560 kip-ft. Total = 6,400 kip-ft. The 5% is taken on the dimension perpendicular to the applied force; using 10% or ignoring the accidental part are the usual mistakes.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 10 ft high and 20 ft long; wall B is 10 ft high and 10 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.22%
  • b.67%
  • c.78%✓
  • d.89%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.50, R = 0.500. Wall B: h/d = 1.00, R = 0.143. Share to A = 0.500/(0.500 + 0.143) = 78%. A split by length alone (67%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 12 ft high and 24 ft long; wall B is 12 ft high and 8 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.10%
  • b.75%
  • c.90%✓
  • d.96%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.50, R = 0.500. Wall B: h/d = 1.50, R = 0.056. Share to A = 0.500/(0.500 + 0.056) = 90%. A split by length alone (75%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 14 ft high and 14 ft long; wall B is 14 ft high and 28 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.11%
  • b.22%✓
  • c.33%
  • d.78%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 1.00, R = 0.143. Wall B: h/d = 0.50, R = 0.500. Share to A = 0.143/(0.143 + 0.500) = 22%. A split by length alone (33%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

Two cantilever concrete shear walls of equal thickness and material share load through a rigid diaphragm. Wall A is 10 ft high and 30 ft long; wall B is 10 ft high and 15 ft long. Using deflection proportional to 4(h/d)^3 + 3(h/d), what percentage of the shear goes to wall A?

  • a.74%✓
  • b.89%
  • c.92%
  • d.110%

Relative rigidity R = 1/[4(h/d)^3 + 3(h/d)]. Wall A: h/d = 0.33, R = 0.871. Wall B: h/d = 0.67, R = 0.314. Share to A = 0.871/(0.871 + 0.314) = 74%. A split by length alone (67%) ignores that both flexural and shear deformation depend nonlinearly on the aspect ratio.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 60 ft and 40 ft, and the uniform seismic load is 500 lb/ft. What load goes to the interior wall line?

  • a.10,000 lb
  • b.15,000 lb
  • c.16,667 lb
  • d.25,000 lb✓

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 500 x (60/2 + 40/2) = 25,000 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 80 ft and 80 ft, and the uniform seismic load is 360 lb/ft. What load goes to the interior wall line?

  • a.14,400 lb
  • b.19,200 lb
  • c.28,800 lb✓
  • d.36,000 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 360 x (80/2 + 80/2) = 28,800 lb. An equal three-way split (19,200 lb) or a continuous-beam interior reaction of 1.25wL = 36,000 lb (5/8 wL from each span) assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 50 ft and 100 ft, and the uniform seismic load is 420 lb/ft. What load goes to the interior wall line?

  • a.31,500 lb✓
  • b.39,375 lb
  • c.47,250 lb
  • d.63,000 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 420 x (50/2 + 100/2) = 31,500 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A flexible diaphragm is supported by three parallel shear wall lines: two end walls and one interior wall. The spans are 30 ft and 70 ft, and the uniform seismic load is 600 lb/ft. What load goes to the interior wall line?

  • a.20,000 lb
  • b.21,000 lb
  • c.30,000 lb✓
  • d.37,500 lb

A flexible diaphragm distributes load by tributary width, as two simple spans: the interior line receives half of each adjacent span: 600 x (30/2 + 70/2) = 30,000 lb. An equal three-way split or a continuous-beam (5/8) reaction assumes diaphragm stiffness that a flexible diaphragm does not have.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 1,200 lb per foot of wall. Wall anchors connect to roof framing members spaced 8 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.9,600 lb✓
  • b.12,000 lb
  • c.14,400 lb
  • d.19,200 lb

Each anchor collects the wall force over its tributary width: 1,200 lb/ft x 8 ft = 9,600 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 1,500 lb per foot of wall. Wall anchors connect to roof framing members spaced 4 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.1,500 lb
  • b.3,000 lb
  • c.4,800 lb
  • d.6,000 lb✓

Each anchor collects the wall force over its tributary width: 1,500 lb/ft x 4 ft = 6,000 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A tilt-up wall panel requires a design anchorage force of 980 lb per foot of wall. Wall anchors connect to roof framing members spaced 6 ft on center. What force must each anchor (and the tie it connects to) be designed for?

  • a.980 lb
  • b.5,880 lb✓
  • c.8,820 lb
  • d.11,760 lb

Each anchor collects the wall force over its tributary width: 980 lb/ft x 6 ft = 5,880 lb. That force must then be carried by continuous ties or struts into the diaphragm (ASCE 7-16 Section 12.11.2.2.1), typically through a subdiaphragm. Halving the tributary width or using the per-foot value understates the connection demand.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,200 lb/ft into the main diaphragm. The subdiaphragm is 24 ft long (parallel to the wall, between continuous crossties) and 16 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.600 lb/ft
  • b.900 lb/ft✓
  • c.1,260 lb/ft
  • d.1,800 lb/ft

The subdiaphragm spans 24 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,200 x 24/2 = 14,400 lb, resisted over the 16-ft depth: v = 14,400/16 = 900 lb/ft. Its length-to-depth ratio of 1.50 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,000 lb/ft into the main diaphragm. The subdiaphragm is 40 ft long (parallel to the wall, between continuous crossties) and 20 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.1,000 lb/ft✓
  • b.1,250 lb/ft
  • c.1,400 lb/ft
  • d.2,000 lb/ft

The subdiaphragm spans 40 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,000 x 40/2 = 20,000 lb, resisted over the 20-ft depth: v = 20,000/20 = 1,000 lb/ft. Its length-to-depth ratio of 2.00 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A subdiaphragm transfers wall anchorage forces of 1,400 lb/ft into the main diaphragm. The subdiaphragm is 30 ft long (parallel to the wall, between continuous crossties) and 15 ft deep. What is the maximum unit shear in the subdiaphragm?

  • a.1,400 lb/ft✓
  • b.1,750 lb/ft
  • c.1,960 lb/ft
  • d.2,800 lb/ft

The subdiaphragm spans 30 ft between crossties as a simple beam loaded by the anchorage force: reaction = 1,400 x 30/2 = 21,000 lb, resisted over the 15-ft depth: v = 21,000/15 = 1,400 lb/ft. Its length-to-depth ratio of 2.00 is within the 2.5:1 limit of ASCE 7-16 Section 12.11.2.2.1. Using the total load instead of the reaction doubles the shear.

Seismic Analysis Procedures

A torsional moment of 2,000 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 4 lies 30 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 9,000. What torsional shear does this wall receive?

  • a.6.7 kips
  • b.26.7 kips✓
  • c.66.7 kips
  • d.80.0 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 2,000 x 4 x 30 / 9,000 = 26.7 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (66.7 kips) assumes that single wall resists all of the torsion.

Seismic Analysis Procedures

A torsional moment of 3,600 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 2 lies 50 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 14,000. What torsional shear does this wall receive?

  • a.12.9 kips
  • b.25.7 kips✓
  • c.72.0 kips
  • d.128.6 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 3,600 x 2 x 50 / 14,000 = 25.7 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (72.0 kips) assumes that single wall resists all of the torsion.

Seismic Analysis Procedures

A torsional moment of 1,500 kip-ft acts on a rigid diaphragm. A wall with relative rigidity R = 5 lies 20 ft from the center of rigidity, and the polar term sum(R d^2) for all walls is 6,400. What torsional shear does this wall receive?

  • a.4.7 kips
  • b.23.4 kips✓
  • c.46.9 kips
  • d.75.0 kips

Torsional shear V_t = T x R x d / sum(R d^2) = 1,500 x 5 x 20 / 6,400 = 23.4 kips. This adds to (or, where it would subtract, is not used to reduce) the wall's direct shear. Dividing the moment by the wall's distance alone (75.0 kips) assumes that single wall resists all of the torsion.

Seismic Analysis Procedures

At one level of a torsionally irregular building in SDC D, the displacements at the two ends of the rigid diaphragm are 1.5 in. and 0.7 in. What accidental torsion amplification factor Ax applies?

  • a.1.00
  • b.1.14
  • c.1.29✓
  • d.1.86

ASCE 7-16 Eq. 12.8-14: Ax = [delta_max/(1.2 delta_avg)]^2 with delta_avg = (1.5 + 0.7)/2 = 1.10 in. Ax = [1.5/(1.2 x 1.10)]^2 = 1.29, bounded between 1.0 and 3.0. Forgetting to square the ratio or dropping the 1.2 are the common errors.

Seismic Analysis Procedures

At one level of a torsionally irregular building in SDC D, the displacements at the two ends of the rigid diaphragm are 2.0 in. and 1.0 in. What accidental torsion amplification factor Ax applies?

  • a.1.23✓
  • b.1.54
  • c.1.78
  • d.3.00

ASCE 7-16 Eq. 12.8-14: Ax = [delta_max/(1.2 delta_avg)]^2 with delta_avg = (2.0 + 1.0)/2 = 1.50 in. Ax = [2.0/(1.2 x 1.50)]^2 = 1.23, bounded between 1.0 and 3.0. Forgetting to square the ratio or dropping the 1.2 are the common errors.

Seismic Analysis Procedures

A one-story steel frame has 4 identical columns, each with I = 800 in.^4, E = 29,000 ksi and height 14 ft. The columns are fixed at the base and fixed against rotation at the top by a rigid girder. What is the lateral stiffness of the story?

  • a.58.7 kips/in.
  • b.157.4 kips/in.
  • c.187.9 kips/in.
  • d.234.9 kips/in.✓

Each column contributes k = 12EI/h^3 (fixed-fixed): 12 x 29,000 x 800/(168)^3 = 58.7 kips/in. For 4 columns in parallel, k = 234.9 kips/in. The coefficient 3 would apply if the top were pinned, a fourfold difference in stiffness.

Seismic Analysis Procedures

A one-story steel frame has 6 identical columns, each with I = 500 in.^4, E = 29,000 ksi and height 12 ft. The columns are fixed at the base and pinned at the top. What is the lateral stiffness of the story?

  • a.14.6 kips/in.
  • b.87.4 kips/in.✓
  • c.125.9 kips/in.
  • d.349.6 kips/in.

Each column contributes k = 3EI/h^3 (cantilever, fixed-pinned): 3 x 29,000 x 500/(144)^3 = 14.6 kips/in. For 6 columns in parallel, k = 87.4 kips/in. The coefficient 12 would apply if the top were restrained against rotation, a fourfold difference in stiffness.

Seismic Analysis Procedures

What is meant by a continuous load path in seismic design?

  • a.Inertial forces can be traced through connected elements from their origin to the foundation✓
  • b.The same lateral system type is used in both of the principal plan directions
  • c.Every wall in the building is continuous without openings from foundation to roof
  • d.Gravity loads are carried by the shortest possible route from the roof framing down to the footings

ASCE 7-16 Section 12.1.3 requires a continuous load path with adequate strength and stiffness to transfer all forces from the point of application to the final point of resistance: diaphragm to collectors to walls or frames to foundation to soil. Any missing link defeats the whole system.

Seismic Analysis Procedures

In a horizontal diaphragm analogous to a deep beam, which elements resist the bending moment?

  • a.The sheathing at midspan
  • b.The hold-downs at the wall ends
  • c.The collectors at the shear walls
  • d.The chords at the diaphragm edges✓

Diaphragm sheathing acts like a beam web carrying shear, while chords (edge members perpendicular to the load, such as top plates, ledgers or wall reinforcing) act like flanges carrying tension and compression. Collectors transfer shear to the vertical elements; hold-downs resist shear wall overturning.

Seismic Analysis Procedures

What is the function of a collector (drag strut)?

  • a.To brace a wall panel against out-of-plane wind and seismic load
  • b.To resist overturning uplift at the end posts of a shear wall
  • c.To gather diaphragm shear and deliver it to the vertical lateral elements✓
  • d.To resist diaphragm bending by acting as the tension or compression flange

A collector runs parallel to the applied force and transfers diaphragm shear from areas with no wall or frame into the vertical elements (ASCE 7-16 Section 12.10.2). Chords resist diaphragm flexure, hold-downs resist wall overturning, and wall anchors handle out-of-plane forces.

Seismic Analysis Procedures

How does a flexible diaphragm distribute lateral force to the vertical resisting elements?

  • a.Entirely to the element nearest the center of mass
  • b.Equally to each element regardless of location
  • c.By tributary area, like simple beams between supports✓
  • d.By relative rigidity of the vertical elements

A flexible diaphragm cannot enforce equal displacements, so each wall line receives the load tributary to it and no torsion is transmitted. Rigidity-based distribution, including torsion, is the rigid diaphragm model.

Seismic Analysis Procedures

A rigid-diaphragm building's center of mass does not coincide with its center of rigidity. What results under lateral load?

  • a.Torsion about the center of rigidity, adding shear to some walls✓
  • b.Reduced base shear, because eccentricity lengthens the period
  • c.No effect, because a rigid diaphragm cannot rotate in plan
  • d.Vertical uplift on all walls equal to the eccentricity times V

The inertial force acts through the center of mass while resistance acts through the center of rigidity; the offset creates an inherent torsional moment Mt = V x e (ASCE 7-16 Section 12.8.4.1), which the walls resist in proportion to their rigidity and distance from the center of rigidity.

Seismic Analysis Procedures

Accidental torsion is represented by displacing the center of mass each way by what distance?

  • a.5% of the building dimension perpendicular to the applied force✓
  • b.5% of the building dimension parallel to the direction of applied force
  • c.10% of the building height measured from the base
  • d.15% of the distance between the two outermost shear walls

ASCE 7-16 Section 12.8.4.2 assumes a displacement of the center of mass equal to 5% of the dimension of the structure perpendicular to the direction of the applied forces. It covers uncertainties in mass and stiffness distribution and torsional ground motion.

Seismic Analysis Procedures

In a torsional analysis, the torsional shear in a wall acts opposite to its direct shear. How is the wall designed in common practice?

  • a.For the torsional shear alone, ignoring the direct shear completely
  • b.For the direct shear minus the full value of the torsional shear
  • c.For the direct shear alone, without taking the torsional reduction✓
  • d.For zero shear, because the two components cancel one another

Because accidental eccentricity is taken in both directions, each wall is designed for the most severe case; where torsion would reduce the direct shear, the reduction is neglected so the wall is not under-designed if the actual eccentricity is on the other side.

Seismic Analysis Procedures

In Seismic Design Category D, when must orthogonal (bidirectional) load effects be considered for a column?

  • a.When the column is located anywhere within a building that has a flexible wood structural panel roof diaphragm
  • b.When the column supports only gravity framing in a building that has perimeter shear walls
  • c.When the column is taller than 12 ft, regardless of the framing that it participates in
  • d.When the column is part of two intersecting seismic force-resisting systems and carries significant axial load✓

ASCE 7-16 Section 12.5.4 requires columns or walls forming part of two or more intersecting systems with axial load from seismic forces exceeding 20% of design axial strength to be designed for the most critical direction, commonly by the 100% plus 30% combination of Section 12.5.3.1.

Seismic Analysis Procedures

Which combination is the usual way of satisfying the orthogonal combination procedure?

  • a.100% of forces in one direction plus 30% in the perpendicular direction✓
  • b.70% of forces in one direction plus 70% in the perpendicular direction
  • c.50% of forces in one direction plus 50% in the perpendicular direction
  • d.100% of forces in one direction plus 100% in the perpendicular direction

ASCE 7-16 Section 12.5.3.1(a) applies 100% of the forces for one direction plus 30% of the forces for the perpendicular direction, using whichever combination gives the larger effect. Peak responses in two directions are unlikely to coincide, so 100% plus 100% is overly severe.