250 questions

Water Heaters

The terminal of a direct-vent water heater with an input of 60,000 Btu/h must, under IFGC §503.8, be located at least how far from any air opening into the building?

  • a.12 inches✓
  • b.36 inches
  • c.6 feet
  • d.10 feet

Direct-vent terminal clearance from air openings is 6 inches for appliances up to 10,000 Btu/h, 9 inches up to 50,000 Btu/h and 12 inches above 50,000 Btu/h.IFGC §503.8

Water Heaters

A mechanical-draft (power vent) water heater terminates through a side wall. Under IFGC §503.8, the terminal must be at least how far above any forced-air inlet located within 10 feet?

  • a.30 feet
  • b.15 feet
  • c.3 inches
  • d.3 feet✓

A mechanical draft venting system terminates at least 3 feet above any forced-air inlet within 10 feet, and at least 4 feet below, 4 feet horizontally from or 1 foot above doors, operable windows and gravity inlets.IFGC §503.8

Water Heaters

A condensing (Category IV) gas water heater is vented with plastic pipe. Under IFGC §503.4.1, the plastic pipe and fittings must be:

  • a.Any Schedule 40 drainage pipe that is available at the job site
  • b.Solvent-cemented without primer, so that the joints stay flexible
  • c.Those specified by the appliance manufacturer's installation instructions✓
  • d.Cellular-core pipe, because its wall insulates the flue gases

Plastic vent piping for appliances follows the appliance manufacturer's instructions, including approved materials and primer where required. Cellular-core pipe is commonly excluded by manufacturers.IFGC §503.4.1

Water Heaters

An electric water heater is installed. Besides the plumbing code, IPC §502.1 requires the electrical work to follow:

  • a.NFPA 13D, with a sprinkler head over the heater
  • b.NFPA 70, with a disconnecting means for the heater✓
  • c.NFPA 54, with a sediment trap at the heater
  • d.NFPA 99, with a zone valve box at the heater

Electric water heaters are installed per the manufacturer and the electrical code, NFPA 70, which requires a disconnect within sight or capable of being locked open.IPC §502.1

Water Heaters

A closed water system is created when a backflow preventer is installed on the water service. Under IPC §607.3, the water heater system must then have:

  • a.A device to control thermal expansion, such as an expansion tank✓
  • b.A vacuum breaker on the cold inlet, upstream of the shutoff
  • c.A larger gas supply, to offset the added pressure in the tank
  • d.A second temperature and pressure relief valve on the hot outlet

Where a check valve, backflow preventer or pressure-reducing valve prevents expansion back into the main, a thermal expansion tank or other approved device controls the pressure rise. The relief valve is a safety device, not an expansion control.IPC §607.3

OSHA Construction Safety

A crew is laying a sewer in a trench 6 feet deep. Under 29 CFR 1926.651(c)(2), a ladder or other safe means of egress must be placed so that no worker travels laterally more than:

  • a.5 feet
  • b.25 feet✓
  • c.100 feet
  • d.50 feet

Trench excavations 4 feet or more in depth need a stairway, ladder, ramp or other safe means of egress within 25 feet of lateral travel for each employee.29 CFR 1926.651(c)(2)

OSHA Construction Safety

At what trench depth does 1926.651(c)(2) first require a ladder, stairway or ramp for egress?

  • a.10 feet
  • b.6 feet
  • c.2 feet
  • d.4 feet✓

The egress rule applies to trench excavations that are 4 feet or more in depth. The 5-foot figure belongs to the cave-in protection rule, not the egress rule.29 CFR 1926.651(c)(2)

OSHA Construction Safety

Under 1926.652(a), a protective system against cave-ins is required in every excavation EXCEPT one that is entirely in stable rock, or one that is:

  • a.Less than 20 feet deep and open for no longer than a single working shift
  • b.Less than 8 feet deep and fitted with a ladder at each end of the trench
  • c.Less than 10 feet deep and dug in soil that has been classified by the operator as Type C
  • d.Less than 5 feet deep and examined by a competent person who finds no sign of a potential cave-in✓

Each employee in an excavation is protected by sloping, shoring or shielding unless the excavation is in stable rock or is under 5 feet deep with no indication of a potential cave-in found by a competent person.29 CFR 1926.652(a)(1)

OSHA Construction Safety

Under 1926.652, a protective system for an excavation more than 20 feet deep must be:

  • a.Approved by the plumbing inspector by phone
  • b.Selected by the equipment operator on site
  • c.Built from timber cut on the job site
  • d.Designed by a registered professional engineer✓

Sloping, benching and support systems for excavations greater than 20 feet deep are designed by a registered professional engineer; the appendix tables stop at 20 feet.29 CFR 1926.652(b), (c)

OSHA Construction Safety

Excavated soil is piled beside a trench. Under 1926.651(j)(2), the spoil must be kept back from the edge at least:

  • a.25 feet
  • b.10 feet
  • c.2 feet✓
  • d.6 inches

Excavated or other materials and equipment are kept at least 2 feet from the edge, or held back by retaining devices, so they cannot fall or roll in and so their weight does not load the trench wall.29 CFR 1926.651(j)(2)

OSHA Construction Safety

Who must inspect an excavation, and how often, under 1926.651(k)?

  • a.The project owner, once when the excavation is first opened
  • b.A city inspector, weekly on the day the permit card is signed off
  • c.A competent person, daily before work and after every rainstorm✓
  • d.Any employee, monthly at the regular safety meeting

Daily inspections of excavations, adjacent areas and protective systems are made by a competent person before the start of work, as needed through the shift and after every rainstorm or other hazard-increasing event.29 CFR 1926.651(k)

OSHA Construction Safety

In OSHA's excavation standard, a "competent person" is someone who:

  • a.Holds a master plumber license and has at least ten years of field experience
  • b.Can identify existing and predictable hazards and has authority to take prompt corrective measures✓
  • c.Has completed a four-year engineering degree and is registered with the state as a professional engineer
  • d.Operates the excavator and has been employed by the company the longest

A competent person is capable of identifying existing and predictable hazards and is authorised to take prompt corrective measures to eliminate them. A license or degree does not by itself meet the definition.29 CFR 1926.650(b)

OSHA Construction Safety

Under 1926.651(g), the atmosphere in an excavation deeper than 4 feet must be tested before entry where an oxygen deficiency could reasonably be expected. Oxygen deficiency means less than:

  • a.30.0 percent oxygen
  • b.10.5 percent oxygen
  • c.23.5 percent oxygen
  • d.19.5 percent oxygen✓

Atmospheres with less than 19.5 percent oxygen are oxygen deficient. Normal air is about 20.9 percent, and 23.5 percent is the threshold for oxygen enrichment in other standards.29 CFR 1926.651(g)(1)

OSHA Construction Safety

Under 1926.651(g), workers may not be exposed in an excavation to a flammable gas concentration above:

  • a.75 percent of the lower flammable limit
  • b.50 percent of the lower flammable limit
  • c.20 percent of the lower flammable limit✓
  • d.100 percent of the lower flammable limit

Precautions such as ventilation are taken to prevent exposure to a flammable gas concentration in excess of 20 percent of the lower flammable limit of the gas.29 CFR 1926.651(g)(1)(iii)

OSHA Construction Safety

Before opening an excavation, 1926.651(b) requires the employer to:

  • a.Determine the estimated location of underground utility installations✓
  • b.Remove every tree within 100 feet of the proposed excavation
  • c.Obtain a soil report signed by a registered geologist
  • d.Shut off water service to every building on the block

The estimated location of sewer, telephone, fuel, electric, water and other underground installations is determined before opening an excavation, and utility owners are contacted within established response times.29 CFR 1926.651(b)

OSHA Construction Safety

Plumbers working in a trench beside a public road are exposed to traffic. Under 1926.651(d), they must be provided with and wear:

  • a.Respirators approved for protection against vehicle exhaust gases
  • b.Flotation vests approved by the United States Coast Guard
  • c.Hearing protection rated for at least 30 decibels of noise reduction
  • d.Warning vests or other garments of reflectorized or high-visibility material✓

Employees exposed to public vehicular traffic wear warning vests or other suitable garments marked with or made of reflectorized or high-visibility material.29 CFR 1926.651(d)

OSHA Construction Safety

A walkway crosses over a trench. Under 1926.651(l), guardrails are required on the walkway where it is how far above the lower level?

  • a.15 feet or more
  • b.1 foot or more
  • c.30 feet or more
  • d.6 feet or more✓

Where employees or equipment cross over excavations, walkways are provided, and guardrails are required where walkways are 6 feet or more above lower levels.29 CFR 1926.651(l)

OSHA Construction Safety

OSHA's Appendix B to Subpart P gives the maximum allowable slope for an excavation less than 20 feet deep in Type C soil as:

  • a.1/2 horizontal to 1 vertical (63 degrees)
  • b.1-1/2 horizontal to 1 vertical (34 degrees)✓
  • c.1-1/4 horizontal to 1 vertical (39 degrees)
  • d.3/4 horizontal to 1 vertical (53 degrees)

Type C soil, the least stable, is sloped at 1-1/2 to 1. Type A may be sloped at 3/4 to 1 and Type B at 1 to 1. Vertical sides are allowed only in stable rock.29 CFR 1926 Subpart P, Appendix B

OSHA Construction Safety

Under 29 CFR 1926 Subpart P, Appendix B, the maximum allowable slope for a simple slope excavation in Type B soil 20 feet or less in depth is:

  • a.3 horizontal to 1 vertical (18 degrees)
  • b.1 horizontal to 1 vertical (45 degrees)✓
  • c.2 horizontal to 1 vertical (27 degrees)
  • d.1/4 horizontal to 1 vertical (76 degrees)

Simple slope excavations in Type B soil 20 feet or less deep have a maximum allowable slope of 1:1, or 45 degrees. Type A soil allows 3/4:1 and Type C soil requires 1 1/2:1.29 CFR 1926 Subpart P, Appendix B

OSHA Construction Safety

A trench shield (trench box) is used in a sewer trench. Under 1926.652(g)(2), earth may be excavated below the bottom of the shield to a depth of no more than:

  • a.6 feet, if the shield is designed for the full trench depth and the soil shows no loss
  • b.10 feet, where the trench is dug in soil classified as Type A
  • c.2 feet, if the shield is designed for the full trench depth and the soil shows no loss✓
  • d.Any depth, where workers stay inside the shield at all times

Excavation up to 2 feet below the bottom of a shield is permitted only if the shield is designed to resist forces for the full depth and there are no indications of soil loss from behind or below the shield.29 CFR 1926.652(g)(2)

OSHA Construction Safety

Under 1926.451(b)(2), a scaffold platform and walkway must generally be at least:

  • a.60 inches wide
  • b.18 inches wide✓
  • c.6 inches wide
  • d.36 inches wide

Each scaffold platform and walkway is at least 18 inches wide; ladder jack, top plate bracket, roof bracket and pump jack scaffolds may be 12 inches.29 CFR 1926.451(b)(2)

OSHA Construction Safety

Under 1926.451(g)(1), fall protection is required for each employee on a scaffold that is more than how far above a lower level?

  • a.10 feet✓
  • b.20 feet
  • c.30 feet
  • d.4 feet

Each employee on a scaffold more than 10 feet above a lower level is protected from falling by guardrails, a personal fall arrest system or both, depending on the scaffold type.29 CFR 1926.451(g)(1)

OSHA Construction Safety

A supported scaffold is taller than four times its minimum base width. Under 1926.451(c)(1), it must be:

  • a.Loaded with sandbags on the top platform to steady it
  • b.Used only by employees who weigh less than 200 pounds
  • c.Restrained from tipping by guying, tying, bracing or equivalent means✓
  • d.Taken down and replaced with ladders before work continues

Supported scaffolds with a height-to-base-width ratio of more than 4 to 1 are restrained from tipping by guys, ties, braces or equivalent means.29 CFR 1926.451(c)(1)

OSHA Construction Safety

Under 1926.451(e)(1), a ladder, stair tower or other safe access is required when a scaffold platform is more than how far above or below the point of access?

  • a.10 feet
  • b.6 inches
  • c.2 feet✓
  • d.6 feet

When scaffold platforms are more than 2 feet above or below a point of access, portable ladders, hook-on ladders, stair towers or similar means are used; cross braces are not used as access.29 CFR 1926.451(e)(1)

OSHA Construction Safety

Under 1926.451(f)(3), scaffolds must be inspected for visible defects by a competent person:

  • a.Only when an employee files a written complaint with the employer
  • b.Once a year, on the anniversary of the date the scaffold was purchased or last recertified
  • c.Once, at the time the scaffold is first erected on the project
  • d.Before each work shift and after any occurrence that could affect structural integrity✓

A competent person inspects scaffolds and components before each work shift and after any occurrence which could affect the scaffold's structural integrity.29 CFR 1926.451(f)(3)

OSHA Construction Safety

A scaffold is erected near an uninsulated 7,200-volt power line. Under 1926.451(f)(6), the scaffold and any conductive material on it must stay at least:

  • a.10 feet from the line✓
  • b.50 feet from the line
  • c.1 foot from the line
  • d.3 feet from the line

For uninsulated lines of less than 50 kV the minimum clearance is 10 feet, with more distance added above 50 kV. The 3-foot figure applies only to insulated lines under 300 volts.29 CFR 1926.451(f)(6)

OSHA Construction Safety

Under 1926.451(h)(4), a toeboard on a scaffold platform must be at least how high?

  • a.1-1/2 inches
  • b.24 inches
  • c.12 inches
  • d.3-1/2 inches✓

Toeboards are at least 3-1/2 inches high from the top edge to the walking surface, to keep tools and materials from falling on people below.29 CFR 1926.451(h)(4)(ii)

OSHA Construction Safety

Scaffold planks 10 feet long or less must extend over the centreline of their supports, under 1926.451(b)(4) and (b)(5), by at least 6 inches and not more than:

  • a.12 inches✓
  • b.8 inches
  • c.30 inches
  • d.48 inches

Unless cleated or restrained, each plank end extends at least 6 inches over its support, and for platforms 10 feet or less in length not more than 12 inches, so that the end cannot tip when stepped on.29 CFR 1926.451(b)(4), (b)(5)

OSHA Construction Safety

Under 1926.350(a), oxygen cylinders in storage must be separated from fuel-gas cylinders by at least 20 feet, or by a noncombustible barrier at least:

  • a.1 foot high with a fire-resistance rating of at least five minutes
  • b.5 feet high with a fire-resistance rating of at least one-half hour✓
  • c.3 feet high with no fire-resistance rating required at all
  • d.10 feet high with a fire-resistance rating of at least four hours

Oxygen cylinders in storage are separated from fuel-gas cylinders or combustible materials by 20 feet or by a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour.29 CFR 1926.350(a)(10)

OSHA Construction Safety

Under 1926.350(d), the valve on an acetylene or other fuel-gas cylinder that is in use should not be opened more than:

  • a.2-1/2 turns
  • b.1-1/2 turns✓
  • c.5 turns
  • d.10 turns

Fuel-gas cylinder valves are opened slowly and not more than 1-1/2 turns, so the valve can be closed quickly in an emergency; a special wrench stays on the stem.29 CFR 1926.350(d)(2)

OSHA Construction Safety

Before compressed gas cylinders are moved, 1926.350(a) requires that, unless they are secured on a special carrier:

  • a.Cylinders are laid flat and rolled along the floor by hand
  • b.Regulators are left attached and the valves are opened fully
  • c.Regulators are removed and valve protection caps are put in place✓
  • d.Cylinders are emptied to the air and their valves are removed

Unless cylinders are firmly secured on a special carrier intended for the purpose, regulators are removed and valve protection caps put in place before the cylinders are moved.29 CFR 1926.350(a)(6)

OSHA Construction Safety

Why does 1926.350(i) require oxygen cylinders and fittings to be kept away from oil and grease?

  • a.Oil and grease cause the oxygen regulator to read lower than it should
  • b.Oil and grease make the hose connections too slippery to tighten
  • c.Oil and grease can ignite violently in the presence of oxygen under pressure✓
  • d.Oil and grease corrode the brass of the cylinder valve within a few days

Oxygen cylinders, caps, valves, regulators and hoses are kept free of oil or greasy substances and are not handled with oily hands or gloves, because oil can burn explosively in pressurised oxygen.29 CFR 1926.350(i)

OSHA Construction Safety

Under 1926.350(b), cylinders containing oxygen or acetylene may not be:

  • a.Secured in an upright position
  • b.Stored with their caps on
  • c.Taken into confined spaces✓
  • d.Moved on a cylinder cart

Cylinders containing oxygen, acetylene or other fuel gas are not taken into confined spaces, where a leak would quickly create a fire or asphyxiation hazard. Caps, upright storage and carts are all required practice.29 CFR 1926.350(b)(4)

OSHA Construction Safety

Under 1926.350(f), oxygen and fuel-gas hoses must be:

  • a.Taped together along their full length with no gaps
  • b.Replaced every 30 days whatever their condition
  • c.Identical in colour and fitted with the same thread
  • d.Easily distinguishable from each other and not interchangeable✓

Fuel-gas and oxygen hoses are easily distinguishable by colour or surface feel and are not interchangeable; when taped together, not more than 4 inches in every 12 is covered.29 CFR 1926.350(f)

OSHA Construction Safety

A plumber will braze copper near wood framing. Under 1926.352, the employer must:

  • a.Wet the framing once at the start of the day and take no other step
  • b.Keep suitable fire extinguishing equipment immediately available in the work area✓
  • c.Post a sign and proceed, since brazing does not create a fire hazard
  • d.Remove the building's smoke detectors until the brazing is finished

Suitable fire extinguishing equipment is immediately available in the work area and maintained ready for use; where normal precautions are not enough, additional personnel watch for fire during and after the work.29 CFR 1926.352(d), (e)

OSHA Construction Safety

Under 1926.302(b)(4), compressed air may be used for cleaning only where the pressure is reduced to less than:

  • a.30 psi, with effective chip guarding and personal protective equipment✓
  • b.150 psi, with no chip guarding or personal protective equipment needed
  • c.90 psi, with effective chip guarding and personal protective equipment
  • d.300 psi, with no chip guarding or personal protective equipment needed

Compressed air is not used for cleaning except where reduced to less than 30 psi and then only with effective chip guarding and personal protective equipment.29 CFR 1926.302(b)(4)

OSHA Construction Safety

Under 1926.302(a), an electric power-operated hand tool must be:

  • a.Used only with its trigger switch taped in the on position
  • b.Fitted with a two-wire cord and no ground of any kind
  • c.Operated from a generator rather than building power
  • d.Of the approved double-insulated type, or grounded✓

Electric power-operated tools are either of the approved double-insulated type or grounded in accordance with the electrical subpart; cords are not used for hoisting or lowering tools.29 CFR 1926.302(a)

OSHA Construction Safety

Under 1926.302(e), a powder-actuated tool may be operated only by:

  • a.An apprentice, provided the tool is loaded before the shift begins
  • b.Any employee, provided a supervisor is somewhere on the project
  • c.An employee who has been trained in the operation of the particular tool✓
  • d.A licensed master plumber, whatever training has been given

Only employees trained in the operation of the particular tool may use a powder-actuated tool; it is tested each day before loading, and not loaded until just before use.29 CFR 1926.302(e)

OSHA Construction Safety

Under 1926.303(c), the work rest on a floor or bench-mounted grinder must be kept adjusted to within what distance of the wheel?

  • a.1/2 inch
  • b.2 inches
  • c.1/8 inch✓
  • d.1 inch

Work rests are kept at a distance not to exceed 1/8 inch from the surface of the wheel, so that the work cannot be pulled between the rest and the wheel.29 CFR 1926.303(c)(2)

OSHA Construction Safety

Under 1926.100, head protection must be worn by employees working where:

  • a.There is a possible danger of head injury from impact, falling or flying objects, or electrical shock and burns✓
  • b.The work is done outdoors and the temperature is forecast to rise above 90 degrees Fahrenheit during the working shift
  • c.The building is more than three stories high, whatever work the employee is doing
  • d.The general contractor's company logo has to be displayed to visitors

Employees working in areas where there is a possible danger of head injury from impact, from falling or flying objects, or from electrical shock and burns are protected by protective helmets.29 CFR 1926.100(a)

Texas Accessibility Standards

In Texas, the Texas Accessibility Standards are administered by:

  • a.The Texas Commission on Environmental Quality field office
  • b.The Texas State Board of Plumbing Examiners
  • c.The Railroad Commission of Texas
  • d.The Texas Department of Licensing and Regulation✓

The Architectural Barriers programme of the Texas Department of Licensing and Regulation administers the Texas Accessibility Standards under Government Code Chapter 469.Tex. Gov't Code Ch. 469; 2012 TAS §101

Texas Accessibility Standards

Under TAS §604.2, the centreline of a wheelchair accessible water closet must be how far from the side wall or partition?

  • a.10 to 12 inches
  • b.16 to 18 inches✓
  • c.30 to 36 inches
  • d.22 to 24 inches

The water closet centreline is 16 inches minimum and 18 inches maximum from the side wall or partition; ambulatory accessible compartments use 17 to 19 inches.2012 TAS §604.2

Texas Accessibility Standards

Under TAS §604.4, the seat of an accessible water closet for adults must be how high above the finish floor, measured to the top of the seat?

  • a.12 to 14 inches
  • b.21 to 24 inches
  • c.17 to 19 inches✓
  • d.26 to 30 inches

The seat height is 17 inches minimum and 19 inches maximum, which matches a wheelchair seat for transfer. Seats may not be sprung to return to a lifted position.2012 TAS §604.4

Texas Accessibility Standards

Under TAS §604.3, the clearance around an accessible water closet must be at least 60 inches measured perpendicular from the side wall, and at least how deep measured from the rear wall?

  • a.56 inches✓
  • b.96 inches
  • c.30 inches
  • d.42 inches

Clearance around the water closet is 60 inches minimum from the side wall and 56 inches minimum from the rear wall.2012 TAS §604.3.1

Texas Accessibility Standards

Under TAS §609.4, grab bars at a water closet are mounted with the top of the gripping surface how high above the finish floor?

  • a.18 to 24 inches
  • b.33 to 36 inches✓
  • c.54 to 60 inches
  • d.42 to 48 inches

Grab bars are installed horizontally, 33 inches minimum and 36 inches maximum above the finish floor to the top of the gripping surface.2012 TAS §609.4

Texas Accessibility Standards

Under TAS §604.5.1, the side wall grab bar at a water closet must be at least how long?

  • a.24 inches
  • b.12 inches
  • c.42 inches✓
  • d.72 inches

The side wall grab bar is 42 inches long minimum, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall.2012 TAS §604.5.1

Texas Accessibility Standards

Under TAS §604.5.2, the rear wall grab bar at a water closet must generally be at least how long?

  • a.18 inches
  • b.36 inches✓
  • c.12 inches
  • d.60 inches

The rear wall grab bar is 36 inches long minimum, extending from the centreline of the water closet 12 inches minimum on one side and 24 inches minimum on the other.2012 TAS §604.5.2

Texas Accessibility Standards

Under TAS §609.3, the space between a grab bar and the wall must be:

  • a.1/4 inch
  • b.1-1/2 inches✓
  • c.6 inches
  • d.3-1/2 inches

The space between the wall and the grab bar is 1-1/2 inches, wide enough for a grip but too narrow for an arm to slip through and be trapped.2012 TAS §609.3

Texas Accessibility Standards

Under TAS §609.8, a grab bar and its mounting must withstand a vertical or horizontal force of at least:

  • a.1,000 pounds
  • b.50 pounds
  • c.250 pounds✓
  • d.100 pounds

Allowable stresses may not be exceeded when a force of 250 pounds is applied at any point on the grab bar, fastener, mounting device or supporting structure. Blocking in the wall has to be planned at rough-in.2012 TAS §609.8

Texas Accessibility Standards

Under TAS §604.6, the flush control of an accessible water closet must be located:

  • a.On the side nearest the wall
  • b.On the rear wall behind the seat cover
  • c.On the floor beside the bowl
  • d.On the open side of the water closet✓

Flush controls are hand operated or automatic; hand-operated controls are on the open side of the water closet (except in ambulatory compartments) and within reach range.2012 TAS §604.6