Under IPC §704.1, a 2-inch horizontal drain must be installed with a uniform slope of at least:
- a.1/2 inch per foot
- b.1/4 inch per foot✓
- c.1/8 inch per foot
- d.1/16 inch per foot
Horizontal drainage pipe 2-1/2 inches and smaller slopes at least 1/4 inch per foot. One-eighth inch per foot is the minimum for 3- to 6-inch pipe and 1/16 inch per foot for 8 inches and larger.IPC §704.1
A 4-inch building drain is being laid. The minimum slope allowed by IPC §704.1 is:
- a.1/8 inch per foot✓
- b.1/4 inch per foot
- c.1/2 inch per foot
- d.1/16 inch per foot
Pipe from 3 to 6 inches may be laid at 1/8 inch per foot. One-quarter inch is required only for 2-1/2 inches and smaller, and 1/16 inch only for 8 inches and larger.IPC §704.1
A 3-inch drain runs 40 feet at the minimum slope of 1/8 inch per foot. The total fall over the run is:
- a.10 inches
- b.5 inches✓
- c.2-1/2 inches
- d.40 inches
Fall equals slope times length: 1/8 inch × 40 feet = 5 inches. Ten inches would be the fall at 1/4 inch per foot, and 2-1/2 inches at 1/16 inch per foot.IPC §704.1
A 2-inch drain must drop 6 inches between two points at exactly 1/4 inch per foot. How long is the run?
- a.12 feet
- b.48 feet
- c.24 feet✓
- d.18 feet
Length equals fall divided by slope: 6 inches ÷ 1/4 inch per foot = 24 feet. Forty-eight feet would be the run at 1/8 inch per foot.IPC §704.1
Under IPC §704.2, the size of drainage piping in the direction of flow:
- a.May not be reduced✓
- b.May be reduced by one pipe size at each stack
- c.May be reduced where the slope is doubled
- d.May be reduced downstream of each cleanout
Drainage pipe never gets smaller in the direction of flow, because solids would lodge at the reduction. A 4-by-3-inch closet bend is specifically not treated as a reduction. Slope and cleanouts do not create exceptions.IPC §704.2
Which fitting does IPC §706.3 allow for a change of direction from horizontal to vertical only, and not from vertical to horizontal?
- a.A sanitary tee✓
- b.A wye with an eighth bend
- c.A combination wye and eighth bend
- d.A long-sweep quarter bend
A sanitary tee has a short radius and is used only where flow turns from horizontal to vertical. Wyes, combination fittings and long sweeps may be used in any change of direction, including vertical to horizontal.IPC §706.3
Two water closets are set back to back on a double sanitary tee. Under IPC §706.3, this is permitted only where the horizontal developed length between each closet outlet and the fitting is at least:
- a.36 inches
- b.6 inches
- c.12 inches
- d.18 inches✓
Back-to-back water closets with pressure-assisted or similar flushing action can throw waste across a double sanitary tee; the fitting is allowed where each closet outlet is at least 18 inches of developed length from it. Otherwise a double wye pattern is used.IPC §706.3
Under IPC §708.1.1, cleanouts on a horizontal drain inside a building are spaced no more than:
- a.50 feet apart
- b.200 feet apart
- c.150 feet apart
- d.100 feet apart✓
Horizontal drainage pipes have cleanouts at intervals of not more than 100 feet. The other spacings are not the code figure for building drains and branches.IPC §708.1.1
A cleanout is required under IPC §708.1.3 near:
- a.The junction of the building drain and the building sewer✓
- b.The top of every vent stack where it passes through the roof
- c.The connection of each lavatory trap arm to the wall
- d.The midpoint of every horizontal branch over 5 feet long
A cleanout is installed at the junction of the building drain and building sewer, inside or outside the building wall. Fixture trap arms are reached through the trap, vents do not take cleanouts at the roof, and short branches do not need them at mid-length.IPC §708.1.3
A horizontal drain makes three 90-degree changes of direction within 30 feet. Under IPC §708.1.4, how many cleanouts are required for these changes?
- a.Two, because cleanouts are required at alternate changes
- b.One, because a single cleanout serves each 40 feet of run✓
- c.None, because cleanouts are required only at stack bases
- d.Three, because every change over 45 degrees needs its own
A cleanout is required at each change of direction greater than 45 degrees, but where more than one change occurs in a run, only one cleanout is required for each 40 feet of developed length. Three changes within 30 feet therefore need one.IPC §708.1.4
Under IPC §708.1.5, a cleanout on a 6-inch building sewer must be at least:
- a.4 inches✓
- b.6 inches
- c.3 inches
- d.2 inches
Cleanouts are the same nominal size as the pipe up to 4 inches; for pipes larger than 4 inches the cleanout is at least 4 inches. Two and 3 inches are too small to pass cleaning equipment for a 6-inch line.IPC §708.1.5
A 3-inch cleanout is installed in a mechanical room. Under IPC §708.1.9, the clearance in front of the cleanout for rodding must be at least:
- a.18 inches✓
- b.12 inches
- c.36 inches
- d.6 inches
Cleanouts on pipes 6 inches and smaller need at least 18 inches of clearance in front; cleanouts on 8-inch and larger pipes need 36 inches. Six and 12 inches do not leave room to feed a cable.IPC §708.1.9
In the IPC drainage fixture unit table (§709.1), a private 1.6-gallon-per-flush water closet is rated at:
- a.2 drainage fixture units
- b.6 drainage fixture units
- c.3 drainage fixture units✓
- d.1 drainage fixture unit
A 1.6 gpf private water closet carries 3 dfu and a public one 4 dfu. Lavatories are 1 dfu, and tubs, showers and kitchen sinks are 2 dfu.IPC §709.1
Under IPC §709.1, a lavatory is assigned how many drainage fixture units?
- a.4
- b.3
- c.2
- d.1✓
A lavatory is 1 dfu. Two dfu is the value for a bathtub, shower, kitchen sink or residential clothes washer, and 3 or 4 dfu applies to water closets.IPC §709.1
A fixture is not listed in the fixture unit table and has a 2-inch trap. Under IPC §709.2, its load is taken as:
- a.5 drainage fixture units
- b.1 drainage fixture unit
- c.2 drainage fixture units
- d.3 drainage fixture units✓
Unlisted fixtures are rated by trap size: 1-1/4 inch is 1 dfu, 1-1/2 inch is 2 dfu, 2 inch is 3 dfu, 2-1/2 inch is 4, 3 inch is 5 and 4 inch is 6.IPC §709.2
A sump pump discharges continuously into the sanitary drain at 10 gallons per minute. Under IPC §709.3, this load is counted as:
- a.20 drainage fixture units✓
- b.10 drainage fixture units
- c.40 drainage fixture units
- d.5 drainage fixture units
Continuous or semicontinuous flow is rated at 2 drainage fixture units for each gallon per minute: 10 gpm × 2 = 20 dfu. Ten dfu would be one unit per gpm, which is not the code value.IPC §709.3
A house has one 1.6 gpf water closet (3 dfu), one lavatory (1 dfu), one bathtub (2 dfu) and one kitchen sink (2 dfu) on a horizontal branch. The total load on the branch is:
- a.6 drainage fixture units
- b.8 drainage fixture units✓
- c.10 drainage fixture units
- d.12 drainage fixture units
Add the individual values: 3 + 1 + 2 + 2 = 8 dfu. The branch is then sized from the horizontal branch table for that load.IPC §§709.1, 710.1
Under the horizontal branch table of IPC §710.1, the largest load a 2-inch horizontal fixture branch may carry is:
- a.6 drainage fixture units✓
- b.20 drainage fixture units
- c.3 drainage fixture units
- d.12 drainage fixture units
A 2-inch horizontal branch is limited to 6 dfu; 1-1/2 inch carries 3, 2-1/2 inch carries 12 and 3 inch carries 20. A water closet may not discharge into a branch smaller than 3 inches.IPC §710.1
A below-grade bathroom drains to a sewage ejector. Under IPC §712.2, the ejector's discharge pipe must be fitted with:
- a.A check valve and a full-open valve on the discharge side of the check✓
- b.A vacuum breaker and a relief valve at the top of the discharge riser
- c.A pressure-reducing valve and a strainer on the discharge side of it
- d.A trap and a cleanout between the pump and the gravity building drain
The discharge has a check valve to stop backflow into the sump and a full-open valve downstream of it so the check and pump can be serviced. Regulators, vacuum breakers and traps are not used on ejector discharge piping.IPC §712.2
Under IPC §712.3.2, a sewage sump pit must be at least:
- a.36 inches in diameter and 60 inches deep
- b.24 inches in diameter and 48 inches deep
- c.12 inches in diameter and 12 inches deep
- d.18 inches in diameter and 24 inches deep✓
The sump pit is not less than 18 inches in diameter and 24 inches deep unless otherwise approved, and it has a gastight removable cover and a vent. The other sizes are not the code minimum.IPC §712.3.2
A sewage ejector serves a water closet in a basement. Under IPC §712.4.2, the ejector discharge pipe must be at least:
- a.3/4 inch
- b.2 inches✓
- c.1-1/4 inches
- d.4 inches
The discharge from a sewage pump or ejector that handles solids is at least 2 inches (grinder pumps and macerating toilet systems are treated separately and may use smaller pipe per their listing). Four inches is not required.IPC §712.4.2
A basement floor drain is lower than the cover of the next upstream manhole in the public sewer. Under IPC §714.1, the drain must be protected by:
- a.A pressure vacuum breaker
- b.A trap primer
- c.A running trap
- d.A backwater valve✓
Fixtures with flood level rims below the elevation of the next upstream manhole cover are protected by a backwater valve, which closes when the sewer surcharges. Vacuum breakers are water supply devices, and trap primers and running traps do not stop reverse flow.IPC §714.1
A two-story house has a backwater valve protecting the basement fixtures. Under IPC §714.1, the fixtures on the upper floors, which are above the manhole cover elevation:
- a.Must each have a backwater valve of their own
- b.Must also discharge through the backwater valve
- c.Must not discharge through the backwater valve✓
- d.Must discharge through a separate building sewer
Fixtures above the manhole cover elevation may not drain through the backwater valve, because when the valve closes their discharge would flood the basement. They need no backwater valve and no separate sewer; they connect downstream of the valve.IPC §714.1
Which joint in drainage piping is prohibited by IPC §707.1?
- a.A shielded hubless coupling
- b.A saddle-type fitting✓
- c.A compression gasket joint
- d.A solvent-cemented PVC joint
Prohibited joints include cement or concrete joints, mastic or hot-pour bituminous joints, saddle-type fittings and solvent-cement joints between different types of plastic pipe. Solvent-cemented PVC, shielded couplings and compression gaskets are all approved methods.IPC §707.1
A PVC building drain must be connected to an existing ABS building sewer. Under IPC §705, the two plastics are joined with:
- a.An approved mechanical transition coupling or adapter✓
- b.A bead of silicone sealant inside a PVC slip coupling
- c.ABS solvent cement that is applied to both pipe ends
- d.PVC solvent cement that is applied to both pipe ends
Different plastics are joined with approved adapter or transition fittings, such as a shielded elastomeric coupling. Ordinary solvent cement joints between different plastics are prohibited, and sealant is not a joint method.IPC §§705.16, 707.1
Under IPC §705, a solvent-cemented joint in PVC drain pipe may be made without primer only where:
- a.The joint is tested with air at 5 psi before the cement has set
- b.The air temperature at the time the joint is made is above 90°F
- c.The cement is certified for it and the DWV pipe is 4 inches or smaller, non-pressure✓
- d.The pipe is larger than 6 inches and the joint will be buried under a concrete slab
The 2018 code allows primerless joints only for non-pressure DWV pipe 4 inches and smaller using a third-party certified cement that conforms to ASTM D2564. Size over 6 inches, heat and testing do not waive primer.IPC §705.11.2
Hubless cast-iron soil pipe is joined with:
- a.A solvent cement made for joining cast iron to plastic pipe
- b.Threaded ends cut on the job with a standard pipe die
- c.Molten lead poured over packed oakum in the bell end of each length of pipe
- d.A shielded elastomeric sleeve coupling tightened to the specified torque✓
Hubless pipe has no bell; it is joined with an elastomeric sealing sleeve and a stainless-steel shield and clamps conforming to the referenced standards. Lead and oakum is for hub-and-spigot pipe, and cast-iron soil pipe is not threaded or cemented.IPC §705 (cast iron mechanical joints)
Under IPC §701.2, a building in which plumbing fixtures are installed must connect to a public sewer where:
- a.The building is more than one story high
- b.The owner chooses a sewer over a septic system
- c.A public sewer is available to the premises✓
- d.The building has more than two bathrooms
Buildings with plumbing fixtures connect to a public sewer where one is available; otherwise an approved private sewage disposal system is used. Owner preference, fixture count and height do not decide it.IPC §701.2
The extension of drain piping more than 2 feet past the last connection, with no fixture on it, is a "dead end". Under IPC §704.5, dead ends are:
- a.Permitted, where the dead end is capped and an air admittance valve is fitted
- b.Prohibited, except where needed to extend a cleanout to an accessible point✓
- c.Prohibited, except where the dead end is larger than the drain that it joins
- d.Permitted, where the dead end slopes at 1/4 inch per foot back to the drain
Dead ends collect solids and are prohibited; the only allowance is a cleanout extension brought to an accessible location. Slope, a cap or a larger size does not make a dead end acceptable.IPC §704.5
In the code definitions, the "building drain" ends and the "building sewer" begins:
- a.10 feet outside the building wall
- b.At the inside face of the building wall
- c.At the property line of the lot
- d.30 inches outside the building wall✓
The building drain is the lowest piping that receives the discharge of the drainage system and extends 30 inches beyond the exterior walls, where the building sewer begins. The other points are not the code's dividing line.IPC §202
A "branch interval" on a drainage stack is defined in IPC §202 as a vertical length of stack of at least:
- a.8 feet, within which the horizontal branches of one story connect✓
- b.12 feet, within which the horizontal branches of two stories connect
- c.4 feet, within which the horizontal branches of one story connect
- d.20 feet, within which the horizontal branches of two stories connect
The 2018 IPC defines a branch interval as a vertical distance of 8 feet or more in developed length between the connections of horizontal branches to a drainage stack, measured down from the highest branch connection; in practice it corresponds to a story. It is used to size stacks and decide when a vent stack is needed.IPC (2018) §202
A "stack" in the drainage system is:
- a.A fitting that joins the fixture drain to the trap and maintains the seal of water in the trap
- b.A general term for any vertical line of soil, waste or vent piping extending through at least one story✓
- c.A horizontal pipe that carries the discharge of two or more fixture branches to the building drain
- d.The part of the drainage system that extends from the building wall to the public sewer main
A stack is any main vertical DWV line extending through one or more stories. The horizontal collector is a branch, the piping outside the wall is the building sewer, and the last choice describes no code term.IPC §202
A horizontal branch connects to the base of a tall drainage stack. Under IPC §704.3, a horizontal branch may not connect to the building drain within how far downstream of the stack?
- a.10 pipe diameters✓
- b.40 pipe diameters
- c.5 pipe diameters
- d.2 pipe diameters
Horizontal branches connect to the horizontal drain at least 10 pipe diameters downstream from the base of a stack, clear of the turbulent hydraulic jump zone. The smaller distances fall inside that zone.IPC §704.3
A plumber sets a closet flange on a 4-by-3-inch closet bend that connects to a 3-inch drain. Under IPC §704.2, this arrangement is:
- a.Acceptable; a 4-by-3 closet bend is not considered a reduction in size✓
- b.Acceptable only if the water closet is a pressure-assisted model
- c.A violation unless a cleanout is installed at the closet bend
- d.A violation; the drain must be 4 inches all the way from the flange
The code states that a 4-inch by 3-inch water closet connection is not a reduction in size. A 3-inch drain is adequate for a water closet, and no special closet type or cleanout is needed.IPC §704.2
Why is excessive slope, as well as too little slope, a problem on a small horizontal drain?
- a.The vent piping fills with waste and loses its air passage
- b.The pipe wall wears through quickly from the speed of the waste stream
- c.The liquid can outrun the solids and leave them behind in the pipe✓
- d.The trap seals upstream are pushed out through the fixtures
Drains are designed to flow partly full at a scouring velocity; on a very steep small line, water can run ahead of solids and strand them. Wall wear and blown traps are not the usual result of slope alone.IPC §704.1