Texas Journeyman Plumber Exam — All Questions
35 questions
IPC §901.2.1 requires the venting system to protect trap seals so that no trap is subjected to a pressure differential of more than:
- a.2 inches of water column
- b.4 inches of water column
- c.1/4 inch of water column
- d.1 inch of water column✓
The vent system is designed so that pneumatic pressure differences at trap seals do not exceed 1 inch of water column. A 2-inch trap seal survives that; larger differentials siphon or blow the seal.IPC §901.2.1
Under IPC §909.1, the developed length of a 1-1/2-inch fixture drain from the trap weir to the vent fitting may not exceed:
- a.6 feet✓
- b.5 feet
- c.3 feet 6 inches
- d.8 feet
The trap-to-vent table allows 5 feet for a 1-1/4-inch trap, 6 feet for 1-1/2 inch, 8 feet for 2 inch, 12 feet for 3 inch and 16 feet for 4 inch. The 3 feet 6 inches figure comes from a different model code.IPC §909.1
A 2-inch trap serves a shower. Under IPC §909.1, the trap arm may be no longer than:
- a.8 feet✓
- b.12 feet
- c.5 feet
- d.6 feet
A 2-inch fixture drain sloped at 1/4 inch per foot may run 8 feet from trap weir to vent. Five and 6 feet apply to 1-1/4 and 1-1/2 inch traps, and 12 feet to 3-inch traps.IPC §909.1
Under IPC §909.2, the total fall of a fixture drain between the trap weir and the vent connection may not exceed:
- a.Two pipe diameters
- b.One-half pipe diameter
- c.One pipe diameter✓
- d.Four pipe diameters
If the trap arm drops more than its own diameter, the vent opening ends up below the trap weir and the arm acts like an S-trap that siphons itself. Water closets are excepted from the limit.IPC §909.2
A vent is connected to a fixture drain right at the top of the trap bend. Under IPC §909.3 this "crown vent" is prohibited because the vent connects within how far of the trap weir?
- a.Six pipe diameters
- b.Four pipe diameters
- c.Two pipe diameters✓
- d.Ten pipe diameters
A vent may not be installed within two pipe diameters of the trap weir. A vent that close clogs with debris thrown up by the flow and speeds evaporation of the seal.IPC §909.3
Under IPC §906.2, an individual vent must be at least one-half the diameter of the drain it serves, and in no case smaller than:
- a.2-1/2 inches
- b.1 inch
- c.1-1/4 inches✓
- d.1-1/2 inches
Vents other than stack vents and vent stacks are at least half the required diameter of the drain served and not less than 1-1/4 inches. Smaller pipe clogs and frosts; 2 inches is not a universal minimum.IPC §906.2
A 3-inch drain is served by an individual vent that is 55 feet in developed length. Under IPC §906.2, the vent must be at least:
- a.2 inches: one-half the drain size, increased one pipe size for length over 40 feet✓
- b.1-1/4 inches: the minimum size that the code accepts for any individual vent
- c.1-1/2 inches: one-half the drain size, with no increase required for its length
- d.3 inches: the same size as the drain, for any vent of more than 40 feet in length
Half of 3 inches is 1-1/2 inches; vents exceeding 40 feet in developed length are increased one nominal pipe size for the full length, giving 2 inches. Matching the drain size is not required.IPC §906.2
Under IPC §905.4, a dry vent must rise vertically to at least what height before it may run horizontally?
- a.36 inches above the finished floor of the room
- b.2 inches above the trap weir of the fixture served
- c.12 inches below the flood level rim of the fixture served
- d.6 inches above the flood level rim of the fixture served✓
Every dry vent rises vertically to a point at least 6 inches above the flood level rim of the highest trap or fixture being vented before offsetting, so that a stoppage cannot turn the vent into a drain. Height above the floor or trap weir is not the measure.IPC §905.4
Under IPC §905.3, where a vent connects to a horizontal drain, the vent pipe must take off:
- a.From the bottom of the drain pipe
- b.Above the centreline of the drain pipe✓
- c.Below the centreline of the drain pipe
- d.Level with the invert of the drain
Vents connect above the horizontal centreline of the drain so that waste does not flow into and block the vent. Connections at or below the centreline fill with solids.IPC §905.3
Vent pipes must be sloped and connected, under IPC §905.2, so that they:
- a.Fall away from the drain toward the roof
- b.Stay level between the drain and the stack
- c.Hold a seal of water at each change of direction
- d.Drain back to the drainage pipe by gravity✓
Vent and branch vent pipes are graded so that condensation and rainwater drain back to the drainage system by gravity. A vent that holds water is blocked to air flow.IPC §905.2
Under IPC §903.5, an open vent terminal may not be within 10 feet horizontally of a window or air intake unless it is at least how far above the top of the opening?
- a.10 feet
- b.3 feet✓
- c.1 foot
- d.6 feet
A vent terminal is not located directly beneath a door, window or air intake, nor within 10 feet horizontally of one unless it is at least 3 feet above the top of the opening. One foot is too little to keep sewer gas out.IPC §903.5
A vent terminates through a roof that is used as a sun deck. Under IPC §903.1, the vent must extend above the roof at least:
- a.6 inches
- b.7 feet✓
- c.2 feet
- d.10 feet
Where a roof is used for any purpose other than weather protection, such as a deck or promenade, vents extend at least 7 feet above it so gases discharge above head height. Ordinary roofs use the locally set height.IPC §903.1
In a cold-climate jurisdiction where IPC §903.2 applies, a vent extension through the roof must be at least:
- a.1-1/4 inches in diameter
- b.6 inches in diameter
- c.2 inches in diameter
- d.3 inches in diameter✓
Where the design temperature is below 0°F, vent extensions through the roof are at least 3 inches so that frost does not close the opening, with any increase made at least 1 foot inside the building's thermal envelope. Most of Texas is above that threshold.IPC §903.2
A sidewall vent terminal is allowed under IPC §903.6 only where it is at least:
- a.5 feet from the lot line and 7 feet above the highest adjacent grade
- b.25 feet from the lot line and 20 feet above the highest adjacent grade
- c.3 feet from the lot line and 1 foot above the highest adjacent grade
- d.10 feet from the lot line and 10 feet above the highest adjacent grade✓
Vent terminals through a wall are at least 10 feet from the lot line and 10 feet above the highest adjacent grade within 10 feet horizontally, are protected against birds and rodents, and do not terminate under an overhang with soffit vents.IPC §903.6
Under IPC §904.2, a vent stack is required for a drainage stack that has:
- a.Ten or more branch intervals
- b.Five or more branch intervals✓
- c.Two or more branch intervals
- d.Three or more branch intervals
Every drainage stack of five branch intervals or more needs a vent stack, connected at or below the lowest branch. Shorter stacks rely on the stack vent. Ten branch intervals is where relief vents come in.IPC §904.2
Under IPC §904.1, every building's sanitary drainage system must have at least one vent that:
- a.Is 4 inches in diameter
- b.Ends in the attic space
- c.Has an air admittance valve
- d.Extends to the outdoors✓
At least one vent pipe must extend to the outdoors, so that positive pressure in the system can be relieved; air admittance valves only admit air. Attic termination is prohibited, and no fixed 4-inch size applies.IPC §§904.1, 918.7
A lavatory and a kitchen sink on opposite sides of a wall connect at the same level to a vertical drain and share one vent. Under IPC §911, this is:
- a.A common vent✓
- b.A wet vent
- c.A circuit vent
- d.A relief vent
An individual vent serving two fixture drains is a common vent; when the drains connect at the same level, the vent rises from their intersection. Circuit vents serve a battery of fixtures, wet vents carry waste, and relief vents equalise pressure on stacks.IPC §911.1
Two fixtures connect to a vertical drain at different levels and share a common vent. Under IPC §911.2, the upper fixture may NOT be:
- a.A drinking fountain
- b.A water closet✓
- c.A lavatory
- d.A bathtub
Where fixture drains connect at different levels, the vertical pipe between them is the vent for the lower fixture, and the upper fixture may not be a water closet, whose discharge would fill the pipe. Lavatories, tubs and fountains are acceptable upper fixtures within the fixture unit limits.IPC §911.2
Under IPC §912.1, a horizontal wet vent may serve any combination of fixtures within:
- a.Four bathroom groups located on two adjacent floor levels
- b.Any number of bathroom groups on the same floor level
- c.One bathroom group and one kitchen on the same floor level
- d.Two bathroom groups located on the same floor level✓
Horizontal wet venting covers fixtures within one or two bathroom groups on the same floor level. Kitchen sinks, fixtures on other floors and larger groupings fall outside the method.IPC §912.1
A horizontal wet vent serves a bathroom group. Under IPC §912.2, the dry vent for the wet-vented section may connect to:
- a.Any bathroom group fixture drain, except that of an emergency floor drain✓
- b.The building drain at any point downstream of the wet-vented section
- c.A kitchen sink drain located on the floor above the bathroom group
- d.The water closet fixture drain only, and to no other fixture in the group
The required dry vent is an individual or common vent for any bathroom group fixture other than an emergency floor drain. It need not be at the water closet, and a connection from another floor or downstream of the wet vent does not vent the section.IPC §912.2
Under IPC §912.3, a 2-inch wet vent may carry a drainage load of no more than:
- a.1 drainage fixture unit
- b.12 drainage fixture units
- c.8 drainage fixture units
- d.4 drainage fixture units✓
The wet vent size table allows 1 dfu on 1-1/2 inch, 4 dfu on 2 inch, 6 dfu on 2-1/2 inch and 12 dfu on 3 inch. The dry vent connecting to it is sized for the largest required drain in the wet vent.IPC §912.3
Under IPC §914.1, one circuit vent may serve a battery of no more than:
- a.12 fixtures connected to a horizontal branch drain
- b.24 fixtures connected to a horizontal branch drain
- c.8 fixtures connected to a horizontal branch drain✓
- d.4 fixtures connected to a horizontal branch drain
A circuit vent serves up to eight fixtures on a horizontal branch; each fixture drain connects horizontally to the branch, which is treated as a vent for its length. Larger batteries need more than one circuit.IPC §914.1
Under IPC §914.2, the circuit vent connection to the horizontal branch is made:
- a.Downstream of the last fixture drain on the branch
- b.At the base of the stack that the branch joins
- c.Upstream of the first fixture, at the cleanout
- d.Between the two most upstream fixture drains✓
The circuit vent takes off between the two upstream-most fixture drains so that the branch itself, washed by the first fixture, serves as a vent for the rest. A downstream or stack connection is a relief vent, not the circuit vent.IPC §914.2
Under IPC §914.3, the slope of a circuit-vented horizontal branch may not exceed:
- a.1 inch per foot✓
- b.1/8 inch per foot
- c.1/4 inch per foot
- d.2 inches per foot
The circuit-vented branch is sized as a horizontal branch and its slope is limited to 1 unit vertical in 12 horizontal, so that air can move above the flow. The smaller figures are minimum drain slopes, not the maximum.IPC §914.3
Under IPC §915.1, a combination waste and vent system may serve only:
- a.Water closets, urinals, bidets and clinical sinks
- b.Floor drains, sinks, lavatories and drinking fountains✓
- c.Food waste disposers, floor sinks and mop sinks
- d.Bathtubs, showers, clothes washers and domestic dishwashers
Combination waste and vent systems are limited to floor drains, sinks, lavatories and drinking fountains, and they may not receive the discharge of a food waste disposer or clinical sink. Water closets and urinals are never served by this method.IPC §915.1
An island kitchen sink is vented under IPC §916. Before the vent turns down to run below the floor, it must rise:
- a.To the underside of the roof deck above the island
- b.Above the drainage outlet of the fixture being vented✓
- c.To 42 inches above the finished floor of the kitchen
- d.Only to the level of the trap weir of the sink
The island fixture vent rises vertically above the drainage outlet of the fixture before offsetting horizontally or downward, and cleanouts allow the vent to be rodded. It does not have to reach the roof deck at that point or a fixed 42-inch height.IPC §916.2
Under IPC §916.1, island fixture venting is permitted for:
- a.Bathtubs and showers
- b.Sinks and lavatories✓
- c.Water closets and urinals
- d.Floor drains and floor sinks
Island venting is limited to sinks and lavatories; a residential kitchen sink with a dishwasher connection or disposer is included. Other fixtures are vented by the standard methods.IPC §916.1
An individual air admittance valve is installed under a kitchen sink. Under IPC §918.4, it must be located at least how far above the horizontal branch drain or fixture drain it vents?
- a.42 inches
- b.1 inch
- c.12 inches
- d.4 inches✓
Individual and branch-type air admittance valves are at least 4 inches above the horizontal branch drain or fixture drain being vented. Stack-type valves are at least 6 inches above the flood level rim of the highest fixture.IPC §918.4
A stack-type air admittance valve terminates a vent stack. Under IPC §918.4, it must be at least how far above the flood level rim of the highest fixture being vented?
- a.4 inches
- b.1 inch
- c.6 inches✓
- d.36 inches
Stack-type valves are set at least 6 inches above the flood level rim of the highest fixture vented; valves in attics sit at least 6 inches above insulation. Four inches is the figure for individual and branch-type valves above the drain.IPC §918.4
Under IPC §918.5, an air admittance valve must be installed:
- a.In the crawl space, below the level of the fixture trap
- b.In an accessible location with ventilation that lets air enter the valve✓
- c.In a sealed wall cavity where it is protected from tampering and from dust
- d.In a supply or return air plenum so that it is kept warm
The valve must be accessible for replacement and located in a ventilated space so that it can draw air. It may not be sealed in, placed in an air plenum, or installed below the drain it vents.IPC §§918.4, 918.5
Which statement about air admittance valves is correct under IPC §918?
- a.They may replace every vent to the outdoors in a one-story building
- b.They admit air on negative pressure but cannot relieve positive pressure✓
- c.They may be used to vent sewage ejector sumps of any capacity
- d.They relieve positive pressure but cannot admit air on negative pressure
An air admittance valve opens on negative pressure and closes by gravity, so it cannot vent positive pressure; that is why at least one vent must still extend outdoors. Sumps need open vents unless an engineered design is approved.IPC §918
A drainage stack serves 22 branch intervals. Under IPC §908.1, a relief vent between the drainage stack and the vent stack is required:
- a.At each tenth branch interval, counted from the top floor✓
- b.At each second branch interval, counted from the top floor
- c.At the base of the stack only, below the lowest branch
- d.At the roof only, where the two stacks join in a header
Stacks of more than 10 branch intervals have a relief vent at each tenth interval, starting from the top floor, to equalise pressure in tall stacks. A base connection alone does not relieve mid-height pressure zones.IPC §908.1
Under IPC §905.6, where a drain is roughed in for a future fixture, the vent provided for it must be at least:
- a.3 inches, whatever the size of the drain
- b.One-half the diameter of the roughed-in drain✓
- c.The same diameter as the roughed-in drain
- d.One-quarter the diameter of the roughed-in drain
A vent of at least half the diameter of the rough-in drain is installed and labelled or connected to the vent system. Quarter size is inadequate, and full size or 3 inches is not required.IPC §905.6
A "stack vent" is:
- a.A pipe that connects several vents and extends as one to the outdoor air
- b.The extension of a soil or waste stack above the highest horizontal drain connected to it✓
- c.A vent that also receives the discharge of fixtures other than water closets
- d.A vertical vent pipe installed alongside a drainage stack to circulate air to its branches
The stack vent is the dry extension of the drainage stack above the top branch. A separate vertical vent run with the stack is a vent stack, a vent that carries waste is a wet vent, and a pipe gathering several vents is a vent header.IPC §202
During the practical examination, candidates lay out a two-story DWV system. Under IPC §913.2, a waste stack vent (a stack that vents the fixtures connected to it) must be:
- a.Used only for water closets and urinals, with other fixtures separately vented
- b.Vertical, with no offsets between its lowest and highest fixture drain connections✓
- c.At least 6 inches in diameter, regardless of the fixture unit load that it carries
- d.Offset at each floor, so that waste from the floor above slows down on its way
A waste stack used as a vent must be vertical with no offsets between the lowest and highest fixture drain connection, and water closets and urinals may not discharge to it. Its size comes from the waste stack vent table, not a fixed 6 inches.IPC §913.2