40 questions

Water Supply and Distribution

Under IPC §603.1, the water service pipe to a building must be at least:

  • a.1-1/4 inches in diameter
  • b.3/4 inch in diameter✓
  • c.1 inch in diameter
  • d.1/2 inch in diameter

The water service is sized for the demand but is never smaller than 3/4 inch. Half an inch is a fixture supply size; 1 inch and larger are used where the load calls for it.IPC §603.1

Water Supply and Distribution

A water service and a building sewer are to be laid in separate trenches. Under IPC §603.2, they must be separated horizontally by at least:

  • a.25 feet of undisturbed or compacted earth
  • b.1 foot of undisturbed or compacted earth
  • c.10 feet of undisturbed or compacted earth
  • d.5 feet of undisturbed or compacted earth✓

The water service is kept 5 feet horizontally from the building sewer unless an exception applies, such as a water pipe on a shelf at least 12 inches above the sewer or sewer pipe of materials listed for use inside a building. The other distances are not the code figure.IPC §603.2

Water Supply and Distribution

Static water pressure at a house measures 95 psi. Under IPC §604.8, the plumber must install:

  • a.Nothing; pressure up to 125 psi is acceptable in a dwelling
  • b.A pressure-reducing valve, because pressure exceeds 80 psi✓
  • c.A water hammer arrester at the meter, with no regulator
  • d.A pressure booster pump, because pressure is under 100 psi

Where static pressure exceeds 80 psi, an approved pressure-reducing valve conforming to ASSE 1003 is required to bring it to 80 psi or less. A booster raises pressure, an arrester handles surges only, and 125 psi is not an accepted limit.IPC §604.8

Water Supply and Distribution

Under IPC §604.4, a shower head may deliver no more than:

  • a.5.0 gpm at 60 psi
  • b.3.5 gpm at 80 psi
  • c.2.5 gpm at 80 psi✓
  • d.1.0 gpm at 60 psi

The maximum flow rate table limits shower heads to 2.5 gallons per minute at 80 psi. The other rates are not the code maximum for a shower head.IPC §604.4

Water Supply and Distribution

A lavatory faucet in a public restroom (not a metering faucet) is limited by IPC §604.4 to:

  • a.0.5 gpm at 60 psi✓
  • b.1.5 gpm at 60 psi
  • c.2.2 gpm at 60 psi
  • d.2.5 gpm at 80 psi

Public lavatories are limited to 0.5 gpm at 60 psi; private lavatories and sink faucets are limited to 2.2 gpm at 60 psi, and 2.5 gpm at 80 psi is the shower head figure.IPC §604.4

Water Supply and Distribution

The maximum water consumption of a water closet under IPC §604.4 is:

  • a.1.6 gallons per flush✓
  • b.5.0 gallons per flush
  • c.3.5 gallons per flush
  • d.1.0 gallon per flush

Water closets are limited to 1.6 gallons per flushing cycle and urinals to 1.0 gallon. The 3.5- and 5-gallon closets are older designs that no longer comply.IPC §604.4

Water Supply and Distribution

Under IPC §604.5, the minimum fixture supply pipe size to a lavatory is:

  • a.3/8 inch✓
  • b.1/4 inch
  • c.1/2 inch
  • d.3/4 inch

Lavatories and tank-type water closets take a 3/8-inch minimum supply; bathtubs, showers, kitchen sinks and hose bibbs take 1/2 inch. One-quarter inch serves only items such as drinking fountains and ice makers.IPC §604.5

Water Supply and Distribution

Under IPC §604.5, the minimum fixture supply pipe size to a flushometer-valve water closet is:

  • a.3/4 inch
  • b.1 inch✓
  • c.1/2 inch
  • d.3/8 inch

A flushometer valve water closet needs a 1-inch supply because of its high momentary flow. A tank-type closet takes 3/8 inch, and 3/4 inch is the flushometer urinal size.IPC §604.5

Water Supply and Distribution

A plumber roughs in a hot and cold supply for a bathtub. Under IPC §604.5, each fixture supply must be at least:

  • a.1/2 inch✓
  • b.3/4 inch
  • c.3/8 inch
  • d.1/4 inch

Bathtubs take 1/2-inch minimum supplies. Three-eighths inch is the lavatory and tank-type water closet size, and 3/4 inch is not required for a standard tub.IPC §604.5

Water Supply and Distribution

Under IPC §604.9, a water hammer arrester installed to control pressure surges from a quick-closing valve must conform to:

  • a.ASSE 1013
  • b.ASSE 1016
  • c.ASSE 1070
  • d.ASSE 1010✓

Water hammer arresters conform to ASSE 1010 and are installed per the manufacturer's instructions where quick-closing valves are used. ASSE 1013 is a reduced pressure backflow assembly, 1016 a shower valve, and 1070 a temperature limiter.IPC §604.9

Water Supply and Distribution

Under IPC §605.3, water service pipe installed underground must have a working pressure rating of at least:

  • a.100 psi at 180°F
  • b.160 psi at 73°F✓
  • c.80 psi at 73°F
  • d.250 psi at 210°F

Water service pipe is rated at not less than 160 psi at 73.4°F. The 100 psi at 180°F rating applies to hot and cold water distribution pipe inside the building.IPC §605.3

Water Supply and Distribution

Hot water distribution tubing inside a building must, under IPC §605.4, be rated for at least:

  • a.50 psi at 120°F
  • b.80 psi at 140°F
  • c.160 psi at 73°F
  • d.100 psi at 180°F✓

Water distribution pipe and tubing have a minimum pressure rating of 100 psi at 180°F. The 160 psi at 73°F rating is for cold water service pipe.IPC §605.4

Water Supply and Distribution

Solder and flux used on potable water piping may contain, under IPC §605, no more than:

  • a.8.0 percent lead
  • b.2.0 percent lead
  • c.50 percent lead
  • d.0.2 percent lead✓

Solder and flux for potable water joints are limited to 0.2 percent lead; pipe and fittings are limited to a weighted average of 0.25 percent lead on wetted surfaces. The 50/50 tin-lead solder once common on water lines is prohibited.IPC §§605.2, 605.14

Water Supply and Distribution

Pipe, fittings and valves in contact with drinking water are "lead free" under IPC §605.2.1 where the weighted average lead content of wetted surfaces is not more than:

  • a.2.5 percent
  • b.8.0 percent
  • c.0.25 percent✓
  • d.0.05 percent

The limit is a weighted average of 0.25 percent lead on wetted surfaces. Eight percent was the pre-2014 federal figure; 0.2 percent applies to solder and flux.IPC §605.2.1

Water Supply and Distribution

Under IPC §606.2, where is an individual shutoff valve on the fixture supply NOT required in a dwelling?

  • a.At a bathtub or shower✓
  • b.At a lavatory
  • c.At a kitchen sink or bar sink
  • d.At a water closet

Shutoff valves are required on the supply to each fixture other than bathtubs and showers in one- and two-family residential occupancies. Water closets, lavatories and sinks each need a stop.IPC §606.2

Water Supply and Distribution

Under IPC §606.1, a full-open valve is required at each of these locations EXCEPT:

  • a.On the supply to each individual lavatory✓
  • b.On the water service at the building entrance
  • c.On the discharge side of the water meter
  • d.On the supply to each water heater

Full-open valves are required on the service at the building, on the discharge side of meters, on supplies to water heaters and tanks, and at risers in larger buildings. An individual fixture takes a shutoff valve under a different subsection, and it need not be full-open.IPC §§606.1, 606.2

Water Supply and Distribution

In the code definitions, "backsiphonage" is backflow caused by:

  • a.A water hammer surge from a quick-closing valve
  • b.Negative pressure in the potable supply piping✓
  • c.Thermal expansion in a closed water heater system
  • d.Higher pressure in the downstream system than in the supply

Backsiphonage is the backflow of contaminated water into the potable supply due to a negative or sub-atmospheric pressure in the supply pipe. Higher downstream pressure is backpressure backflow; thermal expansion and water hammer are pressure events, not definitions of backsiphonage.IPC §202

Water Supply and Distribution

Which method of backflow prevention gives the highest degree of protection and has no moving parts?

  • a.A dual check valve
  • b.A double check valve assembly
  • c.An air gap✓
  • d.An atmospheric vacuum breaker

An air gap is an unobstructed vertical distance through free atmosphere between the supply outlet and the flood rim; it cannot foul or wear. The mechanical devices all depend on checks or floats that can fail.IPC §§202, 608.14

Water Supply and Distribution

A 1/2-inch faucet spout discharges over a sink, away from any wall. Under IPC §608.15.1, the minimum air gap above the flood level rim is:

  • a.Twice the diameter of the effective opening: 1 inch✓
  • b.Six times the diameter of the effective opening: 3 inches
  • c.Four times the diameter of the effective opening: 2 inches
  • d.Equal to the diameter of the effective opening: 1/2 inch

The minimum air gap is two times the effective opening of the outlet, and more where the outlet is near walls. Two times 1/2 inch is 1 inch.IPC §608.15.1

Water Supply and Distribution

An atmospheric vacuum breaker is installed on the supply to a fixture. Under IPC §608.15.4, its critical level must be at least how far above the flood level rim of the fixture?

  • a.6 inches✓
  • b.1 inch
  • c.36 inches
  • d.12 inches

Atmospheric-type vacuum breakers are set with the critical level at least 6 inches above the flood level rim or highest downstream outlet. One inch is the fill valve figure for water closet tanks, and 12 inches applies to pressure vacuum breakers.IPC §608.15.4

Water Supply and Distribution

A pressure vacuum breaker assembly protects a lawn irrigation system. Under IPC §608.15.4, it must be installed at least how far above the highest sprinkler head or downstream pipe?

  • a.24 inches
  • b.12 inches✓
  • c.36 inches
  • d.6 inches

Pressure-type vacuum breakers are installed with the critical level at least 12 inches above all downstream piping and outlets. Six inches is the atmospheric vacuum breaker height.IPC §608.15.4

Water Supply and Distribution

Why may an atmospheric vacuum breaker not be installed with a shutoff valve downstream of it?

  • a.A downstream valve lowers the pressure below the fixture's need
  • b.A downstream valve raises the water temperature inside the body
  • c.Constant pressure holds the float closed and it can stick shut✓
  • d.Constant pressure makes the device discharge water all the time

An atmospheric vacuum breaker is for intermittent pressure only; with a valve downstream it sits under continuous pressure, and the air inlet float can stick in the closed position so it fails to open during backsiphonage. It does not discharge constantly or change pressure or temperature.IPC §608.15.4

Water Supply and Distribution

A sill cock on the outside of a house has a threaded outlet for a garden hose. Under IPC §608.15.4.2, the outlet must be protected by:

  • a.A relief valve piped to discharge on the ground
  • b.A pressure-reducing valve set at 25 psi or less at the sill cock
  • c.A vacuum breaker, such as a hose connection vacuum breaker✓
  • d.A full-port ball valve with a locking handle

Hose connections are protected by an atmospheric or pressure-type vacuum breaker or a permanently attached hose connection vacuum breaker, because a hose end left in a bucket or pool is a cross-connection. A regulator, relief valve or ball valve gives no backflow protection.IPC §608.15.4.2

Water Supply and Distribution

A lawn irrigation system injects fertiliser into the sprinkler piping. Under IPC §608.16.5, the potable supply must be protected by:

  • a.A reduced pressure principle backflow prevention assembly✓
  • b.An atmospheric vacuum breaker downstream of each zone valve
  • c.A double check valve assembly in a below-grade valve box
  • d.A single spring-loaded check valve at the water meter

Where chemicals are introduced into an irrigation system, a reduced pressure principle assembly is required. Vacuum breakers are accepted only for systems without chemical injection, and a double check or single check is not rated for a health hazard.IPC §608.16.5

Water Supply and Distribution

A hot water heating boiler containing chemical corrosion inhibitor is connected to the potable supply for make-up water. Under IPC §608.16.2, the connection is protected by:

  • a.A pressure-reducing fill valve with no added device
  • b.A reduced pressure principle backflow prevention assembly✓
  • c.A swing check valve and a gate valve installed in series
  • d.A backflow preventer with intermediate atmospheric vent

A boiler without chemicals may be protected by a backflow preventer with an intermediate atmospheric vent; where conditioning chemicals are added, a reduced pressure principle assembly or an air gap is required. Check valves and fill valves are not backflow preventers.IPC §608.16.2

Water Supply and Distribution

An automatic fire sprinkler system containing antifreeze is connected to the potable water supply. Under the IPC, the connection needs at least:

  • a.A single alarm check valve on the riser
  • b.A reduced pressure principle backflow prevention assembly✓
  • c.A double check backflow prevention assembly with test cocks
  • d.An atmospheric vacuum breaker on the riser

Sprinkler and standpipe systems are protected by a double check assembly at minimum; where the system contains chemical additives or antifreeze, a reduced pressure principle assembly is required. Vacuum breakers and an alarm check are not acceptable.IPC (2018) §608.17.4.1

Water Supply and Distribution

Which standard covers reduced pressure principle backflow prevention assemblies?

  • a.ASSE 1001
  • b.ASSE 1013✓
  • c.ASSE 1011
  • d.ASSE 1015

ASSE 1013 covers reduced pressure principle assemblies. ASSE 1001 is the atmospheric vacuum breaker, 1011 the hose connection vacuum breaker, and 1015 the double check valve assembly.IPC §608.13

Water Supply and Distribution

A carbonated beverage dispenser is connected to the water supply. Why does IPC §608.16.1 require a backflow preventer to ASSE 1022 and bar copper piping downstream of it?

  • a.Carbonated water is under vacuum and collapses copper tubing
  • b.Carbonated water leaves scale that blocks small copper tubing
  • c.Carbonated water is acidic and dissolves copper into the drink✓
  • d.Carbonated water is too cold for soldered copper joints to hold

Carbon dioxide in water forms carbonic acid, which leaches copper and can cause copper poisoning if it backs up into copper piping. The dispenser needs an ASSE 1022 backflow preventer, and piping downstream is not affected by CO2.IPC §608.16.1

Water Supply and Distribution

A reduced pressure principle assembly is to be installed. Under IPC §608.14.2, it may NOT be located:

  • a.Indoors above a floor drain sized to carry the relief discharge
  • b.In a pit or vault where the relief opening could be submerged✓
  • c.Outdoors above grade inside an insulated protective enclosure
  • d.In a mechanical room where it is accessible for yearly testing

The relief port must discharge to atmosphere through an air gap; in a pit subject to flooding the relief opening becomes a cross-connection. Indoor locations with drainage and protected above-grade enclosures are acceptable, and access for testing is required.IPC §§608.14.2, 608.15.2

Water Supply and Distribution

Nonpotable water piping in a building must be identified under IPC §608.9. Where reclaimed or rainwater is distributed, the pipe is colour-coded:

  • a.Purple✓
  • b.Green
  • c.Red
  • d.Yellow

Nonpotable water distribution piping such as reclaimed water, rainwater and gray water is purple and marked with a warning that the water is not for drinking. Yellow is associated with fuel gas marking and red with fire lines.IPC §608.9

Water Supply and Distribution

A new potable water system is disinfected under IPC §610 by filling it with a chlorine solution. Which combination satisfies the section?

  • a.50 parts per million held for 24 hours✓
  • b.5 parts per million held for 24 hours
  • c.10 parts per million held for 1 hour
  • d.50 parts per million held for 3 hours

The system is filled with a solution of at least 50 ppm chlorine for 24 hours, or 200 ppm for 3 hours, then flushed until the chlorine is purged and tested. Weaker or shorter combinations do not meet the section.IPC §610.1

Water Supply and Distribution

As an alternative to the 24-hour method, IPC §610 allows disinfection with a chlorine solution of at least 200 parts per million held for:

  • a.3 hours✓
  • b.30 minutes
  • c.12 hours
  • d.1 hour

The stronger 200 ppm solution stands in the system for 3 hours. Shorter contact times are not accepted, and 12 hours is longer than the alternative requires.IPC §610.1

Water Supply and Distribution

Under IPC §606.5, a pressure booster pump taking suction directly from the water service must have a low-pressure cutoff that stops the pump when suction pressure falls to:

  • a.2 psi
  • b.35 psi
  • c.10 psi✓
  • d.20 psi

A low-pressure cutoff prevents the booster from pulling the service below 10 psi and creating a vacuum in the main that could cause backsiphonage in neighbouring buildings. The other settings are not the code value.IPC §606.5.5

Water Supply and Distribution

A flexible braided connector supplies a lavatory faucet. Under IPC §604.5, the fixture supply may be reduced in size where the connector is no longer than:

  • a.12 inches
  • b.48 inches
  • c.30 inches✓
  • d.72 inches

The supply pipe extends to the floor or wall adjacent to the fixture, and a reduced-size flexible connector is allowed between it and the fixture where it is not more than 30 inches long. Longer small-bore connectors starve the fixture.IPC §604.5

Water Supply and Distribution

PVC water service pipe is joined with solvent cement. Under IPC §605, the joint surfaces must first be:

  • a.Roughened with a file and coated with flux
  • b.Heated with a torch until the pipe softens
  • c.Cleaned, dried and treated with a purple primer✓
  • d.Wrapped with thread seal tape for two turns

PVC pressure joints are made on clean, dry surfaces with a purple primer conforming to ASTM F656 followed by solvent cement to ASTM D2564, made while the cement is wet. Heat, flux and thread tape are for other materials.IPC §605 (PVC solvent cementing)

Water Supply and Distribution

A mechanically formed tee (a pulled branch outlet) is made in copper water tube. Under IPC §605, the branch joint must be:

  • a.Threaded
  • b.Brazed✓
  • c.Solvent cemented
  • d.Soldered

Mechanically formed tee fittings in copper tubing have a collar and a branch tube dimpled for depth control, and the joint is brazed. Soft solder is not accepted for these field-formed outlets.IPC §605 (mechanically formed tee fittings)

Water Supply and Distribution

Under IPC §608.7, a potable water outlet or stop-and-waste valve may be installed below grade only where it is:

  • a.A boiler drain installed at the lowest point of the water service
  • b.A hose bibb in a meter box that has a tight-fitting concrete cover
  • c.A drain cock that has been wrapped in polyethylene sheeting
  • d.A freezeproof yard hydrant or valve installed as the section allows✓

Potable water outlets and combination stop-and-waste valves are not installed underground or below grade, because the drain port can draw in ground water; freezeproof yard hydrants that drain the riser are allowed where the supply is protected and the hydrant is marked. A box cover or plastic wrap does not remove the hazard.IPC §608.7

Water Supply and Distribution

A water softener's drain line is run to a laundry standpipe. To protect the potable water system, the drain line must end:

  • a.In the vent pipe above the standpipe trap
  • b.Above the standpipe through an air gap✓
  • c.Inside the standpipe below the trap weir
  • d.In a tee solvent-welded into the standpipe

Water treatment units discharge through an air gap so sewage cannot be drawn back into the softener and the water supply. Any submerged or direct connection is a cross-connection, and waste never discharges into a vent.IPC §§608.1, 611

Water Supply and Distribution

Fixtures on the top floor of a building get weak flow when lower fixtures run. In sizing water piping under IPC §604, the pressure available at the highest fixture is reduced by static head at about:

  • a.0.433 psi for each foot of height✓
  • b.0.036 psi for each foot of height
  • c.2.31 psi for each foot of height
  • d.1.0 psi for each foot of height

A column of water 1 foot high exerts 0.433 psi, so each foot of elevation costs 0.433 psi (2.31 feet of head equals 1 psi). The 0.036 figure is psi per inch of water.IPC §604; Appendix E

Water Supply and Distribution

A yard hydrant line is connected to both a private well and the city water service through a normally closed gate valve. This arrangement is:

  • a.Acceptable, because the gate valve is kept closed when the well is in use
  • b.Acceptable, provided that the well water is tested for bacteria every year
  • c.Acceptable, provided that the gate valve has a lockable handle and a tag
  • d.A prohibited cross-connection between a private supply and the public system✓

Cross-connections between a private water supply and a potable public supply are prohibited; a valve is not backflow protection because it can leak or be opened. Testing and locks do not change that.IPC §608.6.2