300 questions

Plumbing Fixtures

Under IPC §413.1, a domestic food waste disposer connects to a drain of at least:

  • a.2 inches
  • b.1-1/4 inches
  • c.1-1/2 inches✓
  • d.3 inches

Domestic disposers connect to a drain not less than 1-1/2 inches in diameter; commercial units need at least 2 inches. An outlet of 1-1/4 inches is too small for ground food waste.IPC §413.1

Plumbing Fixtures

A whirlpool bathtub is installed with its circulation pump 3 feet from the access opening. Under IPC §421.5, the access opening must be at least:

  • a.18 inches by 18 inches✓
  • b.12 inches by 12 inches
  • c.24 inches by 30 inches
  • d.8 inches by 8 inches

A 12-by-12-inch opening is enough where the pump is within 2 feet of it; where the pump is farther than 2 feet, the opening is at least 18 by 18 inches. The other sizes are not the code dimensions.IPC (2018) §426.5

Plumbing Fixtures

Under IPC §403.3.3, required public toilet facilities in a building (other than a mall) must be within a travel distance of:

  • a.500 feet, and not more than one story above or below the space served✓
  • b.300 feet, and not more than two stories above or below the space
  • c.100 feet, and on the same story as the space that is being served
  • d.1,000 feet, and anywhere inside the building that is being served

Toilet facilities are located not more than one story above or below the space needing them, with a path of travel no longer than 500 feet. The other distances are not the general rule.IPC §403.3.3

Plumbing Fixtures

Under IPC §403.2, separate toilet facilities for each sex are NOT required in a mercantile occupancy (a shop) where the maximum occupant load is:

  • a.100 or fewer✓
  • b.150 or fewer
  • c.300 or fewer
  • d.200 or fewer

Separate facilities are not required in dwelling units, in structures with a total occupant load of 15 or fewer, or in mercantile occupancies with an occupant load of 100 or fewer. The larger loads are not exceptions in the section.IPC §403.2

Plumbing Fixtures

A flushometer valve is installed on a wall-hung urinal. Under IPC §425.2, the valve must be equipped with:

  • a.A swing check valve
  • b.A pressure-relief valve
  • c.A thermostatic mixing valve
  • d.An approved vacuum breaker✓

Flushometer valves and tanks have an approved vacuum breaker (backflow preventer) because the valve outlet sits below the fixture's flood rim. Relief, mixing and check valves do not protect against backsiphonage in this application.IPC §§425.2, 608.15.4

Plumbing Fixtures

An emergency eyewash station is installed in a plating shop. Under IPC §411, the station must be installed in accordance with:

  • a.ASSE 1016
  • b.ISEA Z358.1✓
  • c.NSF 61
  • d.ASME A112.19.2

Emergency showers and eyewash stations conform to and are installed under ISEA Z358.1; a drain is not required for them. ASSE 1016 covers shower valves, NSF 61 covers drinking water components, and A112.19.2 covers ceramic fixtures.IPC §411.1

Plumbing Fixtures

A domestic dishwasher drains to a kitchen sink tailpiece. Under IPC §802.1.6 (referenced from §409), the discharge hose must:

  • a.Run level along the cabinet floor and connect below the trap weir
  • b.Connect to the vent pipe above the flood rim of the kitchen sink
  • c.Rise and be secured to the underside of the counter before connecting✓
  • d.Drop into an open standpipe that is installed without a trap

The dishwasher waste line rises and is securely fastened to the underside of the sink rim or counter before connecting to a wye tailpiece or disposer, so sink waste cannot run back into the machine. A low level run, a vent connection or an untrapped standpipe would each be a violation.IPC §§409.2, 802.1.6

Plumbing Fixtures

Public hand-washing lavatories must be supplied with tempered water under IPC §416.5 through a device conforming to:

  • a.ASSE 1010
  • b.ASSE 1001
  • c.ASSE 1070✓
  • d.ASSE 1013

Tempered water at public lavatories is delivered through a temperature-limiting device to ASSE 1070 or the equivalent CSA standard. ASSE 1013 is a reduced pressure backflow assembly, 1010 a water hammer arrester, and 1001 an atmospheric vacuum breaker.IPC §416.5

Plumbing Fixtures

Under IPC §418, the waste outlet of a kitchen sink must be at least:

  • a.1-1/2 inches in diameter✓
  • b.2 inches in diameter
  • c.1-1/4 inches in diameter
  • d.2-1/2 inches in diameter

Sinks have waste outlets not less than 1-1/2 inches in diameter, with a strainer or crossbar to restrict the opening. The smaller size applies to lavatories; larger outlets are not required.IPC §418.2

Plumbing Fixtures

A water closet is set on a floor flange. Under IPC §405.4, the flange must be:

  • a.Set 1 inch below the finished floor and grouted to level
  • b.Glued to the finished floor tile with a silicone sealant
  • c.Left loose so that it can move with the closet bend below
  • d.Secured to the structure with corrosion-resistant fasteners✓

Floor-outlet fixtures connect to a flange fastened to the building structure with corrosion-resistant screws or bolts, and the closet is sealed to the flange with a gasket or setting compound. A loose or recessed flange lets the bowl rock and the seal fail.IPC §405.4

Water Heaters

A storage water heater's temperature and pressure relief valve is being selected. Under IPC §504.4, its pressure setting may not exceed the tank's working pressure or:

  • a.125 psi
  • b.150 psi✓
  • c.100 psi
  • d.200 psi

Relief valves are set to open at not more than 150 psi or the maximum working pressure of the heater, whichever is less, and at not more than 210°F. The other pressures are not the code ceiling.IPC §504.4

Water Heaters

The temperature setting of a water heater's combination relief valve may not exceed:

  • a.180°F
  • b.212°F
  • c.250°F
  • d.210°F✓

The temperature relief setting is limited to 210°F, just under the atmospheric boiling point, so that the valve opens before water in the tank can flash to steam. A 180°F setting would nuisance-trip some systems, and 212°F and above is too late.IPC §504.4

Water Heaters

Which installation of a relief valve discharge pipe violates IPC §504.6?

  • a.A discharge pipe that drains by gravity to the pan
  • b.A discharge pipe with a shutoff valve installed in it✓
  • c.A discharge pipe the same size as the relief valve outlet
  • d.A discharge pipe ending 4 inches above the floor

No valve may be installed in the relief discharge line, because a closed valve would turn the tank into a pressure vessel with no relief. A full-size pipe, gravity drainage and termination within 6 inches of the floor are all what the code requires.IPC §504.6

Water Heaters

The outlet end of a relief valve discharge pipe must terminate, under IPC §504.6, not more than how far above the floor or waste receptor?

  • a.6 inches✓
  • b.24 inches
  • c.12 inches
  • d.2 inches

The pipe ends not more than 6 inches above the floor or flood level rim of the receptor, and not less than two pipe diameters above it, so that hot water is not sprayed at face height and an air gap remains. Twelve and 24 inches allow scalding spray.IPC §504.6

Water Heaters

Why may the end of a relief valve discharge pipe not be threaded under IPC §504.6?

  • a.A threaded end corrodes faster in hot water than a plain end
  • b.A threaded end invites someone to cap or plug the pipe✓
  • c.A threaded end restricts flow more than a plain end does
  • d.A threaded end cannot be seen clearly by the inspector

The end is left unthreaded so that nobody can screw on a cap or plug to stop a drip, which would disable the relief valve. Flow restriction, corrosion and visibility are not the reason for the rule.IPC §504.6

Water Heaters

Two water heaters stand side by side. Under IPC §504.6, their relief valve discharge pipes:

  • a.Must each run separately; a discharge pipe serves one relief device✓
  • b.Must be joined so that only one termination point has to be watched
  • c.May be joined with a tee if the common pipe is increased one size
  • d.May be joined with a wye if a check valve is fitted in each branch

The discharge piping serves a single relief device and does not connect to piping serving any other relief device or equipment. Tees, wyes and check valves in the line are prohibited.IPC §504.6

Water Heaters

A water heater is installed in an attic where a leak would cause damage. Under IPC §504.7 it must sit in a pan with a drain of at least:

  • a.3/4 inch✓
  • b.1 inch
  • c.1/2 inch
  • d.1-1/4 inches

The pan is at least 1-1/2 inches deep and is drained by an indirect waste pipe of not less than 3/4 inch. Half an inch is too small; the larger sizes are not required.IPC §504.7.1

Water Heaters

Under IPC §504.7, a galvanized steel water heater pan must be at least what thickness?

  • a.0.0100 inch (No. 32 gage)
  • b.0.0575 inch (No. 16 gage)
  • c.0.1250 inch (No. 11 gage)
  • d.0.0236 inch (No. 24 gage)✓

Galvanized steel and aluminium pans are at least 0.0236 inch thick (No. 24 gage). The No. 16 gage figure belongs to nail shield plates, and the others are not pan requirements.IPC §504.7

Water Heaters

A water heater pan drain is run to the outside of the building. Under IPC §504.7.2, it must terminate above the adjacent ground at a height of:

  • a.At least 24 inches and not more than 48 inches
  • b.At least 6 inches and not more than 24 inches✓
  • c.At least 36 inches and not more than 72 inches
  • d.At least 1 inch and not more than 6 inches

The pan drain extends full size to an indirect waste receptor or to the exterior, ending 6 to 24 inches above the ground surface. Lower outlets can be buried or blocked, and higher ones discharge at a height that goes unnoticed or splashes.IPC §504.7.2

Water Heaters

A gas water heater with a standing pilot is placed in a residential garage. Under IPC §502.1.1 and IFGC §305.3, its ignition source must be at least how far above the garage floor, unless the heater is listed as flammable vapour ignition resistant?

  • a.6 inches
  • b.12 inches
  • c.18 inches✓
  • d.36 inches

Appliances with an ignition source in a garage are elevated so the source is at least 18 inches above the floor, because gasoline vapour collects low. FVIR-listed heaters are excepted. The other heights are not the code figure.IFGC §305.3

Water Heaters

A water heater in an attic must be reached by a passageway. Under IPC §502.3, the passageway may be no longer than:

  • a.50 feet, measured along its centreline from the opening to the heater
  • b.10 feet, measured along its centreline from the opening to the heater
  • c.20 feet, measured along its centreline from the opening to the heater✓
  • d.100 feet, measured along its centreline from the opening to the heater

The attic passageway is at least 30 inches high and 22 inches wide and not more than 20 feet long, with continuous solid flooring at least 24 inches wide. The other lengths are not the code limit.IPC §502.3

Water Heaters

Under IPC §502.3, the level service space in front of an attic water heater's service side must be at least:

  • a.48 inches by 48 inches
  • b.30 inches by 30 inches✓
  • c.18 inches by 18 inches
  • d.24 inches by 24 inches

A level service space of at least 30 inches deep and 30 inches wide is required at the front or service side. Smaller spaces do not let a plumber work safely; 48 inches is more than required.IPC §502.3

Water Heaters

IPC §503.1 requires what on the cold water supply to each water heater?

  • a.A shutoff valve✓
  • b.A strainer
  • c.A backflow preventer
  • d.A pressure gauge

A valve is installed on the cold water branch to each hot water storage tank or water heater so that it can be isolated for service. Backflow preventers, gauges and strainers are not required at every heater.IPC §§503.1, 606.1

Water Heaters

A water heater is fed from the bottom, and the supply piping could siphon the tank dry. Under IPC §504.1, the heater must be protected by:

  • a.A thermal expansion tank
  • b.A pressure-reducing valve
  • c.A second relief valve
  • d.A vacuum relief valve✓

Bottom-fed heaters and heaters above the fixtures they serve are fitted with a vacuum relief valve so that the tank cannot be siphoned empty and fired dry or collapsed. Pressure regulators, a second T&P valve and expansion tanks address pressure, not siphonage.IPC §504.1

Water Heaters

A check valve on the cold water service creates a closed system at a storage water heater. Under IPC §607.3, the plumber must install:

  • a.A device to control thermal expansion, such as an expansion tank✓
  • b.A bypass around the check valve that is left open during heating
  • c.A second relief valve set 25 psi lower than the first relief valve
  • d.A larger water heater drain valve piped to the outside of the house

Where a backflow preventer, check valve or pressure regulator prevents expanding water from moving back to the main, a thermal expansion control device is required. A relief valve is a safety device, not an operating control, and a bypass would defeat the check valve.IPC §607.3

Water Heaters

A water heater also supplies a hydronic space-heating coil at 160°F. Under IPC §501.2, the potable hot water sent to fixtures must:

  • a.Be delivered at 160°F so that the heating coil is not short of heat
  • b.Be cooled in an uninsulated loop of pipe before it reaches fixtures
  • c.Be tempered to 140°F or less by a master thermostatic mixing valve✓
  • d.Be separated from the coil by a reduced pressure backflow assembly

Where a combination system needs water above 140°F, a master thermostatic mixing valve to ASSE 1017 limits the water supplied to the potable distribution system to 140°F or less. Sending 160°F water to fixtures scalds, and a backflow assembly or a cooling loop does not control temperature.IPC §501.2

Water Heaters

Under IPC §607.2, the developed length of hot water piping from the source of hot water to a fixture may not exceed:

  • a.150 feet
  • b.25 feet
  • c.50 feet✓
  • d.100 feet

Hot or tempered water supply to fixtures is limited to 50 feet of developed length from the heater, or from a recirculating or heat-traced line, so that users do not run water to waste while waiting. The other lengths are not the code limit.IPC §607.2

Water Heaters

Looking at a lavatory faucet from the front, IPC §607.4 requires the hot water to be controlled from:

  • a.The centre only
  • b.The left side✓
  • c.Either side, if labelled
  • d.The right side

Fixture fittings and faucets supplied with both hot and cold water are installed so that hot corresponds to the left side. Labels do not excuse reversed supplies, because users rely on the convention to avoid scalding.IPC §607.4

Water Heaters

Under IPC §505.1, an unfired hot water storage tank must be insulated to at least:

  • a.R-3.0
  • b.R-6.25
  • c.R-30.5
  • d.R-12.5✓

Unfired hot water storage tanks are insulated to a minimum of R-12.5. The lower values are typical of pipe insulation and R-30 is a ceiling insulation figure.IPC §505.1

Water Heaters

A gas water heater is to be installed in a bedroom closet. Under IFGC §303.3, this is permitted only where the heater is:

  • a.Direct-vent, or in a sealed enclosure taking all combustion air from outdoors✓
  • b.Fitted with a draft hood and a single-wall vent connector to a chimney
  • c.Rated at 40,000 Btu/h or less and fitted with an automatic vent damper
  • d.Raised 18 inches above the floor and fitted with a drain pan and a pan drain

Fuel-burning appliances may not be in sleeping rooms, bathrooms or their closets unless they are direct-vent, or are in an enclosure with a weather-stripped self-closing door that draws all combustion air from outdoors. Input rating, elevation and a draft hood do not make the location acceptable.IFGC §303.3

Water Heaters

A gas water heater takes its combustion air from the room it stands in. Under the standard method of IFGC §304.5.1, the room must have a volume of at least:

  • a.25 cubic feet per 1,000 Btu/h of input
  • b.100 cubic feet per 1,000 Btu/h of input
  • c.50 cubic feet per 1,000 Btu/h of input✓
  • d.10 cubic feet per 1,000 Btu/h of input

The standard method requires 50 cubic feet of room volume for each 1,000 Btu/h of total appliance input. A space with less volume needs openings to other rooms or to the outdoors.IFGC §304.5.1

Water Heaters

A 40,000 Btu/h gas water heater is in a closet that draws combustion air through two openings direct to the outdoors. Under IFGC §304.6.1, each opening needs a free area of at least:

  • a.10 square inches (1 sq in per 4,000 Btu/h)✓
  • b.4 square inches (1 sq in per 10,000 Btu/h)
  • c.20 square inches (1 sq in per 2,000 Btu/h)
  • d.40 square inches (1 sq in per 1,000 Btu/h)

Openings that communicate directly with the outdoors, or through vertical ducts, need 1 square inch per 4,000 Btu/h each: 40,000 ÷ 4,000 = 10. The 2,000 figure is for horizontal ducts and the 1,000 figure is for openings to other indoor spaces.IFGC §304.6.1

Water Heaters

The vent connector from a draft-hood water heater must slope upward toward the vent, under IFGC §503.10.7, at least:

  • a.1 inch per foot
  • b.1/4 inch per foot✓
  • c.1/16 inch per foot
  • d.1/8 inch per foot

Vent connectors rise at least 1/4 inch per foot with no dips or sags, so that hot flue gases flow to the vent and condensate does not pool. Flatter runs spill at the draft hood.IFGC §503.10.7

Water Heaters

A single-wall metal vent connector from a water heater runs past a wood joist. Unless the appliance listing says otherwise, IFGC Table 503.10.5 calls for a clearance to combustibles of:

  • a.6 inches✓
  • b.3 inches
  • c.1 inch
  • d.18 inches

Single-wall connectors serving listed draft-hood appliances need 6 inches of clearance; listed Type B vent material needs the clearance in its listing, typically 1 inch. Eighteen inches applies to some unlisted appliances.IFGC §503.10.5

Water Heaters

Under IFGC §408.4, a sediment trap at a gas water heater is installed:

  • a.Upstream of the gas meter, on the utility's side of the service line to the house
  • b.Downstream of the shutoff valve, as close to the appliance inlet as practical✓
  • c.On the cold water inlet, to keep scale out of the heater's dip tube
  • d.At the vent connector, to collect condensate from the draft hood

The sediment trap is a tee with a capped nipple in the bottom opening, placed after the appliance shutoff valve and as close to the inlet as practical, to catch debris and condensate in the gas line. It has nothing to do with the vent or the water piping.IFGC §408.4

Water Heaters

The gas shutoff valve for a water heater must be located, under IFGC §409.5.1:

  • a.At the gas meter, with no valve required at the heater
  • b.In an adjacent room and within 15 feet of the heater
  • c.Above the draft hood so that it stays clear of the pan
  • d.In the same room as the heater and within 6 feet of it✓

Each appliance has a shutoff valve in the same room, within 6 feet, upstream of the connector, and accessible. The meter valve does not substitute, and a valve in another room cannot be reached quickly.IFGC §409.5.1

Water Heaters

Under IPC §501.3, every storage water heater must have a drain valve that:

  • a.Is installed at the top of the tank on the hot water outlet pipe
  • b.Is piped full size directly into the building's sanitary drain
  • c.Is installed at the bottom of the tank so the tank can be emptied✓
  • d.Is sealed by the inspector after the final plumbing inspection

A drain valve at the bottom of each tank-type heater and storage tank allows the tank to be emptied and flushed. A top connection cannot drain the tank, a direct sewer connection is a cross-connection, and the valve is not sealed.IPC §501.3

Water Heaters

The relieving capacity of a water heater's relief valve, under IPC §504.5, must be:

  • a.Matched to the size of the tank drain valve only
  • b.Matched to the size of the cold water supply pipe
  • c.Half of the heat input of the water heater or more
  • d.Not less than the heat input of the water heater✓

The valve's rated capacity in Btu/h must at least equal the heater's input, so that it can discharge energy as fast as the burner or element adds it. Pipe and drain valve sizes are not the basis for rating.IPC §504.5

Water Heaters

Where may a relief valve discharge pipe from a water heater terminate under IPC §504.6?

  • a.To the floor, the heater pan, a waste receptor or the outdoors✓
  • b.Into the vent connector, above the draft hood of the heater
  • c.Directly into the building drain, through a sealed fitting
  • d.Into the cold water supply, upstream of the shutoff valve

The discharge goes through an air gap in the same room to the floor, to the pan, to a waste receptor or to the outdoors, where it can be seen. It may not be connected directly to the drainage system or to any other piping.IPC §504.6

Water Heaters

An instructor shows a water heater whose relief discharge pipe runs upward from the valve, then down to the floor. This violates IPC §504.6 because the pipe:

  • a.Is the wrong colour, because relief discharge piping must be painted red
  • b.Is too long, because discharge piping may not be over 2 feet in total length
  • c.Is trapped, so water stands against the valve and it may freeze or corrode shut✓
  • d.Is unvented, because discharge piping needs a vent ahead of each elbow

Discharge piping must drain by gravity and may not be trapped; an upward loop holds water that hides a leaking valve and can freeze or scale. The code sets no 2-foot limit, colour or vent requirement.IPC §504.6

Water Supply and Distribution

Under IPC §603.1, the water service pipe to a building must be at least:

  • a.1-1/4 inches in diameter
  • b.3/4 inch in diameter✓
  • c.1 inch in diameter
  • d.1/2 inch in diameter

The water service is sized for the demand but is never smaller than 3/4 inch. Half an inch is a fixture supply size; 1 inch and larger are used where the load calls for it.IPC §603.1

Water Supply and Distribution

A water service and a building sewer are to be laid in separate trenches. Under IPC §603.2, they must be separated horizontally by at least:

  • a.25 feet of undisturbed or compacted earth
  • b.1 foot of undisturbed or compacted earth
  • c.10 feet of undisturbed or compacted earth
  • d.5 feet of undisturbed or compacted earth✓

The water service is kept 5 feet horizontally from the building sewer unless an exception applies, such as a water pipe on a shelf at least 12 inches above the sewer or sewer pipe of materials listed for use inside a building. The other distances are not the code figure.IPC §603.2

Water Supply and Distribution

Static water pressure at a house measures 95 psi. Under IPC §604.8, the plumber must install:

  • a.Nothing; pressure up to 125 psi is acceptable in a dwelling
  • b.A pressure-reducing valve, because pressure exceeds 80 psi✓
  • c.A water hammer arrester at the meter, with no regulator
  • d.A pressure booster pump, because pressure is under 100 psi

Where static pressure exceeds 80 psi, an approved pressure-reducing valve conforming to ASSE 1003 is required to bring it to 80 psi or less. A booster raises pressure, an arrester handles surges only, and 125 psi is not an accepted limit.IPC §604.8

Water Supply and Distribution

Under IPC §604.4, a shower head may deliver no more than:

  • a.5.0 gpm at 60 psi
  • b.3.5 gpm at 80 psi
  • c.2.5 gpm at 80 psi✓
  • d.1.0 gpm at 60 psi

The maximum flow rate table limits shower heads to 2.5 gallons per minute at 80 psi. The other rates are not the code maximum for a shower head.IPC §604.4

Water Supply and Distribution

A lavatory faucet in a public restroom (not a metering faucet) is limited by IPC §604.4 to:

  • a.0.5 gpm at 60 psi✓
  • b.1.5 gpm at 60 psi
  • c.2.2 gpm at 60 psi
  • d.2.5 gpm at 80 psi

Public lavatories are limited to 0.5 gpm at 60 psi; private lavatories and sink faucets are limited to 2.2 gpm at 60 psi, and 2.5 gpm at 80 psi is the shower head figure.IPC §604.4

Water Supply and Distribution

The maximum water consumption of a water closet under IPC §604.4 is:

  • a.1.6 gallons per flush✓
  • b.5.0 gallons per flush
  • c.3.5 gallons per flush
  • d.1.0 gallon per flush

Water closets are limited to 1.6 gallons per flushing cycle and urinals to 1.0 gallon. The 3.5- and 5-gallon closets are older designs that no longer comply.IPC §604.4

Water Supply and Distribution

Under IPC §604.5, the minimum fixture supply pipe size to a lavatory is:

  • a.3/8 inch✓
  • b.1/4 inch
  • c.1/2 inch
  • d.3/4 inch

Lavatories and tank-type water closets take a 3/8-inch minimum supply; bathtubs, showers, kitchen sinks and hose bibbs take 1/2 inch. One-quarter inch serves only items such as drinking fountains and ice makers.IPC §604.5

Water Supply and Distribution

Under IPC §604.5, the minimum fixture supply pipe size to a flushometer-valve water closet is:

  • a.3/4 inch
  • b.1 inch✓
  • c.1/2 inch
  • d.3/8 inch

A flushometer valve water closet needs a 1-inch supply because of its high momentary flow. A tank-type closet takes 3/8 inch, and 3/4 inch is the flushometer urinal size.IPC §604.5

Water Supply and Distribution

A plumber roughs in a hot and cold supply for a bathtub. Under IPC §604.5, each fixture supply must be at least:

  • a.1/2 inch✓
  • b.3/4 inch
  • c.3/8 inch
  • d.1/4 inch

Bathtubs take 1/2-inch minimum supplies. Three-eighths inch is the lavatory and tank-type water closet size, and 3/4 inch is not required for a standard tub.IPC §604.5

Water Supply and Distribution

Under IPC §604.9, a water hammer arrester installed to control pressure surges from a quick-closing valve must conform to:

  • a.ASSE 1013
  • b.ASSE 1016
  • c.ASSE 1070
  • d.ASSE 1010✓

Water hammer arresters conform to ASSE 1010 and are installed per the manufacturer's instructions where quick-closing valves are used. ASSE 1013 is a reduced pressure backflow assembly, 1016 a shower valve, and 1070 a temperature limiter.IPC §604.9