Texas Journeyman Plumber Exam — All Questions
300 questions
A sewage ejector serves a water closet in a basement. Under IPC §712.4.2, the ejector discharge pipe must be at least:
- a.3/4 inch
- b.2 inches✓
- c.1-1/4 inches
- d.4 inches
The discharge from a sewage pump or ejector that handles solids is at least 2 inches (grinder pumps and macerating toilet systems are treated separately and may use smaller pipe per their listing). Four inches is not required.IPC §712.4.2
A basement floor drain is lower than the cover of the next upstream manhole in the public sewer. Under IPC §714.1, the drain must be protected by:
- a.A pressure vacuum breaker
- b.A trap primer
- c.A running trap
- d.A backwater valve✓
Fixtures with flood level rims below the elevation of the next upstream manhole cover are protected by a backwater valve, which closes when the sewer surcharges. Vacuum breakers are water supply devices, and trap primers and running traps do not stop reverse flow.IPC §714.1
A two-story house has a backwater valve protecting the basement fixtures. Under IPC §714.1, the fixtures on the upper floors, which are above the manhole cover elevation:
- a.Must each have a backwater valve of their own
- b.Must also discharge through the backwater valve
- c.Must not discharge through the backwater valve✓
- d.Must discharge through a separate building sewer
Fixtures above the manhole cover elevation may not drain through the backwater valve, because when the valve closes their discharge would flood the basement. They need no backwater valve and no separate sewer; they connect downstream of the valve.IPC §714.1
Which joint in drainage piping is prohibited by IPC §707.1?
- a.A shielded hubless coupling
- b.A saddle-type fitting✓
- c.A compression gasket joint
- d.A solvent-cemented PVC joint
Prohibited joints include cement or concrete joints, mastic or hot-pour bituminous joints, saddle-type fittings and solvent-cement joints between different types of plastic pipe. Solvent-cemented PVC, shielded couplings and compression gaskets are all approved methods.IPC §707.1
A PVC building drain must be connected to an existing ABS building sewer. Under IPC §705, the two plastics are joined with:
- a.An approved mechanical transition coupling or adapter✓
- b.A bead of silicone sealant inside a PVC slip coupling
- c.ABS solvent cement that is applied to both pipe ends
- d.PVC solvent cement that is applied to both pipe ends
Different plastics are joined with approved adapter or transition fittings, such as a shielded elastomeric coupling. Ordinary solvent cement joints between different plastics are prohibited, and sealant is not a joint method.IPC §§705.16, 707.1
Under IPC §705, a solvent-cemented joint in PVC drain pipe may be made without primer only where:
- a.The joint is tested with air at 5 psi before the cement has set
- b.The air temperature at the time the joint is made is above 90°F
- c.The cement is certified for it and the DWV pipe is 4 inches or smaller, non-pressure✓
- d.The pipe is larger than 6 inches and the joint will be buried under a concrete slab
The 2018 code allows primerless joints only for non-pressure DWV pipe 4 inches and smaller using a third-party certified cement that conforms to ASTM D2564. Size over 6 inches, heat and testing do not waive primer.IPC §705.11.2
Hubless cast-iron soil pipe is joined with:
- a.A solvent cement made for joining cast iron to plastic pipe
- b.Threaded ends cut on the job with a standard pipe die
- c.Molten lead poured over packed oakum in the bell end of each length of pipe
- d.A shielded elastomeric sleeve coupling tightened to the specified torque✓
Hubless pipe has no bell; it is joined with an elastomeric sealing sleeve and a stainless-steel shield and clamps conforming to the referenced standards. Lead and oakum is for hub-and-spigot pipe, and cast-iron soil pipe is not threaded or cemented.IPC §705 (cast iron mechanical joints)
Under IPC §701.2, a building in which plumbing fixtures are installed must connect to a public sewer where:
- a.The building is more than one story high
- b.The owner chooses a sewer over a septic system
- c.A public sewer is available to the premises✓
- d.The building has more than two bathrooms
Buildings with plumbing fixtures connect to a public sewer where one is available; otherwise an approved private sewage disposal system is used. Owner preference, fixture count and height do not decide it.IPC §701.2
The extension of drain piping more than 2 feet past the last connection, with no fixture on it, is a "dead end". Under IPC §704.5, dead ends are:
- a.Permitted, where the dead end is capped and an air admittance valve is fitted
- b.Prohibited, except where needed to extend a cleanout to an accessible point✓
- c.Prohibited, except where the dead end is larger than the drain that it joins
- d.Permitted, where the dead end slopes at 1/4 inch per foot back to the drain
Dead ends collect solids and are prohibited; the only allowance is a cleanout extension brought to an accessible location. Slope, a cap or a larger size does not make a dead end acceptable.IPC §704.5
In the code definitions, the "building drain" ends and the "building sewer" begins:
- a.10 feet outside the building wall
- b.At the inside face of the building wall
- c.At the property line of the lot
- d.30 inches outside the building wall✓
The building drain is the lowest piping that receives the discharge of the drainage system and extends 30 inches beyond the exterior walls, where the building sewer begins. The other points are not the code's dividing line.IPC §202
A "branch interval" on a drainage stack is defined in IPC §202 as a vertical length of stack of at least:
- a.8 feet, within which the horizontal branches of one story connect✓
- b.12 feet, within which the horizontal branches of two stories connect
- c.4 feet, within which the horizontal branches of one story connect
- d.20 feet, within which the horizontal branches of two stories connect
The 2018 IPC defines a branch interval as a vertical distance of 8 feet or more in developed length between the connections of horizontal branches to a drainage stack, measured down from the highest branch connection; in practice it corresponds to a story. It is used to size stacks and decide when a vent stack is needed.IPC (2018) §202
A "stack" in the drainage system is:
- a.A fitting that joins the fixture drain to the trap and maintains the seal of water in the trap
- b.A general term for any vertical line of soil, waste or vent piping extending through at least one story✓
- c.A horizontal pipe that carries the discharge of two or more fixture branches to the building drain
- d.The part of the drainage system that extends from the building wall to the public sewer main
A stack is any main vertical DWV line extending through one or more stories. The horizontal collector is a branch, the piping outside the wall is the building sewer, and the last choice describes no code term.IPC §202
A horizontal branch connects to the base of a tall drainage stack. Under IPC §704.3, a horizontal branch may not connect to the building drain within how far downstream of the stack?
- a.10 pipe diameters✓
- b.40 pipe diameters
- c.5 pipe diameters
- d.2 pipe diameters
Horizontal branches connect to the horizontal drain at least 10 pipe diameters downstream from the base of a stack, clear of the turbulent hydraulic jump zone. The smaller distances fall inside that zone.IPC §704.3
A plumber sets a closet flange on a 4-by-3-inch closet bend that connects to a 3-inch drain. Under IPC §704.2, this arrangement is:
- a.Acceptable; a 4-by-3 closet bend is not considered a reduction in size✓
- b.Acceptable only if the water closet is a pressure-assisted model
- c.A violation unless a cleanout is installed at the closet bend
- d.A violation; the drain must be 4 inches all the way from the flange
The code states that a 4-inch by 3-inch water closet connection is not a reduction in size. A 3-inch drain is adequate for a water closet, and no special closet type or cleanout is needed.IPC §704.2
Why is excessive slope, as well as too little slope, a problem on a small horizontal drain?
- a.The vent piping fills with waste and loses its air passage
- b.The pipe wall wears through quickly from the speed of the waste stream
- c.The liquid can outrun the solids and leave them behind in the pipe✓
- d.The trap seals upstream are pushed out through the fixtures
Drains are designed to flow partly full at a scouring velocity; on a very steep small line, water can run ahead of solids and strand them. Wall wear and blown traps are not the usual result of slope alone.IPC §704.1
IPC §901.2.1 requires the venting system to protect trap seals so that no trap is subjected to a pressure differential of more than:
- a.2 inches of water column
- b.4 inches of water column
- c.1/4 inch of water column
- d.1 inch of water column✓
The vent system is designed so that pneumatic pressure differences at trap seals do not exceed 1 inch of water column. A 2-inch trap seal survives that; larger differentials siphon or blow the seal.IPC §901.2.1
Under IPC §909.1, the developed length of a 1-1/2-inch fixture drain from the trap weir to the vent fitting may not exceed:
- a.6 feet✓
- b.5 feet
- c.3 feet 6 inches
- d.8 feet
The trap-to-vent table allows 5 feet for a 1-1/4-inch trap, 6 feet for 1-1/2 inch, 8 feet for 2 inch, 12 feet for 3 inch and 16 feet for 4 inch. The 3 feet 6 inches figure comes from a different model code.IPC §909.1
A 2-inch trap serves a shower. Under IPC §909.1, the trap arm may be no longer than:
- a.8 feet✓
- b.12 feet
- c.5 feet
- d.6 feet
A 2-inch fixture drain sloped at 1/4 inch per foot may run 8 feet from trap weir to vent. Five and 6 feet apply to 1-1/4 and 1-1/2 inch traps, and 12 feet to 3-inch traps.IPC §909.1
Under IPC §909.2, the total fall of a fixture drain between the trap weir and the vent connection may not exceed:
- a.Two pipe diameters
- b.One-half pipe diameter
- c.One pipe diameter✓
- d.Four pipe diameters
If the trap arm drops more than its own diameter, the vent opening ends up below the trap weir and the arm acts like an S-trap that siphons itself. Water closets are excepted from the limit.IPC §909.2
A vent is connected to a fixture drain right at the top of the trap bend. Under IPC §909.3 this "crown vent" is prohibited because the vent connects within how far of the trap weir?
- a.Six pipe diameters
- b.Four pipe diameters
- c.Two pipe diameters✓
- d.Ten pipe diameters
A vent may not be installed within two pipe diameters of the trap weir. A vent that close clogs with debris thrown up by the flow and speeds evaporation of the seal.IPC §909.3
Under IPC §906.2, an individual vent must be at least one-half the diameter of the drain it serves, and in no case smaller than:
- a.2-1/2 inches
- b.1 inch
- c.1-1/4 inches✓
- d.1-1/2 inches
Vents other than stack vents and vent stacks are at least half the required diameter of the drain served and not less than 1-1/4 inches. Smaller pipe clogs and frosts; 2 inches is not a universal minimum.IPC §906.2
A 3-inch drain is served by an individual vent that is 55 feet in developed length. Under IPC §906.2, the vent must be at least:
- a.2 inches: one-half the drain size, increased one pipe size for length over 40 feet✓
- b.1-1/4 inches: the minimum size that the code accepts for any individual vent
- c.1-1/2 inches: one-half the drain size, with no increase required for its length
- d.3 inches: the same size as the drain, for any vent of more than 40 feet in length
Half of 3 inches is 1-1/2 inches; vents exceeding 40 feet in developed length are increased one nominal pipe size for the full length, giving 2 inches. Matching the drain size is not required.IPC §906.2
Under IPC §905.4, a dry vent must rise vertically to at least what height before it may run horizontally?
- a.36 inches above the finished floor of the room
- b.2 inches above the trap weir of the fixture served
- c.12 inches below the flood level rim of the fixture served
- d.6 inches above the flood level rim of the fixture served✓
Every dry vent rises vertically to a point at least 6 inches above the flood level rim of the highest trap or fixture being vented before offsetting, so that a stoppage cannot turn the vent into a drain. Height above the floor or trap weir is not the measure.IPC §905.4
Under IPC §905.3, where a vent connects to a horizontal drain, the vent pipe must take off:
- a.From the bottom of the drain pipe
- b.Above the centreline of the drain pipe✓
- c.Below the centreline of the drain pipe
- d.Level with the invert of the drain
Vents connect above the horizontal centreline of the drain so that waste does not flow into and block the vent. Connections at or below the centreline fill with solids.IPC §905.3
Vent pipes must be sloped and connected, under IPC §905.2, so that they:
- a.Fall away from the drain toward the roof
- b.Stay level between the drain and the stack
- c.Hold a seal of water at each change of direction
- d.Drain back to the drainage pipe by gravity✓
Vent and branch vent pipes are graded so that condensation and rainwater drain back to the drainage system by gravity. A vent that holds water is blocked to air flow.IPC §905.2
Under IPC §903.5, an open vent terminal may not be within 10 feet horizontally of a window or air intake unless it is at least how far above the top of the opening?
- a.10 feet
- b.3 feet✓
- c.1 foot
- d.6 feet
A vent terminal is not located directly beneath a door, window or air intake, nor within 10 feet horizontally of one unless it is at least 3 feet above the top of the opening. One foot is too little to keep sewer gas out.IPC §903.5
A vent terminates through a roof that is used as a sun deck. Under IPC §903.1, the vent must extend above the roof at least:
- a.6 inches
- b.7 feet✓
- c.2 feet
- d.10 feet
Where a roof is used for any purpose other than weather protection, such as a deck or promenade, vents extend at least 7 feet above it so gases discharge above head height. Ordinary roofs use the locally set height.IPC §903.1
In a cold-climate jurisdiction where IPC §903.2 applies, a vent extension through the roof must be at least:
- a.1-1/4 inches in diameter
- b.6 inches in diameter
- c.2 inches in diameter
- d.3 inches in diameter✓
Where the design temperature is below 0°F, vent extensions through the roof are at least 3 inches so that frost does not close the opening, with any increase made at least 1 foot inside the building's thermal envelope. Most of Texas is above that threshold.IPC §903.2
A sidewall vent terminal is allowed under IPC §903.6 only where it is at least:
- a.5 feet from the lot line and 7 feet above the highest adjacent grade
- b.25 feet from the lot line and 20 feet above the highest adjacent grade
- c.3 feet from the lot line and 1 foot above the highest adjacent grade
- d.10 feet from the lot line and 10 feet above the highest adjacent grade✓
Vent terminals through a wall are at least 10 feet from the lot line and 10 feet above the highest adjacent grade within 10 feet horizontally, are protected against birds and rodents, and do not terminate under an overhang with soffit vents.IPC §903.6
Under IPC §904.2, a vent stack is required for a drainage stack that has:
- a.Ten or more branch intervals
- b.Five or more branch intervals✓
- c.Two or more branch intervals
- d.Three or more branch intervals
Every drainage stack of five branch intervals or more needs a vent stack, connected at or below the lowest branch. Shorter stacks rely on the stack vent. Ten branch intervals is where relief vents come in.IPC §904.2
Under IPC §904.1, every building's sanitary drainage system must have at least one vent that:
- a.Is 4 inches in diameter
- b.Ends in the attic space
- c.Has an air admittance valve
- d.Extends to the outdoors✓
At least one vent pipe must extend to the outdoors, so that positive pressure in the system can be relieved; air admittance valves only admit air. Attic termination is prohibited, and no fixed 4-inch size applies.IPC §§904.1, 918.7
A lavatory and a kitchen sink on opposite sides of a wall connect at the same level to a vertical drain and share one vent. Under IPC §911, this is:
- a.A common vent✓
- b.A wet vent
- c.A circuit vent
- d.A relief vent
An individual vent serving two fixture drains is a common vent; when the drains connect at the same level, the vent rises from their intersection. Circuit vents serve a battery of fixtures, wet vents carry waste, and relief vents equalise pressure on stacks.IPC §911.1
Two fixtures connect to a vertical drain at different levels and share a common vent. Under IPC §911.2, the upper fixture may NOT be:
- a.A drinking fountain
- b.A water closet✓
- c.A lavatory
- d.A bathtub
Where fixture drains connect at different levels, the vertical pipe between them is the vent for the lower fixture, and the upper fixture may not be a water closet, whose discharge would fill the pipe. Lavatories, tubs and fountains are acceptable upper fixtures within the fixture unit limits.IPC §911.2
Under IPC §912.1, a horizontal wet vent may serve any combination of fixtures within:
- a.Four bathroom groups located on two adjacent floor levels
- b.Any number of bathroom groups on the same floor level
- c.One bathroom group and one kitchen on the same floor level
- d.Two bathroom groups located on the same floor level✓
Horizontal wet venting covers fixtures within one or two bathroom groups on the same floor level. Kitchen sinks, fixtures on other floors and larger groupings fall outside the method.IPC §912.1
A horizontal wet vent serves a bathroom group. Under IPC §912.2, the dry vent for the wet-vented section may connect to:
- a.Any bathroom group fixture drain, except that of an emergency floor drain✓
- b.The building drain at any point downstream of the wet-vented section
- c.A kitchen sink drain located on the floor above the bathroom group
- d.The water closet fixture drain only, and to no other fixture in the group
The required dry vent is an individual or common vent for any bathroom group fixture other than an emergency floor drain. It need not be at the water closet, and a connection from another floor or downstream of the wet vent does not vent the section.IPC §912.2
Under IPC §912.3, a 2-inch wet vent may carry a drainage load of no more than:
- a.1 drainage fixture unit
- b.12 drainage fixture units
- c.8 drainage fixture units
- d.4 drainage fixture units✓
The wet vent size table allows 1 dfu on 1-1/2 inch, 4 dfu on 2 inch, 6 dfu on 2-1/2 inch and 12 dfu on 3 inch. The dry vent connecting to it is sized for the largest required drain in the wet vent.IPC §912.3
Under IPC §914.1, one circuit vent may serve a battery of no more than:
- a.12 fixtures connected to a horizontal branch drain
- b.24 fixtures connected to a horizontal branch drain
- c.8 fixtures connected to a horizontal branch drain✓
- d.4 fixtures connected to a horizontal branch drain
A circuit vent serves up to eight fixtures on a horizontal branch; each fixture drain connects horizontally to the branch, which is treated as a vent for its length. Larger batteries need more than one circuit.IPC §914.1
Under IPC §914.2, the circuit vent connection to the horizontal branch is made:
- a.Downstream of the last fixture drain on the branch
- b.At the base of the stack that the branch joins
- c.Upstream of the first fixture, at the cleanout
- d.Between the two most upstream fixture drains✓
The circuit vent takes off between the two upstream-most fixture drains so that the branch itself, washed by the first fixture, serves as a vent for the rest. A downstream or stack connection is a relief vent, not the circuit vent.IPC §914.2
Under IPC §914.3, the slope of a circuit-vented horizontal branch may not exceed:
- a.1 inch per foot✓
- b.1/8 inch per foot
- c.1/4 inch per foot
- d.2 inches per foot
The circuit-vented branch is sized as a horizontal branch and its slope is limited to 1 unit vertical in 12 horizontal, so that air can move above the flow. The smaller figures are minimum drain slopes, not the maximum.IPC §914.3
Under IPC §915.1, a combination waste and vent system may serve only:
- a.Water closets, urinals, bidets and clinical sinks
- b.Floor drains, sinks, lavatories and drinking fountains✓
- c.Food waste disposers, floor sinks and mop sinks
- d.Bathtubs, showers, clothes washers and domestic dishwashers
Combination waste and vent systems are limited to floor drains, sinks, lavatories and drinking fountains, and they may not receive the discharge of a food waste disposer or clinical sink. Water closets and urinals are never served by this method.IPC §915.1
An island kitchen sink is vented under IPC §916. Before the vent turns down to run below the floor, it must rise:
- a.To the underside of the roof deck above the island
- b.Above the drainage outlet of the fixture being vented✓
- c.To 42 inches above the finished floor of the kitchen
- d.Only to the level of the trap weir of the sink
The island fixture vent rises vertically above the drainage outlet of the fixture before offsetting horizontally or downward, and cleanouts allow the vent to be rodded. It does not have to reach the roof deck at that point or a fixed 42-inch height.IPC §916.2
Under IPC §916.1, island fixture venting is permitted for:
- a.Bathtubs and showers
- b.Sinks and lavatories✓
- c.Water closets and urinals
- d.Floor drains and floor sinks
Island venting is limited to sinks and lavatories; a residential kitchen sink with a dishwasher connection or disposer is included. Other fixtures are vented by the standard methods.IPC §916.1
An individual air admittance valve is installed under a kitchen sink. Under IPC §918.4, it must be located at least how far above the horizontal branch drain or fixture drain it vents?
- a.42 inches
- b.1 inch
- c.12 inches
- d.4 inches✓
Individual and branch-type air admittance valves are at least 4 inches above the horizontal branch drain or fixture drain being vented. Stack-type valves are at least 6 inches above the flood level rim of the highest fixture.IPC §918.4
A stack-type air admittance valve terminates a vent stack. Under IPC §918.4, it must be at least how far above the flood level rim of the highest fixture being vented?
- a.4 inches
- b.1 inch
- c.6 inches✓
- d.36 inches
Stack-type valves are set at least 6 inches above the flood level rim of the highest fixture vented; valves in attics sit at least 6 inches above insulation. Four inches is the figure for individual and branch-type valves above the drain.IPC §918.4
Under IPC §918.5, an air admittance valve must be installed:
- a.In the crawl space, below the level of the fixture trap
- b.In an accessible location with ventilation that lets air enter the valve✓
- c.In a sealed wall cavity where it is protected from tampering and from dust
- d.In a supply or return air plenum so that it is kept warm
The valve must be accessible for replacement and located in a ventilated space so that it can draw air. It may not be sealed in, placed in an air plenum, or installed below the drain it vents.IPC §§918.4, 918.5
Which statement about air admittance valves is correct under IPC §918?
- a.They may replace every vent to the outdoors in a one-story building
- b.They admit air on negative pressure but cannot relieve positive pressure✓
- c.They may be used to vent sewage ejector sumps of any capacity
- d.They relieve positive pressure but cannot admit air on negative pressure
An air admittance valve opens on negative pressure and closes by gravity, so it cannot vent positive pressure; that is why at least one vent must still extend outdoors. Sumps need open vents unless an engineered design is approved.IPC §918
A drainage stack serves 22 branch intervals. Under IPC §908.1, a relief vent between the drainage stack and the vent stack is required:
- a.At each tenth branch interval, counted from the top floor✓
- b.At each second branch interval, counted from the top floor
- c.At the base of the stack only, below the lowest branch
- d.At the roof only, where the two stacks join in a header
Stacks of more than 10 branch intervals have a relief vent at each tenth interval, starting from the top floor, to equalise pressure in tall stacks. A base connection alone does not relieve mid-height pressure zones.IPC §908.1
Under IPC §905.6, where a drain is roughed in for a future fixture, the vent provided for it must be at least:
- a.3 inches, whatever the size of the drain
- b.One-half the diameter of the roughed-in drain✓
- c.The same diameter as the roughed-in drain
- d.One-quarter the diameter of the roughed-in drain
A vent of at least half the diameter of the rough-in drain is installed and labelled or connected to the vent system. Quarter size is inadequate, and full size or 3 inches is not required.IPC §905.6
A "stack vent" is:
- a.A pipe that connects several vents and extends as one to the outdoor air
- b.The extension of a soil or waste stack above the highest horizontal drain connected to it✓
- c.A vent that also receives the discharge of fixtures other than water closets
- d.A vertical vent pipe installed alongside a drainage stack to circulate air to its branches
The stack vent is the dry extension of the drainage stack above the top branch. A separate vertical vent run with the stack is a vent stack, a vent that carries waste is a wet vent, and a pipe gathering several vents is a vent header.IPC §202
During the practical examination, candidates lay out a two-story DWV system. Under IPC §913.2, a waste stack vent (a stack that vents the fixtures connected to it) must be:
- a.Used only for water closets and urinals, with other fixtures separately vented
- b.Vertical, with no offsets between its lowest and highest fixture drain connections✓
- c.At least 6 inches in diameter, regardless of the fixture unit load that it carries
- d.Offset at each floor, so that waste from the floor above slows down on its way
A waste stack used as a vent must be vertical with no offsets between the lowest and highest fixture drain connection, and water closets and urinals may not discharge to it. Its size comes from the waste stack vent table, not a fixed 6 inches.IPC §913.2